INSTRUCTION SHEETS BEFORE INSTALLING ANY PROSPEC®TRACK ITEM.
This fixture is intended for installation in accordance with the National Electrical Code and local or Federal code specifications. To assure full compliance with codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA 02720
®
INSTRUCTION SHEET NO.
IS:26060
0597 Page 1of 2
END FEED AND FLOATING CANOPY MOUNTING KIT - FLUSH AND STANDOFF VERSIONS
FOR USE WITH PROSPEC
®
SURFACE MOUNT TRACK SYSTEMS ONLY
END FEED MOUNTING INSTRUCTIONS (Flush 26060WH, BK and Standoff 26061WH, BK)
Mounting the CANOPY at the end of FEED TRACK or directly above a FEED CONNECTOR.
1. Mark CENTER LINE for TRACK through CENTER LINE of OUT­LET BOX.
2. NOTE: The CANOPY mounts to a 3 or 4” OCTAGON OUTLET BOX. The MOUNTING HOLES of the OUTLET BOX should be at 45° to the longitudinal axis of the TRACK. (Fig. 1)
3. Remove the KNOCK OUT PLATE from the FEED TRACKor CONNECTOR (retain the SCREW). (Fig. 2)
4. Prepare TAB on the PLATE ASSEMBLY as follows:
• FEED TRACK: DO NOT BREAK ANY TAB. (Fig. 2)
• POWER EXTENSION, IN-LINE, “T”, AND “ X” CONNECTORS:
BREAK THE 90° TAB OFF THE PLATE ASSEMBLY. (Fig. 3)
• “L” CONNECTOR: BREAK THE 90° TAB AND THE STRAIGHT
TAB FROM THE PLATE ASSEMBLY. (Fig. 4)
5. Attach the PLATE ASSEMBLYonto the FEED TRACK or CONNECTOR using the SCREW. (Fig. 2 & 3)
6. Mount the TRACK to the ceiling (see instruction sheet IS:26000 provided with the TRACK) passing the wires through the center of the PLATE ASSEMBLY.
7. Rotate the PLATE ASSEMBLYuntil the SLOTS are in-line with the MOUNTING HOLES on the J-BOX.
8. Secure the PLATE ASSEMBLYto the J-BOX using the THIN HEAD SCREWS. (Fig. 5)
9. Attach the GROUND WIRE on the CANOPY PLATE to the GROUND LEAD or GROUND TERMINAL in the J-BOX. (Fig. 5)
10. WHEN USING THE FLUSH CANOPY 26060WH/BK. Slide the CANOPY PLATE between the CONNECTOR and CROSS BAR on the PLATE ASSEMBLY. For added security of CANOPY PLATE: Drill a hole in CANOPY PLATEand secure to ceiling with a screw.
11. WHEN USING THE STANDOFF CANOPY 26061WH/BK Slide the CANOPY PLATE between the CROSS BARand NUT on the PLATE ASSEMBLY. Rotate the NUTto secure the CANOPY PLATE against the ceiling. (Fig. 8)
NOTE: THE CROSS BAR MUST COVER THE SLOT IN THE CANOPY PLATE AFTER ASSEMBLY.
12. Follow the instructions for wiring on the instruction sheet included with the “FEED TRACK” or “CONNECTOR”.
CAUTION: TURN OFF POWER AT FUSE BOX BEFORE
INSTALLING THE CANOPY KIT
POWER EXTENSION CONNECTOR
PLAT E
ASSEMBLY
SCREW
90 ° TA B
KNOCK OUT PLATE
FIG. 2
FIG. 3
PLAT E
ASSEMBLY
SCREW
KNOCK OUT PLATE
FEED TRACK
FIG. 4
STRAIGHT TAB
PLATE
ASSEMBLY
90 ° TA B KNOCK OUT PLATE
“L” CONNECTOR
CANOPY PLATE
GROUND WIRE
THIN HEAD
SCREW
J-BOX
FIG. 5
CROSS BAR
CROSS BAR
45 °
TRACK UNIT
LONGITUDINAL TRACK
OUTLET BOX
OUTLET BOX MOUNTING HOLE
FIG. 1
READ AND UNDERSTAND ALL TRACK, CONNECTOR, FEED-IN-KITS, AND ACCESSORY
INSTRUCTION SHEETS BEFORE INSTALLING ANY PROSPEC®TRACK ITEM.
This fixture is intended for installation in accordance with the National Electrical Code and local or Federal code specifications. To assure full compliance with codes and regulations, check with your local electrical inspector before installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA 02720
®
INSTRUCTION SHEET NO.
IS:26060
0597 Page 2of 2
FLOATING FEED MOUNTING INSTRUCTIONS (Flush 26060WH, BK and Standoff 26061WH, BK)
Mounting the CANOPY at some distance away from the end of the FEED TRACK or FEED CONNECTOR. NOTE: Hardware is supplied to mount the CANOPY a maximum
of 4 feet from the FEED CONNECTOR. DO NOT EXCEED THIS DISTANCE.
1. Mark CENTER LINE of TRACK through CENTER LINE of OUT­LET BOX.
2. NOTE: The CANOPY mounts to a 3 or 4” OCTAGON OUTLET BOX. The MOUNTING HOLES of the OUTLET BOX should be at 45° to the longitudinal axis of the TRACK. (Fig. 1)
3. Break the BARRIER off the FEED CONNECTOR or FEED TRACK. (Fig. 6)
4. Remove the DEAD END from the TRACK and retain.
5. Assembly the “U” BRACKET onto the PLATE ASSEMBLY using the FLAT HEAD SCREW. (Fig. 6)
6. Run the feed wires along the top of the TRACK and into the FEED CONNECTOR or FEED TRACK. (2 HOTS, 2 NEUTRALS, AND GROUND; MAXIMUM)
7. NOTE: USE 12 GA. COPPER THHN WIRE INCLUDING GROUND. IF STRANDED 12 GA WIRE IS USED THE ENDS MUST BE TINNED.
8. Cut the WIRE COVER to the desired length.
9. Slide the WIRE COVER (over the wires) and PLATE ASSEMBLY into the TRACK. NOTE THE POSITION OF THE 90° TAB IN RELATION TO THE FEED-IN POINT. Pass the wires through the center hole of the PLATE ASSEMBLY.
10. Secure the PLATE ASSEMBLY to the TRACK by tightening the SCREW. THE WIRE COVER MUST COVER THE ENTIRE LENGTH OF WIRES ON TOPS OF THE TRACK.
11. Mount the TRACK to the ceiling (see instruction sheet 26000 provided with the track or IS:26478). Positioning the PLATE ASSEMBLYover the J-BOX.
12. Splice the wires from the track to the wires in the J-BOX. BLACK TO BLACK, WHITE TO WHITE, AND GROUND TO GROUND.
13. Rotate the PLATE ASSEMBLY until the SLOTSare in-line with the MOUNTING HOLES on the J-BOX.
14. Secure the PLATE ASSEMBLY to the J-BOX using the THIN HEAD SCREWS. (Fig. 7)
15. Attach the GROUND WIRE on the CANOPY PLATE to the GROUND LEAD or GROUND TERMINAL in the J-BOX. (Fig. 7)
16. WHEN USING THE FLUSH CANOPY 26060WH/BK. Slide the CANOPY PLATE between the TRACK and CROSS BAR on the PLATE ASSEMBLY. For added security of CANOPY PLATE: Drill a hole in CANOPY PLATEand secure to ceiling with a screw.
17. WHEN USING THE STANDOFF CANOPY 26061WH/BK. Slide the CANOPY PLATE between the CROSS BAR and NUT on the PLATE ASSEMBLY. Rotate the NUTto secure the CANOPY PLATE against the ceiling. (Fig. 8)
18. NOTE: THE CROSSBAR MUST COVER THE SLOT IN THE CANOPY PLATE AFTER ASSEMBLY.
19. Follow the instructions for wiring on the instruction sheets included with the the “FEED TRACK” or “CONNECTOR”.
20. Assembly the DEAD END into the end of the TRACK.
FIG. 6
BARRIER
DEAD END
U BRACKET
90 ° TA B
FLAT HEAD SCREW
PLATE
ASSEMBLY
WIRE COVER
TRACK UNIT
FEED CONNECTOR
FEED IN POINT
U BRACKET
FIG. 8
TRACK UNIT
J BOX
CANOPY
PLATE
POWER EXTENSION
CONNECTOR
NUT
FIG. 7
CANOPY PLAT E
J-BOX
PLATE ASSEMBLY
WIRE COVER
POWER EXTENSION CONNECTOR
TRACK UNIT
THIN HEAD SCREW