ALTER HIGH EFFICIENCY QHE2GPFOP232 OR 332
QVA2GSDOS2FT
Page 1 of 2
2’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT 2 OR 3 LAMP, T8
5-1/2'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC
Features
• Efficiency 64.3% (3 lamp T8).
• Swing down microperforated lamp shield for easy relamping and maintenance.
• Alter soft white film on inside of mesh conceals lamp image and provide balance between reflected light and direct light.
• 95% Reflective Alter soft white paint finish.
• Specular interior reflector.
• One piece body for easy installation.
• Easy access to ballast through lamp compartment.
• Fits standard T-Grid ceilings.
Mounting Methods / Features
Ceiling compatibility
Dimensions
Suited to standard exposed T-grid ceilings
Microperforated mesh lamp shield
Suited to standard exposed Slot T-grid ceilings
Job Information
Job Name: Cat. No.:
Lamp(s): Volts/Ballast:
Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L30-32
Type:
®
LIGHTING SCIENCES CANADA LTD. 440 PHILLIP ST., UNIT 19 WATERLOO, ONTARIO
CERTIFIED TEST REPORT NO. LSCA017 COMPUTED BY LSC PROGRAM **TEST-LITE**
LIGHTOLIER-CFI 2x4 RECESSED LUMINAIRE CAT. NO. QVS2GPFOP332120O3 SILVER BALL. COVER, WHITE REFLECTOR, PERF.LAMP SHIELD, WHITE OVERLAY THREE F32T8/TL841 32W T8 FLUORESCENT LAMPS. LUMEN RATING = 2950 LMS. ONE ADVANCE 120V 2 OR 3-LAMP ELECTRONIC BALLAST NO. REL-3P32-SC
COEFFICIENTS OF UTILIZATION
ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
CC 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0 .77 .77 .77 .77 .75 .75 .75 .75 .71 .71 .71 .68 .68 .68 .66 .66 .66 .64
1 .70 .67 .65 .63 .69 .66 .64 .62 .63 .61 .60 .61 .59 .58 .59 .57 .56 .55
2 .64 .59 .55 .52 .63 .58 .54 .51 .56 .53 .50 .54 .51 .49 .52 .50 .48 .46
3 .59 .52 .47 .43 .57 .51 .47 .43 .49 .46 .42 .48 .44 .41 .46 .43 .41 .39
4 .54 .46 .41 .37 .53 .46 .41 .37 .44 .40 .36 .43 .39 .36 .41 .38 .35 .34
5 .49 .41 .35 .31 .48 .40 .35 .31 .39 .34 .31 .38 .33 .30 .36 .33 .30 .28
6 .45 .37 .31 .27 .44 .36 .31 .27 .35 .30 .26 .34 .29 .26 .33 .29 .26 .25
7 .42 .33 .27 .23 .41 .32 .27 .23 .31 .26 .23 .30 .26 .23 .30 .26 .23 .21
8 .38 .29 .24 .20 .37 .29 .24 .20 .28 .23 .20 .27 .23 .20 .26 .23 .20 .18
9 .35 .27 .21 .17 .34 .26 .21 .17 .25 .20 .17 .25 .20 .17 .24 .20 .17 .16
10 .33 .24 .19 .15 .32 .24 .19 .15 .23 .18 .15 .22 .18 .15 .22 .18 .15 .14
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES LUMINAIRE INPUT WATTS = 84.5 LABORATORY RESULT MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST FACTORS HAVE NOT BEEN APPLIED.
ALTER HIGH EFFICIENCY QHE2GPFOP232 OR 332
Page 2 of 2
2’ X 4’ RECESSED DIRECT/INDIRECT FLUORESCENT 2 OR 3 LAMP, T8
QVA2GSDOS2FT
QVA2GSDOS2FT
5-1/2'' DEEP MICROPERFORATED MESH LAMP SHIELD, STATIC
Photometry
CERTIFIED TEST REPORT NO. LSCA017 COMPUTED BY LSC PROGRAM **TEST-LITE**
LIGHTOLIER-CFI 2x4 RECESSED LUMINAIRE CAT. NO. QVS2GPFOP332120O3 SILVER BALL. COVER, WHITE REFLECTOR, PERF. LAMP SHIELD, WHITE OVERLAY THREE F32T8/TL841 32W T8 FLUORESCENT LAMPS. LUMEN RATING = 2950 LMS. ONE ADVANCE 120V 2 OR 3-LAMP ELECTRONIC BALLAST NO. REL-3P32-SC
CANDLEPOWER SUMMARY OUTPUT LUMENS ANGLE ALONG 22.5 45 67.5 ACROSS 0 1916 1916 1916 1916 1916 5 1915 1927 1915 1909 1905 185 10 1897 1892 1892 1884 1883 15 1845 1856 1853 1860 1858 522 20 1780 1793 1796 1811 1813 25 1697 1715 1740 1741 1762 797 30 1606 1624 1652 1680 1689 35 1494 1520 1564 1596 1617 973 40 1367 1399 1456 1507 1537 45 1224 1265 1337 1400 1429 1027 50 1061 1121 1210 1288 1319 55 911 972 1074 1160 1195 951 60 735 817 934 1012 1041 65 582 666 786 837 847 739 70 431 525 616 625 615 75 296 369 396 399 411 402 80 169 220 203 231 241 85 54 56 75 74 80 91 90 0 0 0 0 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE 0-30 1503 16.99 26.44 0-40 2477 27.99 43.56 0-60 4455 50.34 78.34 0-90 5687 64.26 100.00 40-90 3209 36.27 56.44 60-90 1232 13.92 21.66 90-180 0 .00 .00 0-180 5687 64.26 100.00
** EFFICIENCY = 64.3% **
LUMINANCE SUMMARY-CD. / SQ. M. PAINT REFLECTANCE = .92 S/MH = 1.3 SC(ALONG) = 1.2, SC(ACROSS) = 1.3
ANGLE ALONG 45 ACROSS CERTIFIED BY: 45 2482 2720 2908 DATE: 55 2278 2694 2999 DEC 4, 2003 65 1975 2674 2885 PREPARED FOR: 75 1640 2197 2285 LIGHTOLIER-CFI 85 883 1240 1326 CORNWALL, ONTARIO
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
Model No. : QHE2GPFOP33212003
Ordering Information Explanation of Catalogue Number Example: QHE2GPFOP33212003
QHE G23OP 32
QUALITY
HIGH
EFFICIENCY
Recessed direct indirect soft light high efficiency optical system
SPECIFICATIONS
MATERIALS: One piece chassis constructed from die formed 20 gauge cold
rolled steele. Reflectors - 95% reflectance baked white acrylic matte paint finish. Specular aluminum interior reflector. Soft white acrylic film on inside of lamp shield conceals lamp image. FINISH: Chassis exterior - phosphate undercoating, baked white acrylic matte paint finish. ELECTRICAL: Rapid start HPF, thermally protected class “P” ballast (Bi-tube type). If K.Os are within 3” of ballast use wire suitable for at least 90C.
LABELS: Listed by CSA, UL
FIXTURE
WIDTH
2'
CEILING TYPE
Standard exposed T-grid ceilings
LAMP SHIELD
PF = Microperforated
LAMP SHIELD
DETAIL
OP = One piece
(no center slot)
LAMP
QUANTITY
2 3
OPTIONS
R = Radio
Interference Filter O = Emergency Lighting System (for Canada) N = Emergency Lighting System (for U.S.)
LAMP/FIXTURE
LENGTH
(NOMINAL 48'')
32 = 32W T8
VOLTAGE
120V 277V 347V
BALLAST OC = Magnetic T8 03 = Electronic T8 instant start 3LPB* R3 = Electronic rapid start 3LPB* PS = PowerSpec HDF Dimming T8
* LPB: Lamp per ballast
Type:Job Information
Lightolier a Genlyte Thomas Company Technical Information: (978) 657-7600 - (978) 658-0595 631 Airport Road, Fall River, MA 02720 - (508) 679-8131 C.F.I. Division of Canlyte, Inc. 525 Education Road, Cornwall, Ontario, Canada K6H 6C7 - (613) 938-6221 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 5 / Folio L30-32
®