INSTALLATION INSTRUCTIONS FOR THE LYTECEL.-.EL LUMINAIRE
FEED END / CONTINUOUS END
1
Twist-on Wirenuts
4'
Unit
Lightolier
45 INDUSTRIAL WAY, WILMINGTON, MA 01887
NOTE: Fixture should be installed by a qualified electrician
Wago Plug-in
Wirenuts
Feed End
Twist-on Wirenuts
8'
Unit
Feed End
HANGER MOUNTING LOCATIONS
2
4'
Unit
46-5/16" (1202mm)
8'
Unit
94-9/16" (2402mm) Hanger location for individual unit
95-1/4" (2419mm) Beginning or end of row and hanger location
TO REMOVE LOUVER, follow arrows 1, 2 and 3. To
3
install Louver, reverse the procedure. For
continuous row mounting, remove End Cap as
shown. Use End Cap for end of row fixture.
Continuous End
Wago Plug-in
Wirenuts
Continuous End
96-19/64" (2446mm)
Hanger location in
continuous row
FOR CONTINUOUS ROW MOUNTING, assemble
4
Fixtures using Threaded Studs (2), Washers (4),
and Nuts (4) from supply pack included. Make
plug-in wire connections.
Louver
1
3
End Cap
2
Threaded
Nut
Washer
Fixture
© Lightolier 2007 59-31160-000 Printed in U.S.A.
Stud
End Cap
Tab (2)
Fixture
End
Cap
Nut (4)
Washer (4)
Threaded
Stud (2)
Wago Plug-in
Supplied
#14 Gauge
Maximum Wire
Solid or
Stranded
ASSEMBLE HANGER SET FOR BEGINNING OR
5
CONTINUOUS ROW as shown. To acquire the suspension length, press down on the Spring-
loaded Glider and
release when
Canopy
proper length is
set. See Detail "A".
Press
Here
Stainless
Steel
Cable
TO LEVEL FIXTURE, loosen Knurled Screw,
6
adjust to required position, tighten Knurled
Screw to secure.
Spring-loaded
Glider
Knurled
Screw
Cable
Detail A
Cut-off
Excess
Cable
Fixture
HANGER ASSEMBLY FOR CONTINUOUS ROW
7
Cable
Springloaded
Glider
Step 1
With Fixture suspended
by the Cable at the
opposite end, attach one
end of the Cable with
Toggle into Fixture A.
Toggle
for
Fixture B
Fixture
Step 2
Install the next Fixture
and attach the Cable End
into Fixture B.
A
Cable
A
Step 3
Attach both the washers
and nuts to the two
Threaded Studs.
Threaded
Studs (2)
B
Threaded
Studs (2)
Washer
Nut