Lightolier LIS6G20LW228 User Manual

Lytecel Recessed Fluorescent LIS6G20LW228
Page 1 of 2 6" wide x 48", 20 Cell (1 Row) Parabolic Louver,
Air Return/Static, 2 Lamp T5, IES RP1 For VDT Areas
Features
• 52.0% efficient (2 lamp) semi-specular louver.
• 55.3% efficient (2 lamp) specular louver.
• 1.3 spacing mounting ratio semi-specular louver
• 1.5 spacing mounting ratio specular louver.
• Semi-specular or specular, low iridescence, pre-anodized aluminum louver.
• Vertical grain on cross blades eliminates reflected lamp image.
• Louver has protective dust guard.
• Only 5-1/2" deep body.
• Black housing exterior for cooler ballast operating temperature.
• UL-Listed twin knockout access plate.
• Can be mounted in continuous rows.
• 2 hold-down clips standard.
• Compatible with Armstrong TECHZONE
• Meets NYC Code requirements.
• Construction to meet Chicago Plenum Code is available.
• Optional DALI ballast accepts digital dimming commands from computers, scene controllers and automatic control devices.
Mounting Methods Dimensions
exposed T-grid ceiling.
G
®
exposed slot T-grid ceiling.
T
ceiling systems.
6"
hold-down clips (1 at each end)
2" max.
15/16"
or
9/16"
6"
A/D
6"
Tegular grid ceiling
2" max.
9/16"
2" max.
15/16"
or
9/16"
5-1/2"
(139mm)
4-1/4" (108mm)
6" (162mm)
2" x 2-1/2" Access Plate with (2) 7/8" K.O.s
7-3/8"
(187mm)
1-3/4" (44mm)
39-1/4" (997mm)
48"
(1220mm)
Job Information Type:
Job Name:
Cat. No.:
48"
(1200mm)
Joint of Two Units
Air Return Slots (LIA only)
48"
(1200mm)
Shown in Armstrong TECH ceiling.
3/07
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company
Section 2/Folio G07-34
Lytecel Recessed Fluorescent LIS6G20LW228
Page 2 of 2 6" wide x 48", 20 Cell (1 Row) Parabolic Louver,
Air Return/Static, 2 Lamp T5, IES RP1 For VDT Areas
Model No. LIS6G20LW228120PG
LER = FP - 43.3 IW - 66.0 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $5.54
Report Number: G1206007 Catalog Number: LIS6G20LW228120PG Lamp: F28 T5 Luminaire: 6" wide Troffer with semi­specular louver and white reflector. Ballast: Advance ICN-2S28 Report is based on 2750 Lumens per lamp. Efficiency: 52.0%
CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.943 5.816
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
1 58 56 55 53 52 51 51 50 49 2 54 51 48 48 46 45 47 45 44 3 50 46 43 44 41 39 43 41 39 4 47 42 38 40 37 35 39 36 34 5 44 38 34 37 33 31 36 33 31 6 41 35 31 33 30 28 33 30 27 7 38 32 28 31 27 25 30 27 25 8 35 29 25 28 25 23 28 25 22 9 33 27 23 26 23 20 26 23 20
10 31 25 21 24 21 19 24 21 19
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 6515. 6821. 6766. 55 4728. 3371. 1327. 65 342. 473. 408. 75 64. 107. 193. 85 64. 128. 191.
0
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 1373 1373 1373
5 1300 1383 1363 133
15 1278 1420 1516 393
25 1188 1382 1403 614
35 1023 1139 1216 711
45 829 868 861 668
55 488 348 137 288
65 26 36 31 37
75 3596
85 1232
90 121
TYPICAL V.C.P.'s
Mounting Height
Room Luminaires Luminaires
Size 0 Deg Plane 90 Deg Plane
30x30 87 84 80 71 93 89 85 76 40x40 87 84 81 78 94 91 89 80 60x30 87 84 81 77 93 89 87 78 60x60 87 83 81 79 94 91 90 83
100x100 88 83 81 79 94 92 91 86
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 1144 20.8 40.0 00-040 1856 33.7 64.9 00-060 2812 51.1 98.4 00-090 2858 52.0 100.0
90-180 0000 0.0 000.0
00-180 2858 52.0 100.0
Lengthwise Crosswise
8.5 10 8.5 10 8.5 10 8.5 10
Model No. LIS6G20PW228120PG
LER = FP - 45.8 IW - 66.0 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $5.24 Report Number: G1206008 Catalog Number: LIS6G20PW228120PG Lamps: F28 T5 Luminaire: 6" wide Troffer with semi­specular louver and specular reflector. Ballast: Advance ICN-2S28 Report is based on 2750 Lumens per lamp.
Efficiency: 55.3% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.5 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.943 5.816
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1 62 60 58 56 55 54 54 53 52 2 58 54 51 51 49 47 50 48 46 3 54 49 46 47 44 42 45 43 41 4 50 45 41 43 39 37 41 39 36 5 46 40 36 39 35 33 38 35 32 6 43 37 33 35 32 29 35 31 29 7 40 34 30 33 29 26 32 29 26 8 38 31 27 30 26 24 29 26 24 9 35 29 24 28 24 22 27 24 21
10 33 26 22 26 22 20 25 22 20
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 7018. 7568. 7701. 55 5677. 3652. 1095. 65 13. 460. 381. 75 21. 86. 193. 85 64. 128. 255.
0
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 1348 1347 1348
5 1337 1348 1377 134
15 1278 1470 1522 414
25 1184 1483 1448 649
35 1079 1221 1262 756
45 893 963 980 737
55 586 377 113 314
65 1 35 29 27
75 1495
85 1242
90 011
TYPICAL V.C.P.'s
Mounting Height
Room Luminaires Luminaires
Size 0 Deg Plane 90 Deg Plane
30x30 86 76 73 71 93 88 85 70 40x40 86 76 75 74 94 90 87 79 60x30 86 76 75 76 93 88 85 77 60x60 86 77 76 76 94 91 89 82
100x100 86 77 76 76 93 92 91 85
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 1198 21.8 39.4 00-040 1954 35.5 64.3 00-060 3004 54.6 98.8 00-090 3039 55.3 100.0
90-180 0000 0.0 000.0
00-180 3039 55.3 100.0
Lengthwise Crosswise
8.5 10 8.5 10 8.5 10 8.5 10
Ordering Information
Explanation of Catalog Number. Example: LIS6G20LW228120PG
20
Number of
Cells:
1 row of
20 cells
Louver Finish:
L=Low
Iridescence Semi-
P=Low
Iridescence S
pecular
LI:
Lytecel 6"
Standard Lytecel
LI
For NYC Code – Local 3 Manufactured
LN
Body Style:
A =Air Return S =Static
6
Fixture
Width
Ceiling Type:
G = 9/16" or
15/16"Grid
T = Slot Grid A = 9/16" Tegular
Grid
D = 15/16" Tegular
Grid
Options/Accessories
Access Plate: Top Wiring access plate is shipped with fixture
access plates are required in advance for wiring convenience, specify separately. Order Catalog Number: ACP5 CSP.
Electrical/Wiring Options: Consult factory. EM Pack or Dimming Ballast: Consult factory. Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF.
Chicago Plenum: Suffix: CP.
as standard. When
Specifications
Performance: In an installation of 2 lamp 28W semi-specular luminaires in a
room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .56 with a spacing to mounting ratio of 1.3 perpendicular to the lamps. To meet IES RP-1 for VDT areas the VCP (visual comfort probability) shall not be less than 87 either crosswise or lengthwise and the candela value between 55° and 90° in the 0° to 90° planes shall not exceed
2858. Candelas at Nadir (0°) not to exceed 1373.
Air Handling-(LIA) side air passages for air return. Materials: Chassis parts are die-formed cold rolled steel. Louver: Pre-anodized aluminum (Coilzak®or equal).
2
Lamp
Quantity:
(By others)
2=2 Lamp
Lamp Fixture
Length:
28=T5 54=T5HO
(Nominal 48")
Voltage:
120, 277 or
UNV=120-277
Ballast Type:
2 Lamp 28w Elec. T5 –PI† 2 Lamp 28w Elec. T5 PG†† 2 Lamp 54w Elec. T5 PG††
†Instant Start (120, 277 or UNV)
††Program Rapid Start (UNV only) DA=DALI digital addressable dimming.
Add appropriate suffix to catalog
no, ie: (GLR)
<20THD <10THD
specular
W
W
Reflector:
=White Reflector
Specifications (continued)
Finish: Louver—specular or semi-specular low iridescence pre-anodized reflector sheet. Reflector: White baked polyester enamel or specular reflector. Chassis exterior—black baked polyester enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company
Section 2/Folio G07-34
Options:
Loading...