Lightolier LIS9G12PR132 User Manual

Lytecel Recessed Fluorescent LIS9G12PR132
Page 1 of 2 9" x 48", 12 Cell (1 Row) Parabolic Louver, Static or Air Supply/Return, 1 Lamp T8
IES RP1 For VDT Areas
Features
• Meets IES RP1 for lighting VDT areas.
• 65.2% efficient (T8).
• 1.5 spacing mounting ratio.
• Vertical grain on louver eliminates reflected lamp image on cross baffle.
• Louver frame with positive light stop.
• Spring loaded latches (self centering).
• Reversible louver hinging.
• Louver has protective dust guard.
• Only 6-1/8" deep body.
• Black housing exterior for cooler ballast operating temperature.
• Turned-in edges for safe handling.
• UL-Listed twin knockout access plate.
• Air closure strips (optional).
• Construction to meet NYC Code or Chicago Plenum is available.
• Optional DALI ballast accepts digital dimming commands from computers, scene controllers and automatic control devices.
Mounting Methods Dimensions
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. Copyright 2003 Lightolier Section 2/Folio G07-10
G
exposed T-grid ceiling.
9"
9/16" to 1"
T
exposed slot T-grid ceiling.
9"
1-1/2" max.
9/16"
1-1/2" max.
9"
(229mm)
6-1/8"
(156mm)
2" x 2-1/2" Access Plate with (2) 7/8" K.O.s
2-5/32"
(55mm)
48"
(1219mm)
5"
(127mm)
39-1/4"
(997mm)
Air Supply Slots (LIA only)
4 hold-down clips
supplied with fixture
5/03
Lytecel Recessed Fluorescent LIS9G12PR132
Page 2 of 2 9" x 48", 12 Cell (1 Row) Parabolic Louver, Static or Air Supply/Return, 1 Lamp T8
IES RP1 For VDT Areas
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. Copyright 2003 Lightolier Section2/Folio G07-10
Job Information Type:
Ordering Information
Explanation of Catalog Number. Example: LIS9G12PR132120SOGLR
Options/Accessories
Access Plate: Top Wiring access plate is shipped with fixture
as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog Number: ACP5 CSP.
Electrical/Wiring Options: Consult factory. Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF. Air Closure Strips: Suffix: ACS4 (factory installed). Drywall Kit: Order Catalog Number: FK99X4. Chicago Plenum: Suffix: CP.
Specifications
Performance: In an installation of 1 lamp 32W luminaires in a room cavity
ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .70 with a spacing to mounting ratio of 1.9 perpendicular to the lamps. To meet IES RP-1 for VDT areas the VCP (visual comfort probability) shall not be less than 96 either crosswise or lengthwise and the candela value between 55° and 90° in the 0° to 90° planes shall not exceed 195. Candelas at Nadir (0°) not to exceed 525. Air handling: (LIA only) side air passages for air supply or air return. Optional side closure strips.
Specifications (continued)
Materials: Chassis parts are die-formed cold rolled steel.
Housing is with all
edges turned-in for safe handling.
Louver: Pre-anodized aluminum (Coilzak@or equal). Finish: Louver—specular low iridescence pre-anodized reflector sheet. Reflector: Semi-Specular reflector sheet, 95% reflective. Chassis exterior—
black baked polyester enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
Photometry
Model No. LIS9G12PR132120SO
G02090 LIS9G12PR132120SO
coefficients of utilization — zonal cavity method
RF 20 20 20 RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1737169 676665 656463 2696562 625957 605856 3645956 575451 555350 4605450 524946 514845 5565045 484441 474341 6534641 444037 434037 7494237 413734 403634 8463934 383431 373331 9433631 353128 343128
10 41 33 29 32 29 26 32 28 26
visual comfort probability
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 92 95 93 82 99 98 97 92
20 30 93 95 93 83 99 98 97 94 20 40 93 95 93 83 99 98 98 94 20 60 95 96 93 83 99 98 98 94
30 20 93 95 94 85 99 98 97 93 30 30 93 95 93 86 99 98 98 94 30 40 93 95 93 86 99 98 98 94 30 60 96 96 94 886 99 98 98 94 30 80 96 97 94 86 99 98 98 94
40 20 93 95 94 86 99 98 98 93 40 30 93 95 93 86 99 98 98 94 40 40 93 95 94 86 99 98 98 94 40 60 96 96 94 86 99 98 98 94 40 80 97 97 94 86 99 98 98 94 40 100 97 97 94 86 98 98 98 94
60 30 93 95 94 86 99 98 98 94 60 40 93 95 94 86 99 98 98 94 60 60 95 96 94 86 99 98 98 94 60 80 97 97 94 87 99 98 98 94 60 100 96 97 95 87 98 98 98 94
100 40 93 95 94 86 99 98 98 94 100 60 97 96 94 87 99 98 98 94 100 80 97 97 93 87 98 98 98 94 100 100 96 97 93 87 98 98 98 95
room cavity ratio
luminaries lengthwise
luminaries crosswise
LI
LI:
Anodized
Aluminum
Louver
for VDT use
Blank = Standard
N = NYC Code
Body Style:
A=Air Handling S=Static
9
Fixture
Width
Ceiling Type:
G= Grid (lay-in T bar) T=Slot grid or
two-directional concealed T (see options)
12
Number of
Cells:
1 row of
12 cells
Louver Finish:
P=Low
Iridescence Specular
L=Low
Iridescence Semi-
specular
R
Reflector:
R= Semi-Specular
95% Reflective
1
Lamp
Quantity
32
Lamp Fixture
Length:
32=T8
(Nominal 48")
Voltage:
120 or 277
Ballast type:
<20THD <10THD
1 Lamp Elec. T8 SO* H
I*
*Instant Start Standard Other dimming options, consult factory.
DA=DALI digital addressable dimming.
Options:
Add appropriate suffix to catalog
no, ie: (GLR)
LER = FP - 53.2 IW - 32 BF - 0.92 Comparative yearly lighting energy cost per 1000 lumens = $4.51
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.