Lightolier HDS2GLW224, HDS2GLW214 User Manual

Features
• 77.1% efficient (2 lamp, 24W).
• 72.1% efficient (2 lamp, 14W).
• Only 2-1/4" plenum depth.
• Direct/indirect appearance with soft contoured interior.
Same fixture fits both G and T ceiling types.
• Fits flush to face of slot grid (T) ceiling.
• Translucent DR acrylic linear prismatic lens.
• Tension screws secure ends to body.
• Lamp shield opens from either side.
• Ballast accessible from room side.
• Wiring access plate standard.
• Optional DALI ballast i GEN TECHNOLOGY accepts digital dimming controllers, scene controllers and automatic control devices.
• Construction meets NYC Code / Chicago Plenum available.
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 a Philips Group Section 5/Folio M33-35
Lightolier is a Philips group brand
11/08
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
HP90 Semi HDS2GLW214 or 224
Page 1 of 2 Direct/Indirect Semi-Recessed Fluorescent
2' x 2' with Acrylic Linear Prismatic Lens, 2 Lamp T5
2-1/4" (57mm)
2-5/16" (59mm)
24-1/8" (613mm)
1-9/16" X 2-13/16" Access Plate with (2) 7/8" (73mm) Dia. KO
24"
(610mm)
24" (610mm)
2-1/4" (57mm)
Mounting Methods Dimensions
exposed slot t-grid ceiling
Acoustical material by others
1-7/8"
max.
Exposed T-bar by others
9/16"
24"
Features
Lens opens from either side
T-bar by others
exposed t-grid ceiling
Exposed T-bar by others
1-1/2" max.
Acoustical material by others
15/16" *
24"
* For flush mounting when using 9/16" Exposed T-Grid
ceiling system consult factory
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 a Philips Group Section 5/Folio M33-35
Job Information Type:
Lightolier is a Philips group brand
HP90 Semi HDS2GLW214 or 224
Page 2 of 2 Direct/Indirect Semi-Recessed Fluorescent
2' x 2' with Acrylic Linear Prismatic Lens, 2 Lamp T5
Ordering Information
Explanation of Catalog Number. Example: HDS2GLW224UNVPG
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Emergency Packs are only avalable for remote mounting.
Consult factory.
For motion or light sensor.See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 24W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .77. To reduce glare the average brightness at 65° shall not exceed 3196 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 77.3%.
Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – Soft white post painted polyester powder.
Specifications (continued)
Cavity – Soft white post painted polyester powder. Rust preventative undercoating. Reflector–
Soft white post painted polyester powder. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
HD
Options:
Add appropriate suffix to catalog
no., ie: (A)
HP90
Direct/Indirect
Semi-Recessed
S
Body Style:
S = Static
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens Lamp:
(By Others)
14=T5 14W 24=T5HO 24W
(Nominal 24")
W
Reflector:
White
2
Lamp
Quantity 2=2 Lamp
Ballast Type:
<20THD <10THD
2 Lamp Elec. T5 PG ††
(14 Watt)
2 Lamp Elec. T5HO PG ††
(24 Watt)
††Program Rapid Start (UNV only)
0.0 45.0 90.0 FLUX
0 511 511 511
5 508 509 512 49 15 486 495 502 140 25 446 466 484 215 35 389 425 458 266 45 315 370 420 285 55 227 310 376 274 65 131 248 324 237 75 59 188 264 185 85 13 131 212 130 90 2 84 151
Model No. HDS2GLW214120PG
LER = FP - 58.1 IW - 30.6 BF - 1.O Comparative yearly lighting energy cost per
1000 lumens = $4.13
Report Number: G2008276 Catalog Number: HDS2GLW214120PG Lamps: (2)F14T5 Luminaire: HP90 Semi-Recessed 2' x 2'
with linear prismatic lens. Ballast: ER21120MHT Report is based on 1200 Lumens per lamp.
Efficiency: 74.1% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 23.040 23.040
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1183. 1390. 1578. 55 1012. 1382. 1676. 65 746. 1413. 1846. 75 486. 1548. 2174. 85 204. 2059. 3332.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
01797470696663666461 02716458595551575350 03645548524642504541 04584941464035443935 05544336413530393430 06493932373126353026 07473528332723322723 08433225302520292420 09402923282218272218
10 37 27 21 26 20 17 25 20 17
ZONE LUMENS % LAMP % FIXT
00-030 403 16.8 22.7 00-040 669 27.9 37.6 00-060 1228 51.2 69.0 00-090 1780 74.1 100.0
90-180 0000 0.0 000.0
00-180 1780 74.1 100.0
ZONAL LUMEN SUMMARY
Model No. HDS2GLW224120PG
LER = FP - 66.0 IW - 46.7 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $3.63
Report Number: G2008227 Catalog Number: HDS2GLW224120PG Lamps: (2) F24T5 HO Luminaire: HP90 Semi-Recessed 2' x 2'
with linear prismatic lens. Ballast: ER224120MHT Report is based on 2000 Lumens per lamp.
Efficiency: 77.1% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 23.040 23.040
0.0 45.0 90.0 FLUX
0 885 885 885
5 882 882 885 84 15 844 858 870 243 25 774 808 839 373 35 674 735 795 460 45 546 643 731 495 55 391 537 655 474 65 227 430 561 409 75 102 323 461 320 85 22 225 368 226 90 3 146 265
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2051. 2415. 2746.
55 1743. 2394. 2920.
65 1293. 2450. 3196.
75 840. 2660. 3797.
85 346. 3536. 5783.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01827773726966696664 02736660625753595551 03675750544843514743 04615043474136464036 05564537423631413531 06514033383227373127 07473629352824332824 08443326322621312521 09413024292319282319
10 39 28 22 27 21 17 26 21 17
ZONE LUMENS % LAMP % FIXT
00-030 699 17.5 22.7 00-040 1160 29.0 37.6 00-060 2129 53.2 69.0 00-090 3083 77.1 100.0
90-180 0000 00.0 000.0
00-180 3083 77.1 100.0
ZONAL LUMEN SUMMARY
Voltage:
120, 277 or
UNV=120-277
Loading...