Lightolier Lytecaster 1071 Specification

Lytecaster
®
Recessed Downlighting 1071
Page 1 of 2 5" Aperture Basic White Reflector Reflector Trim
6 3/4"
1071/1002P1 Series
Standard Incandescent
Complete Fixture consists of Reflector Trim & Frame-In Kit. Select each separately.
5 1/16"
6 1/8"
6 3/4"
7 1/2"
Reflector Trim Frame-In Kit — See Individual Frame-In Kit Specification Sheets
LED
1071
Perma White
Frame-In Kit Installation Type Lamping Height
1001LED 1000LEDREM L56LED
Frame-In Kit Ceiling Type Lamping Height
1000P1 1002P1
1000P1 1002P1
1003R
1000IC 1000AICM
1004ICX/N
1004IC/N 1004ICR 1004SIC/N 1004SICR
1004IC/N 1004ICR
1004SIC/N 1004SICR
Non-IC Non-IC Remodeler Non-IC Retrofit
Incandescent
Non-IC 75W A19,
Non-IC 75W A19,
Non-IC Remodeler 75W A19,
IC AirSeal® IC
AirSeal® IC 52W A19
AirSeal® IC IC Remodeler AirSeal® IC
IC Remodeler
Non-IC
Non-IC Remodeler
Non-IC
Non-IC Remodeler
LED LED LED
PAR30* 65W BR30
PAR30* 65W BR30
PAR30* 85W BR30
40W A19 65W BR30, 75W PAR 30
65W BR30 75W PAR 30
50W PAR30 65W BR30
52W A19 75W PAR30 85W BR30
75W PAR30 85W BR30
6 3/4"" 6 3/4" 6 3/4"
6 3/4"
6 3/4"
6 3/4"
7 5/16" 7 5/16
7 1/4"
7 1/2" 7 1/2" 5 1/2" 5 1/2"
7 1/2" 7 1/2"
5 1/2" 5 1/2"
Frame-In Kit Ceiling Type Lamping Height
1001F13U Series
1001F18U Series
1004F13 Series
1004F18** Series
1004F26** Series
1001F13ICU/N
1001F18ICU/N
1910XFH1
**Lightolier recommends the use of triple tube lamps *(Use Socket Extender Accessory With Short Neck)
UniFrame™ Non-IC
UniFrame™ Non-IC
IC (1) Quad/Triple 13W (GX24q-1) 7 1/2"
IC (1) Quad/Triple 18W (GX24q-2) 7 1/2"
IC (1) Quad/Triple 26W (GX24q-2) 7 1/2"
Performance IC(1) Triple 13W (GX24q-1) 7 1/4"
Performance IC(1) Triple 18W (GX24q-2) 7 1/4"
Conversion Kit
1071/1003R
0
Non-IC
Remodeler Ring
1071/1004IC/N
0
Convertible
IC/Non-IC
Fluorescent
(1) Triple 13W (GX24q-1) 5 7/8"
(1) Triple 18W (GX24q-2) 5 7/8"
(1) Quad 13W (GX23-2) 6 3/4"
Features
1. Reflector: Hydroformed aluminum, .040" thick, (18 ga.); non-yellowing,
scratch resistant Perma White Finish, 88% reflectance; white trim flange.
2. Frame-In Kit: (1002P1 standard frame shown). Other frames listed above and shown on the right. See Frame-In Kit specification sheets for more details.
Options & Accessories
Medium-Base PAR30 1968 - For use w/short neck PAR30 lamps Socket Extender: Spread Lens: L56WWLENS - Proprietary spread lens for use with combination
of wall washer optics and LED Frame-In Kits.
Labels
UL (Suitable for Damp Locations); I.B.E.W.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s): Notes:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2011 Genlyte Group LLC • K1111
Lytecaster
®
Recessed Downlighting 1071
Page 2 of 2 5" Aperture Basic White Reflector Reflector Trim
Use quick calculator chart to determine the spacing of 100 Watt BR30 FL units for a desired level of illumination. Conversion Factor: 75W A19, F.C. x 0.85. 1 Lt 13W Quad Tube, F.C. x 0.6.
Spacing Ratio = 0.9
CERTIFIED TEST REPORT NO. 0275FR
COMPUTED BY LSI PROGRAM **TEST LITE**
RECESSED OPEN LYTECASTER DOWNLIGHT
5 1/16" DIA. APERTURE, BASIC WHITE REFLECTOR
ONE 75W BR30 FLOOD LAMP. LUMEN RATING = 770LMS
CANDLEPOWER SUMMARY
ANGLE MEAN CP LUMENS
0 447 5 438 42 10 420 15 386 108 20 339 25 293 136 30 254 35 225 142 40 200 45 164 122 50 104 55 69 67 60 56 65 45 44 70 33 75 21 23 80 11 85 5 6 90 1
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMPS % LUMINAIRE
0 –30 286 37.20 41.49 0–40 428 55.63 62.04
DATE: APRIL 3,1997 PREPARED FOR: LIGHTOLIER, FALL RIVER, MA
0–60 617 80.15 89.40 0–90 690 89.66 100.00 40–90 262 34.03 3796.00 60–90 73 9.51 10.60 90–180 0 .00 .00 0–180 690 89.66 100.00
**EFFICIENCY = 89.7% **
Coefficients of Utilization
80 70 50 30 10
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 1 .97 .94 .92 .95 .93. .90 .91 .89 .88 .88 .89 .85 .85 .84 .82 .81 2 .88 .84 .80 .87 .83 .79 .84 .80 .77 .81 .78 .76 .79 .76 .74 .73 3 .80 .75 .71 .79 .74 .70 .77 .72 .69 .74 .71 .68 .72 .69 .67 .65 4 .74 .68 .63 .73 .67 .63 .71 .66 .62 .69 .65 .61 .67 .63 .61 .59 5 .68 .61 .56 .67 .61 .56 .65 .60 .56 .63 .59 .55 .62 .58 .55 .53 6 .62 .56 .61 .61 .55 .51 .60 .54 .50 .58 .54 .50 .57 53 .50 .48 7 .57 .50 .46 .56 .50 .46 .55 .49 .45 .54 .49 .45 .53 .48 45 .43 8 .52 .46 .42 .52 .46 .41 .51 .45 .41 .50 .45 .41 .49 .44 .41 .39
ROOM CAVITY RATIO
9 .48 .41 .37 .48 .42 .37 .47 .41 .37 .46 .41 .37 .34 .40 .37 .35 10 .45 .38 .40 .44 .38 .34 .43 .38 .34 .43 .37 .34 .42 .37 .34 .32
Conversion Factor: 75W A19, C.U. x 0.5. 1 Lt. 13W Quad Tube, C.U. x 0.5.
To convert lighting data for a lower wattage incandescent lamp of the same type, multiply the footcandle (or candlepower) values by the ratio of the lumens of the two lamps. The coefficients of utilization remain the same.
20% FLOOR CAVITY REFLECTANCE
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2011 Genlyte Group LLC • K1111