Lightolier HDS2GLW154, HDS2GLW254 User Manual

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 a Philips Group Section 5/Folio M33-45
Lightolier is a Philips group brand
11/08
Job Information Type:
Cat. No.:
Lamp(s):
Volts/Ballast:
2-1/4" (57mm)
2-5/16" (59mm)
24" (610mm)
24"
(610mm)
48" (1219mm)
2-1/4" (57mm)
Features
• 83.6% efficient (1 lamp, 54W).
• 74.8% efficient (2 lamp, 54W).
• Only 2-1/4" plenum depth.
• Direct/indirect appearance with soft contoured interior.
Same fixture fits both G and T ceiling types.
• Fits flush to face of slot grid (T) ceiling.
• Lens encloses lamp compartment.
• Translucent DR acrylic linear prismatic lens.
• Tension screws secure ends to body.
• Lamp shield opens from either side.
• Ballast accessible from room side.
• Wiring access plate standard.
• Optional DALI ballast i GEN TECHNOLOGY accepts digital dimming controllers, scene controllers and automatic control devices.
• Construction meets NYC Code / Chicago Plenum available.
HP90 Semi HDS2GLW154 or 254
Page 1 of 2 Direct/Indirect Semi-Recessed Fluorescent
2' x 4' with Acrylic Linear Prismatic Lens, 1 or 2 Lamp T5
2-1/4" (57mm)
2-5/16" (59mm)
24" (610mm)
Mounting Methods Dimensions
exposed slot t-grid ceiling
Acoustical material by others
1-7/8"
max.
Exposed T-bar by others
9/16"
24"
Features
Lens opens from either side
T-bar by others
exposed t-grid ceiling
Exposed T-bar by others
1-1/2" max.
Acoustical material by others
15/16" *
24"
* For flush mounting when using 9/16" Exposed T-Grid
ceiling system consult factory
1-9/16" X 2-13/16" Access Plate with (2) 7/8" Dia. K.O.s
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 a Philips Group Section 5/Folio M33-45
Job Information Type:
Lightolier is a Philips group brand
HP90 Semi HDS2GLW154 or 254
Page 2 of 2 Direct/Indirect Semi-Recessed Fluorescent
2' x 4' with Acrylic Linear Prismatic Lens, 1 or 2 Lamp T5
Ordering Information
Explanation of Catalog Number. Example: HDS2GLW254UNVPG
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C. Drywall Kit: Order Catalog Number: FK92X4. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 54W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .75. To reduce glare the average brightness at 65° shall not exceed 3301 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 77.5%.
Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – Soft white post painted polyester powder. Cavity–
Soft white post painted polyester powder. Rust preventative undercoating.
Reflector – Soft white post painted polyester powder.
Specifications (continued)
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
HD
Options:
Add appropriate suffix to catalog
no., ie: (A)
HP90
Direct/Indirect
Semi-Recessed
S
Body Style:
S = Static
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens
54
Lamp:
(By Others) 54=T5 54W
(Nominal 48")
W
Reflector:
White
Lamp
Quantity 1=1 Lamp 2=2 Lamp
UNV
Ballast Type:
<20THD <10THD
1 Lamp Elec. T5 HO PG ††
(54 Watt)
2 Lamp Elec. T5 HO PG ††
(54 Watt)
††Program Rapid Start (UNV only)
0.0 45.0 90.0 FLUX
0 1053 1053 1053
5 1046 1047 1051 100 15 997 1015 1033 287 25 906 955 996 440 35 781 868 937 541 45 626 760 864 581 55 452 641 777 562 65 272 516 677 492 75 121 392 568 391 85 26 282 469 284 90 5 179 338
Model No. HDS2GLW154UNVPG
LER = FP - 60.5 IW - 60.8 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $3.97
Report Number: G2008213 Catalog Number: HDS2GLW154UNVPG Lamps: (1) F54 T5 HO Luminaire: HP90 Semi-Recessed 2' x 4'
with linear prismatic lens. Ballast: QT1X54/120PHO Report is based on 4400 Lumens per lamp.
Efficiency: 83.6% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.880 23.040
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1187. 1407. 1562. 55 1036. 1421. 1667. 65 820. 1482. 1856. 75 558. 1670. 2251. 85 271. 2473. 3547.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
01888379787471747169 02797165676157645955 03726254585247565046 04665446514439494339 05604840463934443833 06554335413429403429 07513931373126363025 08483628342823332723 09453326312521302520
10 42 30 23 29 23 19 28 22 18
ZONE LUMENS % LAMP % FIXT
00-030 827 18.8 22.5 00-040 1368 31.1 37.2 00-060 2511 57.1 68.3 00-090 3678 83.6 100.0
90-180 0000 0.0 000.0
00-180 3678 83.6 100.0
ZONAL LUMEN SUMMARY
Model No. HDS2GLW254UNVPG
LER = FP - 71.5 IW - 93.9 BF - 1.02 Comparative yearly lighting energy cost per
1000 lumens = $3.36
Report Number: G2008216 Catalog Number: HDS2GLW254UNVPG Lamps: (2) F54 T5 HO Luminaire: HP90 Semi-Recessed 2' x 4'
with linear prismatic lens Ballast: B254PUNV-D Report is based on 4400 Lumens per lamp.
Efficiency: 74.8% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.880 23.040
0.0 45.0 90.0 FLUX
0 1891 1891 1891
5 1879 1881 1888 179 15 1794 1825 1852 516 25 1635 1713 1779 789 35 1410 1556 1679 972 45 1135 1367 1553 1047 55 822 1155 1397 1014 65 502 928 1204 885 75 230 699 992 695 85 50 494 782 486 90 9 302 547
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2152. 2530. 2807.
55 1885. 2560. 2997.
65 1514. 2665. 3301.
75 1060. 2979. 3931.
85 522. 4332. 5914.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01797571706764676462 02716458605551575350 03645649524642504541 04594942464035443935 05544336413530393430 06503932373126363026 07463528332723322723 08433225312521302420 09402923282218272218
10 37 27 21 26 20 17 25 20 17
ZONE LUMENS % LAMP % FIXT
00-030 1484 16.9 22.5 00-040 2456 27.9 37.3 00-060 4517 51.3 68.6 00-090 6583 74.8 100.0
90-180 0000 00.0 000.0
00-180 6583 74.8 100.0
ZONAL LUMEN SUMMARY