LG Series
ARCHITECTURAL LED EDGE-LIT EXIT
Page 1 of 2
LGN1RCBRSD2
6" Surface Ceiling Mount
14.25"
(36.19 cm)
8" Surface Ceiling Mount
14.25"
(36.19 cm)
4.5"
(11.43 cm)
10.1"
(25.43 cm)
4.5"
(11.43 cm)
12. 01"
(30.51 cm)
Features
Illumination: Illumination of
the exit panel is accomplished
with the use of high-brightness
LEDs in an optical array
offering even illumination.
Average exit legend
illumination level is 25 fl
(79 cd/m2). Panel is available
in 6” or 8”, UL and NFPA
compliant lettering without a
change to the housing parts.
Housing: All housing
components are premium die-
cast aluminum construction. A
range of finishes are available
(see ordering information on
back). A bar hanger bracket
kit is standard for recessed
applications. The exit panel is
manufactured from high-impact
acrylic and silk-screened using
computer generated artwork.
All artwork meets UL and
NFPA standards for exit
signage. Universal self-stick
chevrons are standard. Panel
is available in 6” and 8” "EXIT"
legend heights. Universal
mounting configurations
include recessed ceiling mount,
surface ceiling mount, surface
end mount and surface wall
mount.
Diagnostic Electronics
(standard): 120/277 VAC
dual voltage input with surge
protection is standard on all
AC models. For emergency
operation, the charging system
is microprocessor driven with
software embedded diagnostic
routine and temperature
compensation. 120/277 VAC
input, surge protection,
brownout , AC lockout and low
voltage disconnect features are
standard.
Self-Testing Diagnostics
(optional): The diagnostic/
charging platform with self-
testing mode automatically
runs a one-minute self-test
every 30 days and a 30-minute
test on the sixth and twelfth
month. A one-minute or
90-minute test may be initiated
via the push to test switch on
the unit or by activating the
appropriate test command on
the optional IR test device.
Job Information Type:
Job Name:
Cat. No.:
Electrical Specifications:
AC Only Red:
3.8 W (120 VAC), PF 0.96
3.8 W (277 VAC), PF 0.91
AC Only Green:
4.0 W (120 VAC), PF 0.95
4.0 W (277 VAC), PF 0.90
Self-Powered Red:
4.7 W (120 VAC), PF 0.95
4.8 W (277 VAC), PF 0.97
Self-Powered Green:
4.7 W (120 VAC), PF 0.95
4.7 W (277 VAC), PF 0.99
Code Compliance
UL 924 and UL damp location
listed. NFPA 101, NEC, BOCA,
OSHA and IBC illumination
standards. Meets ADA
specifications for wall mounted
lighting fixtures. Certified
to the California Energy
Commission in accordance
with California law. NEMA
Premium certified.
Warrant y
Five-year full electronics
warranty. Five-year full plus
five-year prorated battery
warranty.
Operating Temperature
Range:
32°F (0°C) to 104°F (40°C)
Notes:
ARCHITECTURAL LED EDGE-LIT EXIT
Ordering Information
LG
Series
LG =
Architectural
Edge-Lit Exit
Accessories (order as a separate item)
SDREMOTE = Infrared Remote Test Device
BBKIT = Backbox Rough-In Kit ** (must order remainder of
produc t with LBB suf fix)
BBKITDC = Backbox Rough-In Kit with DC Option
BBKIT2CKT1 = Backbox Rough-In Kit with 2C KT1 Option
BBKIT2CKT2 = Backbox Rough- In Kit with 2CKT2 Option
PKIT12W = Pendant Kit, 12” White Finish*
PKIT12B = Pendant Kit, 12” Black Finish*
*Custom pendant lengths and colors available, consult fac tory.
**BBKIT supplied with a clear coat finish for installation above a finished ceiling
Battery
A = AC Only
N = Nickel
Cadmium
# of Faces
1 = Single
2 = Double
X = Less
Panel
4
Letter/Background
RC = Red/Clear
GC = Green/Clear
RW = Red/White
GW = Green/White
RM = Red/Mirror
GM = Green/Mirror
Housing Finish
5
A = Brushed
5
Aluminum
B = Black
W = White
N = Nickel
G = Gunmetal
BR = Ornamental
Bronze
AC = Aged Copper
VG = Velvet Green
GR = Granite
PA = Painted
Aluminum
Model Designator
Blank = AC Only
SD2 = Diagnostic
Electronics
(required with
nickel cadmium
models)
LG Series
Page 2 of 2
1
Factory Installed Options
2CKT1 = Two-Circuit 120/120 VAC (AC-only models)
2CKT2 = Two-Circuit 277/277 VAC (AC-only models)
BF = Buzzer/Flasher (self-powered models only)
BZ = Buzzer (self-powered models only)
DC = 12-48 VDC Input (AC only models)
EX = Special Input Transformer (specify voltage &
frequency)
FA = Fire Alarm Activated Flasher
FL = Flasher (self-powered models only)
LBB = Unit- Less B ackbox
NY8 = 8" Letters
T = Self-Testing Diagnostics (non-audible)
TA = Audible Self-Testing Diagnostics
SW = Special Wording (consult factor y)
2
3
2
Note
1) For self-testing models refer to options.
2) Some options may impact the UL listing. Consult factor y for specifics.
3) Required model number for units with back boxes installed on the job.
4) Order when panels are not required at time of installation. Consult factory for edge-lit panel order number.
5) Clear background only available on single face.
6" Recessed Ceiling Mount
17.2 5"
(43.81 cm)
(10.16 cm)
7.2 8"
(18.49 cm)
8" Recessed Ceiling Mount
17.2 5"
(43.81 cm)
(10.16 cm)
9.28"
(23.57 cm)
4.0"
4.0"
6" Surface End Mount
14.74 "
(37.44 cm)
(11.43 cm)
10.1"
(25.43 cm)
8" Surface End Mount
14.74 "
(37.44 cm)
(11.43 cm)
12. 01"
(30.51 cm)
4.5"
11.11"
(28.22 cm)
4.5"
13.11"
(33.3 cm)
6" Surface Wall Mount
14.25"
(36.19 cm)
2.49"
(6.325 cm)
10.1"
(25.43 cm)
8" Surface Wall Mount
14.25"
(36.19 cm)
(6.325 cm)
12. 01"
(30.51 cm)
11.11"
(28.22 cm)
2.49"
13.11"
(33.3 cm)
Philips Lightolier
e: lol.webmaster@philips.com
t: (508) 679-8131
w: www.lightolier.com
LG Series August 10, 2011
Specifications are subject to change without notice.
© Koninklijke Philips Electronics N.V., 2011. All rights reserved.