Lightolier ISF-300 User Manual

INSTRUCTION SHEET
ISF:300
INSTALLATION INSTRUCTIONS FOR 12V LOW VOLTAGE
AND 120V REMODELER
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with National Electrical Code or Canadian Electrical Code (as applicable) and local regulations. To ensure full compliance with local codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
DIA* = CEILING CUT-OUT
300MR / 400MR 300ES 301MRE - 401MRE 303MRE
07-01/Rev-03
300MR = 3-3/4" (95mm) Dia*
400MR = 4-3/4" (121mm) Dia*
1" Max. ceiling thickness
300ES = 3-3/4" (95mm) Dia*
1" Max. ceiling thickness
A. CEILING:
1. Cut an opening as indicated above. (Fig.1)
Note: Ensure that there is nothing to obstruct the installation in the ceiling.
B. WIRE-IN:
1. Open junction box cover. (Fig.2)
2. Insert the supply lead into the junction box with a BX connector (not included).
3. Ground the fixture.
4. Connect the white leads (NEUTRAL) together, and the black leads (120V) together. (Fig.3, 4 or 5)
5. Close cover. (Fig.2)
Note: Be careful not to pinch leads.
C. HOUSING:
1. Slide the power pack and the housing together into the ceiling. Snap into place. (Fig.6)
D. RESIDENCE MOUNTING FASTENERS
1. Screw both fasteners screws. (Fig.8)
OR
303MRE MOUNTING FASTENERS:
1. Place (3) holding springs, in the T slots. Slowly push downward using a short handle screwdriver, until trim is flush with ceiling, solidify with screws (3) (included), (Fig.7)
ATTENTION: Insure that the spring is placed correctly in the T slot, nice and straight then push down slowly. The spring does not have to be lowered completely in the slot.
CAUTION: The housing must not be used for temporary lighting, a protective shield is required for the lamp.
E. TRIM:
1. Install the trim using the appropriate instruction sheet.
F. TRANSFORMER / REPLACEMENT:
(Models 301MRE, 303MRE, 401MRE)
Note: Before performing maintenance on the transformer, make sure that the electrical supply to the fixture is turned off.
1. Remove the junction box cover and disconnect all wiring connected to the transformer. (Vig.9)
2. The transformer is held by double sided tape, rotate with screwdriver under the transformer to loosen it. (Fig.9)
3. Complete the connections (Fig.5) following the wiring diagram.
NOTE: WARNING RISK OF FIRE Transformer contains fixture thermal protector. Use only replacement transformer obtained from LIGHTOLIER.
FIG.1
LAMP
NEUTRAL (white)
INPUT (120V)
THERMAL
PROTECTOR
LAMP
HOUSING
301MRE = 3-3/4" (95mm) Dia* 401MR = 4-3/4" (121mm) Dia*
1" Max. ceiling thickness
SUPPLY
LEAD
COVER
INPUT (120V)
NEUTRAL (white) GROUND
WHITE
BLACK
THERMAL
PROTECTOR
LOW VOLTAGE
JUNCTION
BLACK
BLUE
SCREW
CEILING
TRANSFORMER
BOX
JUNCTION BOX
GROUND
BLACK
"T" SLOTS
RETAINING SPRINGS
NEUTRAL (white)
LOW VOLTAGE
TRANSFORMER
FIG.3 (MR)
FIG.5 (MRE)
FIG.7
303MRE = 3-3/4" (95mm) Dia*
1/2" Max. ceiling thickness
BX CONNECTOR
JUNCTION BOX
NEUTRAL
LAMP
SCREWS
FASTENERS
GROUND
WHITE
BLACK
WHITE
JUNCTION
BOX
HOUSING
JUNCTION BOX
SCREWDRIVER
INPUT (120V)
NEUTRAL (white)
BLUE
FIG.2
THERMAL
PROTECTOR
FIG.4 (ES)
POWER PACK
FIG.6
FIG.8
FIG.9