Lightolier PLA2G120SO, PLA2G16LS26U User Manual

Dimensions
Paralyte 2424 PLA2G16LS26U
Page 1 of 2 2' x 2' Recessed Fluorescent, 3-1/8" Deep, 16 Cell Parabolic Louver
Static and Air Return 2 Lamp, T8 or T12
Job Information Type:
Job Name:
Cat. No.:
Volts/Ballast:
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2003 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 2/Folio G50-53 Rev. A
Features
• 23” x 23” louver
• Efficiency 59.3%.
• One fixture fits 50 different G type and T type ceiling systems.
• Only 5 1/2” deep housing.
• Automatic engaging adjustable seismic clips.
• Pre-anodized aluminum vertical grain parabolic louver.
• 3 1/8” deep louver.
• Low iridescence semi-specular aluminum, standard.
• Spring-loaded latches.
• Protective film dust guard.
• UL-Listed twin knockout access plate.
• Not for continuous row mounting.
NOTE: Fixtures may be used for static or air return applications.
24" (610mm)
5-1/2"
(140mm)
slot grid
two-directional concealed grid
narrow grid system
standard grid
Adjustable seismic clip (patented)
Adjustable seismic clip (patented)
*1-1/2"
*1-1/2"
Adjustable seismic clip (patented)
*1-1/2"
Adjustable seismic clip (patented)
Mounting Methods
*If less than 1 1/2”, STC spacer is required, 2 each end.
air return capabilities exceed standard requirements (see Folio G50-50)
4/03
24" (610mm)
3" x 3" access plate with two K.O.’s (7/8" dia.)
24"
(610mm)
8-7/8"
(225mm)
c
L
Paralyte 2424 PLA2G16LS26U
Page 2 of 2 2' x 2' Recessed Fluorescent, 3-1/8" Deep, 16 Cell Parabolic Louver
Static and Air Return 2 Lamp, T8 or T12
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2003 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 2/Folio G50-53 Rev. A
Job Information Type:
Options & Accessories
Prewiring: 3/8” factory prewired cable (three no. 18 AWG leads, 6’ long), Suffix: FF6, (Four no. 18 AWG leads, 6’ long), Suffix: FF14. Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF.
Fluorescent Emergency Lighting System: Factory-installed emergency power
battery pack with charger and inverter, concealed in fixture channel. Operates one fluorescent lamp at reduced light output for 90 minutes. Suffix: EM. Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture. Suffix: R. One per ballast. Suffix: B. Electrical Options: Special wiring, fusing or dimming ballasts and installed lamps are available, consult your Lightolier representative or factory. T-Bar Spacer: If T-bar is less than 1-1/2” deep, order Catalog Number: STC. 2 each end is required.
Specifications
Performance: In an installation of 2 lamp 31W Iuminaires in a room cavity ratio
of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U shall not be less than 64. To prevent glare the VCP shall not be less than 88 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 206 foot-Iamberts. To control veiling reflections, luminaire output in the 3C°-90° zone shall not be less than 68.6%.
Specifications (continued)
Air Return: Designed to provide optimum air return. Air is returned through the
lamp compartment for all ceiling systems and direct to plenum through slots in slot grid and narrow grid ceiling systems. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is embossed for rigidity with all edges turned up for safe handling. Louver is pre-anodized aluminum (Coilzak®or equal). Finish: Louver–semi-specular anodized low iridescence, vertical grain reflector sheet. Cavity–white baked polyester minimum 86% reflectance. Phosphate undercoating. Chassis exterior–black baked polyester enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3” of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
Photometry Model No. PLA2G16LS26U120SO
PL
Paralyte
2424:
3-1/8" Deep
Parabolic Precision
Contoured Pre-
anodized
Aluminum
Louver
A
Body Style:
A=Air Handling
/Static
2
Fixture
Width
G
Ceiling Type:
G=Grid (lay-in T-bar)
16
Number of
Cells
Louver Finish:
L = Low
Iridescence
Semi-specular (standard)
W=White Paint
S
Ballast Cover:
S=Single V Reflector
2
Lamp
Quantity
6U
Lamp/
Fixture Length:
6" U Lamp
T8 or T12
(Nominal 24")
Voltage:
120 or 277
Options:
Add appropriate suffix to catalog
no, ie: (GLR)
Ballast Type:
1–2 Lamp Mag. T12 LE*
<20THD <10THD
1–2 Lamp Elec. T8 SO* H
I*
LOL T8 Dimming PS* *Instant Start Standard
Other dimming options. Consult factory.
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1666462 605958 585756 2625855 555250 535149 3575248 504644 484543 4534742 454138 434038 5484237 403633 393533 6453733 363229 353129 7413429 322825 312825 8383025 292522 282421 9342722 262219 252118
10 32 24 20 23 19 16 23 19 16
visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 81 75 71 80 79 69 60 71
20 30 84 78 74 73 82 73 66 65 20 40 86 80 77 75 82 75 70 69
20 60 87 81 80 78 83 75 73 72 30 20 85 79 71 76 83 75 64 70
30 30 87 82 74 70 86 78 68 65 30 40 88 83 77 72 86 79 72 68
30 60 89 84 80 75 86 79 75 72 30 80 89 85 81 78 86 79 74 72 40 20 86 82 75 75 84 77 69 71
40 30 88 83 77 70 87 80 73 67 40 40 89 85 80 73 87 81 76 70 40 60 90 86 82 75 87 81 77 73 40 80 90 86 83 78 87 81 77 73 40 100 91 86 83 78 87 81 77 73
60 30 88 84 79 73 87 81 75 70 60 40 89 86 82 75 88 82 78 73 60 60 90 87 83 77 88 82 79 75 60 80 91 87 84 79 88 83 79 75 60 100 91 87 85 80 88 83 79 75
100 40 89 86 82 77 88 82 79 74 100 60 90 87 84 79 88 82 81 77 100 80 91 87 85 81 88 83 81 78 100 100 91 88 86 82 88 83 81 78
room cavity ratio
luminaries lengthwise
luminaries crosswise
LER = FP - 49.5 IW - 58.0 BF - 0.87 Comparative yearly lighting energy cost per 1000 lumens = $4.85
ITL34139 LIGHTOLIER PLA2G16LS26U120SO
Ordering Information
Explanation of Catalog Number. Example: PLA2G16LS26U120SOGLR
Loading...