Lightolier PNB 232, PNB 132, PNB 332 User Manual

PRISMALYTE (PNB) PNB SERIES 132/232/332
Page 1 of 2 1'x4' SURFACE BOX FLUORESCENT, PREMIUM SPECIFICATION GRADE LENSED
1, 2, OR 3 LAMP T8/T12
FEATURES
MOUNTING METHOD
DIMENSIONS
Job Information Type:
Job Name:
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 3A/Folio H50-16 REV. A
Features
• Only 5-1/2" deep.
• Efficiency 58.4% (2 lamp T8).
• 1.2 spacing mounting ratio (2 lamp T8).
• 20 gauge steel body.
• 45° mitered corners (body and door frame).
• Side mounted ballast for cooler operation.
• Fully enclosed wiring.
• Available in three lens frame styles.
• Door jamb with positive light stop.
• Spring-loaded latches.
• Reversible door frame hinge.
• Available with floating or full size doors.
• Matches Prismalyte (PRA/PRS) recessed.
• Frames interchangeable with Deepcell (DPB).
• Meets NYC Code requirements.
(FA) flat full-size aluminum frame.
(RA) regressed full-size aluminum frame.
(FS) flat full-size steel frame.
(RF) 1/2" regressed floating aluminum frame.
4"
(102mm)
48" (1219mm)
1-3/16" (30mm)
2"
(51mm)
20"
(508mm)
9/32" mounting hole
3/16" x 5/8" K.O.
5-7/8"
(149mm)
12"
(305mm)
7/8" dia. K.O. within 1-7/8" dia. K.O.
12" (305mm)
5-1/2"
(140mm)
Stem mounting (four per fixture is required)
PRISMALYTE (PNB) PNB SERIES 132/232/332
Page 2 of 2 1'x4' SURFACE BOX FLUORESCENT, PREMIUM SPECIFICATION GRADE LENSED
1, 2, OR 3 LAMP T8/T12
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 3A/Folio H50-16 REV. A
Job Information Type:
OPTIONS & ACCESSORIES
FUSING: Internal fast-blow fusing.
SUFFIX: GLR. Internal slow-blow fusing.
SUFFIX: GMF. RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF.
ELECTRICAL/WIRING OPTIONS Consult factory. STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface. (Four per fixture is recommended.) Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24")
SPECIFICATIONS
PERFORMANCE: In an installation of 2 lamp 32W luminaires in a room cavity
ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .63. To prevent glare the VCP shall not be less than 55 either length­wise or crosswise (at 100 fc level) and the average brightness at 65° shall not exceed 647 footlamberts. To control veiling reflections, luminaire output in the 30° - 90° zone shall be not less than 63.5%.
SPECIFICATIONS (continued)
MATERIALS: Chassis parts are die-formed 20 gauge cold rolled steel, stud-
welded for rigidity. Lens Frame—(FA) flush full-size aluminum frame, (FS) flush full-size steel frame, (RA) regressed full-size aluminum frame, (RF) 1/2" regressed floating aluminum frame with 7/16" black reveal, four sides. FINISH: Chassis exterior—white baked acrylic enamel. Cavity—white baked acrylic enamel minimum reflectance 86%. Phosphate undercoating. Lens—extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge, .095" nominal thickness (similar to pattern 12). ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.
PHOTOMETRY MODEL NO. PNB1SFAVA232120SO
ORDERING INFORMATION Explanation of Catalog Number. Example: PNB1SFAVA232120SOGLR
PN
PRISMALYTE :
Lens Frame
Surface
Fluorescent
B
BODY STYLE:
Surface Box
1
FIXTURE
WIDTH
S
CEILING
TYPE:
S=Surface
LENS FRAME:
FA= Flush full-size
aluminum frame
FS=Flush
full-size steel frame
RA=Regressed
full-size aluminum frame
RF*=1/2"
regressed floating aluminum frame
LENS/
SHIELDING
TYPE:
VA=Virgin
acrylic (standard) See specifications and consult factory
LAMP
QUANTITY:
(By Others)
1=1 Lamp 2=2 Lamp 3=3 Lamp
LAMP/
FIXTURE LENGTH:
32=T82 34=T12
(Nominal 48")
VOLTAGE:
120 or 277
OPTIONS:
Add
appropriate
suffix to
catalog no.,
ie: (GLR)
*With 7/16" black reveal four sides.
coefficients of utilization — zonal cavity method
RF 20 20 20 RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1656361 595756 575554 2605653 535149 514948 3565147 484543 474442 4524642 444038 434037 5484137 403633 393533 6453833 363229 353229 7413430 332926 322826 8383126 302623 292523 9352823 272320 262320
10 33 25 21 25 21 18 24 20 18
visual comfort probability
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 68 71 77 80 68 72 77 81
20 30 61 64 68 72 62 65 69 73 20 40 58 60 64 66 58 61 64 67 20 60 55 57 60 62 55 58 60 62
30 20 69 73 77 80 69 73 77 80 30 30 62 65 69 72 62 65 69 72 30 40 58 60 63 65 58 61 63 66 30 60 54 57 58 61 54 57 59 61 30 80 53 55 55 58 53 55 56 58
40 20 71 74 78 81 71 74 79 81 40 30 63 66 70 73 63 66 70 73 40 40 58 61 64 66 59 61 64 66 40 60 54 57 58 60 55 57 59 61 40 80 53 55 55 57 53 55 56 58 40 100 52 53 54 55 52 54 54 56
60 30 64 67 70 73 64 67 71 73 60 40 59 62 64 67 59 62 64 67 60 60 55 57 58 61 55 57 58 61 60 80 52 54 55 57 52 54 55 57 60 100 51 53 53 55 51 53 53 55
100 40 62 64 66 69 62 64 66 69 100 60 57 59 60 62 57 59 60 63 100 80 54 55 56 58 54 56 56 58 100 100 52 53 53 55 53 54 54 55
room cavity ratio
luminaries lengthwise
luminaries crosswise
PNB1SFAVA232120SO
ALUMINUM FRM & VIRGIN ACRYLIC LENS
BALLAST TYPE:
1 & 2 Lamp Mag. T12 LE
<20THD <10THD
1 & 2 Lamp Elec. T8 SO* H
I*
1-3 Lamp Elec. T8 O3* H3* 1-2 Lamp Elec. T8 SO* H
I*
LOL Dimming T8 PS – *Instant Start Standard
Other dimming options. Consult factory.
F32/T8
2850
Loading...