Lightolier Lytecaster 2001, Lytecaster 2001CL, Lytecaster 2001CD, Lytecaster 2001WH Specification

Lytecaster
3 5/8"
4 1/2"
7 1/4"
®
Performance Recessed CFL Downlighting 2001
Page 1 of 2 3 ¾" Aperture Vertical Open, Compact Fluorescent, Performance Series, Reflector Trim
Complete Fixture consist s of Frame-In Kit and Reflector Trim. Select each separately.
Uniframe™ Compact Fluorescent Performance Series Reflector Trims
Catalog No. Description Catalog No. Installation Type Lamping
2001CL 2001CD 2001WH
3 3/4” Vertical Open Downlight – Specular Clear 3 3/4” Vertical Open Downlight – Clear Diffuse 3 3/4” Vertical Open Downlight – Matte White
Features
1. Reflector: Formed aluminum. Matte White flange.
2. Finishes: CL = Specular Clear (Iridescent Free coating) CD = Clear Diffuse
WH = Matte White Paint
4. Performance Data: 65˚ Cutof f angle. See at tached photometric repor ts for distribution and efficiency data. Go to w ww.lightolier.com for .IES files.
Compatible Frame-In Kits
(See Individual Frame-In Kit Specification Sheets)
2001F13U
2001F18U
2001F13ICU/N
2001F18ICU/N
Uniframe™ Non-IC 120/277v 13w Quad/ Triple
Uniframe™ Non-IC 120v/277v 18w Triple
Performance IC 120v/277v 13w Quad/ Triple
Performance IC 120v/277v 18w Triple
Labels
cULus Listed. Suitable for Damp Locations. I.B.E.W.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s): Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC • C1007
Lytecaster
1
1
1
®
Performance Recessed CFL Downlighting 2001
Page 2 of 2 3 ¾" Aperture Vertical Open, Compact Fluorescent, Performance Series, Reflector Trim
18W TRIPLE TUBE L AMP, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
CANDLEPOWER SUMMARY
75
150
225
300
SC = 1.5
CERTI FIED TEST RE PORT NO. 30 38FR COMPU TED BY LSI PR OGRAM **TEST- LITE**
60˚
30˚
Angle 0˚ CP
0
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
239 246 260 266 271 267 255 238 215 180 130
59 19
1 0 0 0 0
0
13W TRIPLE TUBE LAMP, LUMEN RATING = 900 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
CANDLEPOWER SUMMARY
56
113
169
225
SC = 1.5
CERTI FIED TEST RE PORT NO. 30 40FR COMPU TED BY LSI PR OGRAM **TEST- LITE**
60˚
30˚
Angle 0˚ CP
0
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
190 195 207 212 213 209 202 191 175 151 108
53 18
3 1 0 0 0 0
ZONA L LUMEN SUMM ARY
Zone Lumens
0-10 23.9 4 10-20 75 .59 20-3 0 122.65 30- 40 148.0 9 40- 50 136.2 8 50- 60 58.12 60-70 4.48 70-8 0 .0 80- 90 0
90-10 0 0 100-110 0 110-120 0 120-130 0 130-140 0 140-150 0 150-160 0 160-170 0 170-180 0
ZONA L LUMEN SUMM ARY
Zone Lumens
0-10 19.0 2 10-20 6 0.03 20-3 0 9 6.41 30- 40 119.11 40- 50 113.45 50- 60 5 0.56 60-70 5 .48 70-8 0 .13 80- 90 0
90-10 0 0 100-110 0 110-120 0 120-130 0 130-140 0 140-150 0 150-160 0 160-170 0 170-180 0
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt 0-30 22 2.19 18 .5 39 0-40 370. 28 3 0.9 65.1 0-60 564. 67 47.1 9 9.2 0-90 56 9.15 47.4 100
90-120 0 0 0 90-130 0 0 0 90-150 0 0 0 90-180 0 0 0
0-180 569.15 47.4 10 0
Efficiency = 47.4%**
**
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
0-30 175.46 19.5 37.8 0-40 294.57 32.7 63.5 0-60 458.58 51 9 8.8
0-90 464.18 51.6 10 0 90-120 0 0 0 90-130 0 0 0 90-150 0 0 0 90-180 0 0 0
0-180 464.18 51.6 10 0
Efficiency = 51.6%**
**
Ceiling 80% 70% 50% 30% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
Determined In Accordance With Current IES Published Procedures
COEFFICIENTS OF UTILIZATION
0 56 56 56 56 55 55 53 53 50 50 47 1 53 52 50 49 50 48 4 9 47 47 45 43 2 50 47 44 42 46 42 44 41 43 40 38 3 46 42 39 37 42 37 40 36 39 35 34 4 43 38 35 32 38 32 37 32 36 31 30 5 40 35 31 29 3 4 28 33 28 32 28 27 6 37 32 28 25 31 25 30 25 30 25 24 7 35 29 25 23 29 23 28 23 27 22 21 8 32 27 23 21 26 21 26 20 25 20 19 9 30 24 21 19 24 19 24 18 23 18 18
10 28 23 19 17 22 17 22 17 22 17 16
Luminai re Input Wa tts = 22.0
COEFFICIENTS OF UTILIZATION
61 61 61 61 60 60 57 57 55 55 52
0
58 5 6 54 53 55 52 53 50 51 49 47
1
54 51 48 46 50 45 48 44 46 43 41
2
50 4 6 42 40 45 39 44 39 42 38 37
3
46 41 38 35 41 35 40 34 38 34 32
4
43 3 8 34 31 37 31 36 30 35 30 29
5
40 3 4 30 27 34 27 33 27 32 27 26
6
37 31 27 24 31 24 30 24 29 24 23
7
35 2 9 25 22 28 22 28 22 27 22 21
8
33 26 22 20 26 20 25 20 25 20 19
9
31 24 21 18 24 18 24 18 23 18 17
10
Luminai re Input Wa tts = 17.0
13W QUAD TUBE LAMP, LUMEN RATING = 900 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
CANDLEPOWER SUMMARY
50
100
150
200
SC = 1.4
CERTI FIED TEST RE PORT NO. 30 39FR COMPU TED BY LSI PR OGRAM **TEST- LITE**
Angle 0˚ CP
60˚
30˚
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85
0
174 179 183 182 187 187 179 164 146 126
ZONA L LUMEN SUMM ARY
Zone Lumens
0-10 17.21 10-20 52 .09 20-3 0 85 .75 30- 40 102.2 2 40- 50 9 5.83 50- 60 45 .94 60-70 4.74 70-8 0 0 80- 90 0
97 48 17
2
0 0 0 0
90-10 0 0 100-110 0 110-120 0 120-130 0 130-140 0 140-150 0 150-160 0 160-170 0 170-180 0
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
0-30 55.0 5 17.2 38.4 0-40 257.28 28 .6 63 .7 0-60 3 99.05 44.3 98. 8
0-90 403.78 4 4.9 100 90-120 0 0 0 90-130 0 0 0 90-150 0 0 0 90-180 0 0 0
0-180 403.78 4 4.9 100
Efficiency = 44.9%**
**
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
10 2 7 21 18 16 21 16 21 16 20 16 15
Determined In Accordance With Current IES Published Procedures
COEFFICIENTS OF UTILIZATION
0 5 3 53 53 53 52 52 50 50 48 48 45 1 5 0 49 47 46 48 45 46 4 4 44 43 41 2 47 44 42 40 4 3 39 42 38 40 38 36 3 4 4 40 37 35 39 34 38 34 37 33 32 4 4 0 36 33 30 35 30 34 30 33 29 28 5 3 7 33 29 27 32 27 31 26 30 26 25 6 3 5 30 26 24 29 24 29 24 28 23 22 7 3 2 27 24 21 27 21 26 21 26 21 20 8 3 0 25 22 19 25 19 24 19 24 19 18 9 2 8 23 20 17 23 17 22 17 22 17 16
Luminai re Input Wa tts = 16.0
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 Genlyte Group LLC • C1007
Loading...