3. Insulated liner : .040” wall, high temperature extruded thermoplastic.
4. Toggle Bolts and Screws: furnished with track unit.
5. Dead End Cap: molded thermoplastic.
Mechanical
Track units plug together and lock securely to prevent accidental separation.
ProSpec™ track fix tures can be attached at any point along the track. Track units
may be field cut.
Electrical
(2) circuits. Each circuit is 277V, 60Hz, 20 AMP compatible. Each circuit has
dedicated neutral for maximum control flexibility. Track units are continuously
grounded throughout. Electrical conductors are concealed in an insulated liner
in the track. Intended for wiring to branch circuit building wire with ground, in
accordance with National and local codes.
Finish
All painted finishes are baked enamel.
Label
cUL us, I.B.E.W
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
3/8” Standof f Clips, order separately. Recommended
2 clips per 4’, 3 clips per 8’, 4 clips per 12’ track units.
Use additional clips for more suppor t in high load
applications. Toggle bolts are included.
Not recommended for wall mounting.
26478 WH Matte White (4) per pack.
26478BK Matte Black (4) per pack.
3/8"
Direct Mounting
Mount through existing holes in track. Top of track
sits flush to ceiling.
Recommended for wall and ceiling mounting.
Toggle Bolt
Nylon Spacer
Screw
1/16" Flush Mount Clips
Nylon coated spring steel. Spaces track 1/16” from
ceiling. Recommended 2 per 4’, 3 per 8’, and 4 per 12’
track sections. Use additional clips for more support
when track is heavily loaded. Clips may be ordered
separated.
Not recommended for wall mounting.
56451WH Matte White (set of 10)
56451BK Matte BK (set of 10)
Grid Ceiling Mounting Clips
Square Edge Panels and 9/16” - 15/16” T-Bars Clip
is supplied assembled. Mounts easily onto T-Bars by
rotating clips. Use t wo per 4’ track, three per 8’ and
12” track.
6089 (9) Clips
T-Runner
Square
Edge Panel
9/16" - 15/16"
Regres sed Edge Panels
9/16” - 15/16” T-Bars
Clips or supplied assembled. Mounts easily onto
T-Bars by rotating clips. Use two per 4’ track, three
per 8’ and 12’ track.
6087 (9) Clips
9/16"
15/16"
6088 (9) Clips
1/8" &
T-Runner
1/4"
9/16"
Grid Ceiling Canopy Kit (End & Floating)
For mounting the track to grid suspended ceilings.
Mounts to ceiling types shown above using clips
6087, 6088, or 6089 which are ordered separately.
Includes a special outlet box to fit onto runners.
Power can be fed to Feed Track, Live End, “L”, “T”,
“X”, In-Line connectors and Powertrip canopy version. Mounts along runner or at the intersection of
runners.
T-Bar Mounting Clip
Live End Connector
26096WH Matte White
Job Information Type:
Regressed
Edge Panel
Slotted Grid
Runner
5/16"
4" Octagon
Outlet Box
(by others)
T-Bar
Track
Surface Canopy Kit (End)
Canopy can be mounted directly over the live end,
in-line, ‘L’, ‘T’, and ‘X’ connectors. Canopy also can
be positioned anywhere on the track up to 4' from
edge of the track extrusion (floating feed, wire
cover included). Power can be fed into live end and
Powertrip only utilizing the floating feed option.
Canopy mounts to a 4” octagonal outlet box. Use
1/16” flush mounting clips (supplied with track) or
direct mount to ceiling or wall.
4" Octagon
Outlet Box
(by others)
Square Canopy
Live End
or Connector
Track
1/16" Flush
Mounting Clip
26060WH Matte White
26060BK Matte Black
Standoff Canopy Kit (End)
For use with 26478WH, BK 3/8” standoff mounting
clips (ordered separately). Canopy can be mounted
directly over the live end, in-line, ‘L’, ‘T’, and ‘X’ connectors. Canopy also can be positioned anywhere on
the track up to 4' from edge of the track extrusion
(floating feed, wire cover included). Power can be fed
into live end and Powertrip only utilizing the floating
feed option. Canopy mounts to a 4” octagonal outlet
box. Use 1/16” flush mounting clips (supplied with
track) or direct mount to ceiling or wall.
Mounts to a 4” Octagon outlet box or surface.
Use two per 4’ track, three per 8’ and 12’ track.
When making a run of track do not exceed 4’
between stems. Use additional stems for additional support.Can feed live end only. 8ft maximum length of suspension. Stem can be field cut.
Not recommended for wall mounting.
18” Stem 48” Stem
Actual length for ceiling to top of track:
17 3/8” 47 3/8”
Matte White 7584 7586
Matte Black 76 83 7681
3" or 4" Octagon
Outlet Box
(by others)
This end may be
field cut.
Stem 1/4"-18
NPSM Thread
Clamp Set
Swivel Stem Mounting Kits
Adjusts from 0° to 90°. Can be field cut. 48”
stem. 8' maximum length of suspension. Can
feed live end only. Stem can be field cut.
7480 Matte White
7481 Matte Black
Stem Extension Kit
Mounts to any system kit to extend its length to 48”.
Cannot be field cut.
7582 Matte White
7680 Matte Black
Stem Extension
1/2" O.D. Steel
Tube
1/4 - 18 NPSM
Thread.
Clamp Set
Powerfeed Cord 10'
To be used with stems or
cables. (3) 12ga wires and
(1) 12ga ground. Fiber glass
.295"
jacket white or black. Can
be field shortened. Not a
mechanical support. Can
feed into all connectors.
37 310WH White
37 310BK Black
Cable Suspension Kit
Maximum distance
between suspension
cables is 8ft.
Feeds power at either end of track. Not polarized.
Can be fed directly from surface or from ceiling using
a 3/8” or 1/2” electrical connector (by others).
(3) 12ga wires and (1) 12ga ground. Fiber glass jacket
white or black. Can be field shortened. Can feed into
all connectors.
370 05WH/BK ProSpec 277V, 2 Circuit, 20A Power
Feed for Suspended Mtg. 5', White/Black
37010W H/ BK ProSpec 277V,
2 Circuit, 20A Power Feed for
Suspended Mtg. 10', White/Black
370 20WH/BK ProSpec
277V, 2 Circuit, 20A Power
Feed for Suspended
Mtg. 20', White/Black
Job Information Type:
.062 Dia
Steel Cable
Through Wall or Column
Track
Live End
Connector
Wall
Jump (Conduit)
Track
Live End
Connector
Page 4
ProSpec
™
277V Track Lighting 37000
Page 4 of 4 Track
Feed Connections for Surfac e, Cable an d Stem Moun ted Patterns
All connectors can be fed directly from above using a 3/ 8” or 1/2” electrical connector (by others).
“L” Connector
The “L” connector is pre-wired.
Not polarized.
370 50WH Matte White
370 50BK Matte Black
“T ” Connector
The “T” connector is not pre-wired or
polarized. Used to make “T” pattern with
track. 12ga. copper jumper wires supplied
to make all necessar y connections.
370 51WH Matte White
370 51BK Matte Black
3.59"
5 1/4"
4.18"
3.59"
GND
NEUT
NEUT
5 1/4"
Extruded Aluminum Housing
10 9/16"
See Detail A
Typ. for all Track
Connections
3.59"
GND
7 3/16"
NEUT
NEUT
See Detail A
Typ. for all Track
Connections
Invisible Coupler
Used to connect t wo pieces of track together
mechanically and electrically. Power cannot be feed
into the mini-coupler.
370 49WH Matte White
370 49BK Matte Black
Detail A
Use 12ga. solid copper wire for feed
connections including ground.
Extrude d Aluminum Ho using
“X” Connector
The “X” connector is not pre-wired. Used to make
“X” pattern with track. 12ga. copper jumper wires
supplied to make all necessar y
connections. Not polarized.
370 52WH Matte White
370 52BK Matte Black
7 3/16"
3.59"
Extruded Aluminum Housing
In-Line Connector
Permits power feed-in between
track units in a straight run of
track. The “In-Line” connector