Lightolier LSW Specification

Page 1
LSW Series
100
Ceiling/Wall Fluorescent, T5 or T8
Page 1 of 3
T5 Lamps T8 Lamps
3-7/8" (98mm)
4-1/4" (108mm)
6-1/8"
(156mm)
24-1/4" (616mm)
6-3/32" (155mm)
48-1/2" (1232mm)
3-7/8" (98mm)
6-3/32" (155mm)
6-1/4"
(159mm)
Ordering Information
LS
Surface/Wall
Fluorescent
Fixture Length
2 = 24" 4 = 48"
(Nominal Size)
Lens Type
R
R = Linear
prismatic virgin acrylic lens
Lamp
Qt y.
1 = 1 Lamp 2 = 2 Lamps
Features
• For ceiling or wall mounted applications.
• Can be vertically or horizontally mounted on wall.
• Only 3 7/8" deep, meets Americans with Disabilities Act for wall
mounted fixtures.
• Low brightness .125 thick linear prismatic virgin
acrylic refractor.
• Invisible spring steel latches align refractor to housing.
• 20 gauge cold rolled steel post painted baked white enamel
end caps.
• Nominal 2' and 4' lengths.
• 73.9% efficient (T8 lamps).
4-1/4" (108mm)
24-1/2" (622mm)
Lamps
(by others)
14 = T5 2' Leng th 17 = T8 2' Leng th 28 = T5 4' Le ngt h 32 = T8 4' L eng th 54 = T5H O 4'
Job Information Type:
Job Name:
Cat. No.:
Notes:
Length
Ballast
Voltage
120 = 120v 277 = 27 7v
UNV = 120 -277v
1 or 2 Lam p Elec . T8 HI* 1 or 2 Lam p Elec . T8 P2‡ 1 or 2 Lam p Elec . T5 PG‡ LOL Dimming T5 PF LOL Dimming T8 PS
*Instant Start Standard ‡Pro gra m Rapi d Star t (UNV only) NOTE: Fo r T8 UNV, you must u se HI Ballast Code.
Type
<20THD <10THD
Options
Add
appropriate
suff ix to catalog
no., i.e.: (C)
Page 2
LSW Series
Ceiling/Wall Fluorescent, T5 or T8
Page 2 of 3
Specifications
Materials: Chassis Parts–Die-formed code gauge cold rolled
steel. End Caps–20 gauge cold rolled steel.
Finish: Chassis exterior–Post painted white baked acrylic
enamel. End Caps–Post painted baked white enamel. Rust
preventative undercoating.
Refractor: Low brightness .125 linear prismatic, extruded virgin
acrylic lens.
Electrical: Thermally protected class “P” ballast C.B.M.
approved, non PCB. If K.O. is within 3" of ballast, use wire
suitable for at least 90°.
Labels: I.B.E.W., UL and ULc listed. UL listed for damp locations
This product may have a mercury containing lamp. Manage in
accord with Disposal Laws. See: www.lamprecycle.org
Options & Accessories
Fusing: Internal fast blow fusing: Suffix: A.
Internal slow blow fusing: Suffix: C.
Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One
per fixture standard. Suffix: R. One per ballast. Suffix: B.
Emergency Power Pack: Factory installed emergency power
pack includes charger and inverter concealed in fixture channel.
Upon loss of AC power, operates one lamp at reduced light.
T8 Suffix: E1. (consult factory for T5 option)
Stem and Canopy Sets: Suspends fixture 6", 12", 18" or 24"
from surface. Catalog Number: ASC6 CSP (6")
ASC12 C SP (12")
ASC18 CSP (18")
ASC24 CSP (24")
Job Information Type:
Page 3
Photometry
Model No. LS4R232UNVHI
LER = 66.9 IW = 55.4 BF = 0.88
Compa rative yearly lighting ener gy cos t per
Report Number: G2010291
Catalog Number: LS4R232UNVHI
Lamps: (2) F032T8
Luminaire: LSW Series 4' luminaire
Ballast: RIC2S40TP
Repor t is based on 2850 lumens per lamp.
Efciency: 73.9%
CIE Type: Direct/Indirect
Plane: 0-Deg. 90-Deg.
Spacing Criteria: 1.1 1. 2
Shielding Angles: 90 90
Plane: 0-Deg. 90-Deg.
Luminous Length: 6.000 48.000
1000 lumens = $3.59
LSW Series
Ceiling/Wall Fluorescent, T5 or T8
Page 3 of 3
Candela Distribution
Vertical
Angle
15 1116 1155 118 4 326 25 1028 1093 1134 502 35 899 973 993 598 45 724 696 665 542 55 483 485 526 443 65 235 367 508 37 7 75 110 309 468 319 85 20 229 404 243 90 6 202 364 95 6 203 351 20 8
105 5 185 300 180
115 5 155 253 143 125 5 12 4 201 103 135 5 88 142 63 145 6 58 94 34 155 6 34 56 15 165 6 14 24 4 175 5 2 3 180 2 2 2
Horizontal
0 45 90 0 1176 117 6 1176 5 1162 117 5 1188 112
Angle
Zonal Lumens
Coefficients of Utilization
Ceiling 80% 50% 30% Wall 70 50 30 50 30 10 50 30 10 RC
RW
1 76 72 69 64 61 59 58 56 55 2 69 63 57 55 51 48 51 48 45 3 63 55 49 49 44 40 45 41 38 4 58 49 42 43 38 34 40 36 32 5 53 44 37 39 34 30 36 32 28 6 49 39 33 35 30 26 33 28 25 7 45 36 29 32 27 23 30 25 22 8 42 33 26 29 24 21 27 23 20
Room Cavity Ratio
9 40 30 24 27 22 19 25 21 18
10 37 28 22 25 20 17 24 19 16
Zonal Cavity Method
Effective Floor Reflectance = 20%
Average Luminance data in candela / sq. meter
Angle 45˚ 90˚
45 3992. 4363. 4830. 55 2 937. 3485. 4620. 65 16 48 . 3204. 5869. 75 946. 3573. 8263. 85 2 31. 4105. 16163.
Zonal Lumen Summary
Zone Lumens % L amp % Fixt .
0- 30 940 16. 5 22.3 0- 40 1538 27.0 36. 5 0- 60 2523 44.3 59.9
0- 90 3463 60.8 82.2 90 -120 531 9.3 12. 6 90 -130 634 11.1 15 .1 90 -150 732 12.8 17.4 90 -180 7 51 13. 2 17. 8
0-18 0 4214 73 .9 100 .0
Model No. LS2R217UNVHI
LER = 66.9 IW = 29.8 BF = 0.93
Compa rative yearly lighting ener gy cos t per
Report Number: G2010296
Catalog Number: LS2R217UNVHI
Lamps: (2) F17 T 8
Luminaire: LSW Series 2' luminaire
Ballast: ICN-2P32-SC
Repor t is based on 1400 lumens pe r lamp.
Efciency: 76.6%
CIE Type: Direct/Indirect
Plane: 0-Deg. 90-Deg.
Spacing Criteria: 1.1 1. 2
Shielding Angles: 90 90
Plane: 0-Deg. 90-Deg.
Luminous Length: 6.000 48.000
1000 lumens = $3.59
Candela Distribution
Vertical
Angle
15 526 541 554 153 25 482 509 529 234 35 418 454 481 283 45 337 381 417 293 55 234 30 0 3 41 264 65 14 0 217 268 2 12 75 66 154 216 158 85 13 99 164 10 5 90 3 79 151
95 3 82 158 91 105 2 94 15 0 90 115 2 83 13 1 76 125 3 72 112 59 135 3 53 85 38 145 3 36 57 21 155 5 23 36 10 165 9 17 23 5 175 9 10 11 180 8 8 8
Horizontal
0 45 90 0 553 553 553 5 549 553 557 53
Angle
Zonal Lumens
Coefficients of Utilization
Ceiling 80% 50% 30% Wall 70 50 30 50 30 10 50 30 10 RC
RW
1 88 88 88 77 77 77 71 71 71 2 79 75 71 66 63 61 61 59 57 3 72 65 59 57 53 50 53 49 46 4 65 57 50 50 45 41 46 42 39 5 59 50 43 44 39 35 41 37 33 6 55 45 38 40 34 30 37 32 29 7 50 40 33 36 30 26 33 29 25 8 47 36 30 33 27 23 30 26 22
Room Cavity Ratio
9 43 33 27 30 24 21 28 23 20
10 40 30 24 27 22 19 26 21 18
Zonal Cavity Method
Effective Floor Reflectance = 20%
Average Luminance data in candela / sq. meter
Angle 45˚ 90˚
45 4845. 478 5. 4649. 55 3982. 42 59. 4153.
1
65 3 031. 3671. 37 21. 75 2048. 3349. 3615 . 85 7 53. 3 147. 3592 .
Zonal Lumen Summary
Zone Lumens % L amp % Fixt .
0- 30 439 15. 7 20.5 0- 40 722 25.8 33.7 0- 60 1279 45.7 59.6
0- 90 1755 62.7 81.8 90 -120 257 9.2 12 .0 90 -130 3 16 11. 3 14.7 90 -150 375 13.4 17.5 90 -180 391 13. 9 18. 2
0-18 0 2 145 76 .6 100.0
Philips Lightolier e: lol.webmaster@philips.com t: (508) 679-8131, Technical info. (978) 657-7600 w: www.lightolier.com
LSW Series July 28, 2011
Specifications are subject to change without notice. © Koninklijke Philips Electronics N.V., 2011. All rights reserved.
Job Information Type: