QVS2GPFOB232
ALTER SMARTVISION
2’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT
2 LAMP, T8, 5 1/2” DEEP
MICROPERFORATED MESH LAMP SHIELD
STATIC
Efficiency 58.4%.
Broadcast 4: Broadcast control requires no programming of
the iGEN ballasts. Dimming message are sent with a global
address from the master Alter Smart Vision luminaire
to up to 3 slaves luminaire with an iGEN address able
ballast (DA). Each ballast receives the same command and
responds unifomity.
Swing down microperforated lamp shield for easy
relamping and maintenance.
Lamp shield specially cut to accomodate Smart
Vision sensor.
Alter soft white film on inside of mesh conceals lamp
image providing balance between reflected and
direct light.
Fully recessed luminaire and lamp compartment.
95% Reflective Alter soft white paint finish.
Specular interior reflector.
One piece body for easy installation.
Easy access to ballast through lamp
compartment.
Fits standard T-Grid ceilings.
Optional acrylic drop-down visual element.
MOUNTING METHODS/FEATURES DIMENSIONS
Ceiling compatibility
Suited to standard exposed T-grid ceilings
Swing down optical system for
easy relamping and maintenance
Microperforated mesh lamp shields
Suited to standard exposed Slot T-grid ceilings
integrated motion and light sensor with
optional dimming infrared remote control
FIXTURE TYPE
Genlyte Thomas Company
VOLTS
L30-80
JOB INFORMATION:
QVS2GPFOB232
ALTER SMARTVISION
2’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT
ORDERING INFORMATION Explanation of Catalogue Number Example: QVS2GPFOB232120DS
QVS
QUALITY
VISUAL
STATIC
Recessed direct
indirect soft light
optical system
SPECIFICATIONS
MATERIALS: One piece chassis constructed from die formed
20 gauge cold rolled steel. Reflectors - 95% reflectance baked white
acrylic matte paint finish. Specular interior reflector. Soft white acrylic film
on inside of lamp shield conceals lamp image.
FINISH: Chassis exterior - phosphate undercoating, baked white acrylic
matte high reflectance paint finish.
2
FIXTURE
WIDTH
2’
G
CEILING
TYPE
Standard exposed
T-grid ceilings
PF
LAMP
SHIELD
PF =Microperforated
OB 2 32
LAMP SHIELD DETAILS
OB = One-piece lamp shield
with sensor
LAMP
QUANTITY
ELECTRICAL: Rapid start HPF, thermally protected class “P” ballast (Bi-tube
type). If K.Os are within 3” of ballast use wire suitable for at least 90C.
LABELS: Listed by CSA, UL
LAMP/FIXTURE
LENGTH
(NOMINAL 24”)
32 = 32W T8
120
VOLTAGE
120V
DS
BALLAST TYPE
DS = iGEN Broadcast 4 Sensor/ iGEN
ballast*
* For other voltage, consult your
Lightolier representative.
OPTIONS
R =Radio Interface Filter
O =Emergency Lighting
System (for Canada)
N =Emergency Lighting
System (for U.S.)
We reserve the right to change, materials and finish in any way that will not alter installed appearance or reduce function and performance.
631 Airport Road, Fall River, MA 02720 - Tel. (508) 679-8131
C.F.I. Division of Canlyte, Inc.
525 Education Road, Cornwall, Ontario
Canada K6H 6C7 - (613) 938-6221