1
Dimensions
Twist-on Wirenuts
Remove Wireway Cover to expose Wirenuts for thru wiring
Wago Plug-in Wirenuts
Twist-on Wirenuts
Feed End
Feed End
Remove Wireway Cover tp expose Wirenuts for thru wiring
Wago Plug-in Wirenuts
4'
Unit
8'
Unit
Continuous End
Continuous End
2
Slide Grip Hanger Assembly End Or Middle of Row
Remove Louver by releasing four Spring-loaded Latches. Remove Wireway Cover. Remove K.O.s (2) from top of End Plate and install Slide Grip Hanger into K.O. openings. Secure Slide Grip Hanger to Fixture with Screw Provided. Feed wires through opening in End Plate, into Wireway
Tab
End Cap
Screw Provided
Wireway Cover
Ball Chain
Louver
K.O.s
Slide Grip Hanger
Screw Provided
Fixture
Screw Provided
Screw Provided
Slide Grip Hanger
Fixture
Wago Plug-ins
8
Surface Mount Direct to Surface Without Slide Grip Hanger
Insert Flexible Connector with at least 1/2" long leads into wiring compartment and secure the Flexible Connector with the Flexible Connector Locknut. Mount the Fixture to the ceiling with Mounting Screws (by others) or toggle bolts (not supplied) through four 7/32" x 9/32" rectangular holes. Make sure Fixture is mounted firmly and the ceiling can withstand the weight of the Fixture. Make electrical connections to Fixture, using twist­on wirenuts provided. Re-install Wireway Cover, install lamps (by others). Slip Ball Chain into key slots in Wireway Cover and Install Louver.
Flexible
Connector Wiring Compartment
Flexible Connector Locknut
Mounting Screw
7
Assemble Slide Grip Hanger to Fixture as in Step 2. Bring service leads from Outlet Box through AC1 and Slide Grip Hanger, securing AC1 and Slide Grip Hanger to Outlet Box.
Outlet Box, Canopy, Slide Grip Hanger
Outlet Box
© a Genlyte company 59-31135-000 Printed in U.S.A.
AC1
Slide Grip Hanger
End Plate
Fixture
K.O.'s (2)
and make wiring connections. If Fixture is to be used as an individual, or mounting is to be at joints, assemble Slide Grip Hanger to both ends of 1st Fixture. Assemble End Cap to Fixture with Screws (2) Provided at end of row. Install Wireway Cover and Louver.
Lytecel 6-page Inst. Sht.qxd 2/25/05 4:40 PM Page 1
4
Cable Set for Continuous Row or End of Row with Reflector or without Reflector
Secure cable set with threaded end of Mounting Strap through Canopy into Top Cable Bushing. Assemble Bottom Cable Bushing to Slide Grip Hanger with Nut as shown. Assemble Strain Relief in K.O. in Slide Grip Hanger and seat properly. Use Screws to assemble End Cap to Fixture. Bend tabs out to secure Slide Grip Hanger to Fixture when not installed at end of Fixture.
Catalog No. WC60 – Canopy, Cable
Catalog No. WCC60 – Canopy, Cable, Straight Cord Catalog No. WCCC60 – Canopy, Cable, Coiled Cord
Strain Relief
Tab Detail
Mounting Strap
Canopy
Top Cable Bushing
Fixture Side Rail
Bottom Cable Bushing
Slide Grip Hanger
Bottom Cable Bushing
Strain Relief Detail
Slide Grip Hanger
Fixture Side Rail
Strain Relief
Nut
Mounting Strap
Canopy
Strain Relief
Strain Relief Detail
Top Cable Bushing
Fixture Side Rail
Bottom Cable Bushing
Slide Grip Hanger
Fixture
End Cap
Nut
Strain Relief
Screw
Strain Relief
(8') 99-3/4"
(4') 48"
Slide Grip Hanger Along Length of Fixture
Slide Grip Hanger for Beginning or End of Row
3
Stem Set for End of Row or Continuous Row Mounting with Reflector or without Reflector.
Slip threaded end of stem through Canopy. Attach Stem(s) to Slide Grip Hanger using Nuts as shown. Assemble Slide Grip Hanger to Fixture Slide Rails. Assemble Ball Aligner to Stem and Slide onto Mounting Strap. For sloped ceilings, be sure opening of Mounting Strap is positioned facing upward with the slope of the ceiling or Stem will disengage. Bend Tab out to secure Slide Grip Hanger to Fixture when not installed at end of Fixture. Make wiring connections. Using Screws, secure End Cap to Fixture.
Canopy
Canopy
Stem
Stem
Nut
Nut
Slide Grip Hanger
Slide Grip Hanger
Nut
Nut
Fixture Side Rail
Fixture Side Rail
Tab Detail
Slide Grip Hanger
Nut
Stem
Mounting Strap
Ball Aligner
Ball Aligner
Mounting Strap
Nut
Slide Grip Hanger
Fixture
End Cap
(8') 99-3/4"
(4') 48"
Screw
Slide Grip Hanger Along Length of Fixture
Slide Grip Hanger for Beginning or End of Row
5
Slide Grip Hanger Mounting Locations
12" (305mm) Max. 4' Unit 24" (610mm) Max 8' Unit
12" (305mm) Max. 4' Unit 24" (610mm) Max 8' Unit
6
Join Fixtures with Screws (2) Provided. Hook wires into Slot in End Plate. Make Plug-in wiring connections in Wireway. Replace Wireway Cover.
Through Wiring/Continuous Rows
Fixture
Screw Provided
Screw Provided
Wago
Plug-ins
Supplied
#14 Gauge
Maximum Wire
Solid or Stranded
Slot
Alignment Tab
End Plate
48" (1219mm) or 96" (2439mm)
42" (1067mm) or 90" (2286mm)
3" (76mm) Min.
3" (76mm) Min.