Lightolier KW8S296SL120LE User Manual

KW Industrial SL Solid Top Fluorescent KW SERIES SL
Page 1 of 2 4-1/8” Wide x 48”or 96” Lengths, Solid Top, 2 Lamp T8 or T12 Slimline
Features
• Reflectors are embossed for rigidity.
• Reflector sides are turned up for rigidity and safe handling.
• Solid top reflector, standard.
• 10% aperture reflector, optional.
• Reflectors easily installed with quarter turn fasteners. No tools required.
• 4-1/8” wide heavy duty channel of code gauge die-formed steel.
• Combination end cap/coupler requires no tools for installation.
• Suitable for individual or row mounting.
• Fully enclosed wiring.
• Multiple knockouts for convenient installation.
• Optional hangers, wire guards and aligners.
• Optional heavy duty coupling.
Dimensions
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. Copyright 2002 Lightolier Section 7/Folio Q70-50
4-5/8"
(117mm)
10-1/2” (267mm)
1-7/8" (48mm)
7/8” Dia.K.O. (4)
SIDE VIEW
7/8”(22mm)
1/2”
Dia.K.O. (2)
5-7/8”(149mm)
48” (1219mm)
6” (152mm)
4-5/8”(117mm)
1-1/8” (29mm)
4-1/8”
(105mm)
4” (102mm)
6-3/8” (162mm)
2” Dia.K.O. with
7/8”Dia.K.O.
7/8”Dia.K.O. (4)
4’ CHANNEL
96” (2438mm)
24”
(610mm)
7/8”Dia.K.O. (8)
2” Dia.K.O. with
7/8”Dia.K.O.
6-3/8” (162mm)
4-1/8”
(105mm)
4” (102mm)
6” (152mm)
4-5/8” (117mm)
1-1/8” (29mm)
8’ CHANNEL
S Hook K.O. (8)
S Hook K.O. (8)
3-1/16” (78mm)
5-7/8”(149mm)
KW Industrial SL Solid Top Fluorescent KW SERIES SL
Page 2 of 2 4-1/8” Wide x 48” or 96” Lengths, Solid Top, 2 Lamp T8 or T12 Slimline
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. Copyright 2002 Lightolier Section 7/Folio Q70-50
Job Information Type:
Photometry Model No. KW8S296SL120LE
Report No: G42322 Catalog No:
KW8S296SL120LE Lamp Type; 2F96SL Lumens Per Lamp: 5500 Total Efficiency: 90.2% CIE Type: Direct Spacing Criteria: 1.5 Shielding Angle: 180
Options & Accessories
Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF. Fluorescent Emergency Lighting System: Factory installed emergency power battery pack with charger and inverter. Suffix: EM. Stem and Canopy Sets: Suspends fixture 6”, 12”, 18” or 24” from surface. Catalog Number: ASC6 CSP (6”), ASC12 CSP (12”), ASC18 CSP (18”), ASC24 CSP (24”). Canopy Spacer: Suspends fixture 1-1/2” from surface. Order Catalog Number: AS1 CSP 4’ Wire Guard (White): Specify two for 96” fixtures. Catalog Number: AWG4W CSP Reflector Row Aligners: Two aligners are included with all 96” fixtures. For
continuous row installations, specify two additional bulk-packed aligners per reflector joint. Catalog Number: KNA. Chain Hanging Kit: Includes two 5’ heavy duty link chains with sturdy “V” hooks for fixture suspension. AH5 CSP
Twist Tee: For exposed T-bar mounting, 1-7/8” deep channel. NAH3 CSP Heavy Duty Coupler: Catalog Number: NHDC-W CSP
Specifications
Materials: Chassis parts are die-formed heavy gauge cold rolled steel, 4-1/8”
channel width.
Specifications (continued)
Reflector: Heavy duty die-formed with deep lateral embossments and return
edges for additoinal stability and uniformity and two quick release quarter turn fasteners for attachment to housing.
Ballast Cover: Code gauge steel secured with quarter turn latch. Finish: Chassis exterior—phosphate undercoating, baked white polyester
enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and C-UL.
Ordering Information
Explanation of Catalog Number. Example: KW8S296SL120LEGLR
STEM AND
CANOPY SET
ASC6 CSP (6”)
CANOPY SPACER
AC1 CSP
CHAIN
HANGING
KIT
AH5 CSP
HEAVY DUTY
COUPLING
NHDC-W CSP
TWIST TEE
NAH3
CSP
SLIDING HANGER
KIT
NAHW
CSP
FIXTURE LENGTH:
4=48" 8=96"
NUMBER OF
LAMPS IN
WIDTH:
(By Others)
2 Lamp Only
LAMP WATTS:
48SL=38w T12 Slimline
(4' Length)
59SL=59w T8 Slimline
(8' Length))
96SL=75w T12 Slimline
(8' Length)2
VOLTAGE: 120 or 277
BALLAST TYPE:
1-2 Lamp Mag. T12 LE
(Energy Savings)
1-2 Lamp Standard Electro Magnetic T12 P
<20THD <10THD
1-2 Lamp Elec. T8 SO* H
I*
*Instant Start Standard
REFLECTOR: S=Solid Top A=10% Uplight
STANDARD
INDUSTRIAL:
4-1/8" Wide:
Channel
OPTIONS: Add appropriate suffix to catalog
no. ie: (GLR)
KW
2
LER = FI - 69.1 IW - 126 BF - 0.88 Comparative yearly lighting energy cost per 1000 lumens = $3.48
coefficients of utilization- zonal cavity method
RF 20 50 30 RC 80 80 30
RW 70 50 30 50 30 10 50 30 10
1979288 858280 817977 2877973 746964 706662 3796961 645853 615651 4726052 565044 544843 5665445 504338 484237 6604839 453832 433732 7564335 413428 393328 8523931 373025 352925 9483628 342722 332722
10 45 33 26 31 25 20 30 24 20
room cavity method
Loading...