Lightolier HDS2GLW128, HDS2GLW228 User Manual

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 a Philips Group Section 5/Folio M33-40
Lightolier is a Philips group brand
11/08
Job Information Type:
Cat. No.:
Lamp(s):
Volts/Ballast:
HP90 Semi HDS2GLW128 or 228
Page 1 of 2 Direct/Indirect Semi-Recessed Fluorescent
2' x 4' with Acrylic Linear Prismatic Lens, 1 or 2 Lamp T5
2-1/4" (57mm)
2-5/16" (59mm)
24" (610mm)
24"
(610mm)
48" (1219mm)
2-1/4" (57mm)
Features
• 87.0% efficient (1 lamp, 28W).
• 88.5% efficient (2 lamp, 28W).
• Only 2-1/4" plenum depth.
• Direct/indirect appearance with soft contoured interior.
Same fixture fits both G and T ceiling types.
• Fits flush to face of slot grid (T) ceiling.
• Lens encloses lamp compartment.
• Translucent DR acrylic linear prismatic lens.
• Tension screws secure ends to body.
• Lamp shield opens from either side.
• Ballast accessible from room side.
• Wiring access plate standard.
• Optional DALI ballast i GEN TECHNOLOGY accepts digital dimming controllers, scene controllers and automatic control devices.
• Construction meets NYC Code / Chicago Plenum available.
2-1/4" (57mm)
2-5/16" (59mm)
24" (610mm)
Mounting Methods Dimensions
exposed slot t-grid ceiling
Acoustical material by others
1-7/8"
max.
Exposed T-bar by others
9/16"
24"
Features
Lens opens from either side
T-bar by others
exposed t-grid ceiling
Exposed T-bar by others
1-1/2" max.
Acoustical material by others
15/16" *
24"
* For flush mounting when using 9/16" Exposed T-Grid
ceiling system consult factory
1-9/16" X 2-13/16" Access Plate with (2) 7/8" Dia. K.O.s
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 a Philips Group Section 5/Folio M33-40
Job Information Type:
Lightolier is a Philips group brand
HP90 Semi HDS2GLW128 or 228
Page 2 of 2 Direct/Indirect Semi-Recessed Fluorescent
2' x 4' with Acrylic Linear Prismatic Lens, 1 or 2 Lamp T5
Ordering Information
Explanation of Catalog Number. Example: HDS2GLW228UNVPG
HD
Options:
Add appropriate suffix to catalog
no., ie: (A)
HP90
Direct/Indirect
Semi-Recessed
S
Body Style:
S = Static
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens
28
Lamp:
(By Others)
28=T5 288W
(Nominal 48")
W
Reflector:
White
Lamp
Quantity 1=1 Lamp 2=2 Lamp
Ballast Type:
<20THD <10THD
*1 or 2 Lamp Elec. T5 PI
(28 Watt)
*1 or 2 Lamp Elec. T5 PG ††
(28 Watt)
*2-Lamp Elect. T5 VY**
(28 Watt) .95/.35 Bilevel Step Ballast
†Instant Start (120, 227 or UNV)
††Program Rapid Start (UNV only) *WA = Linear T5 Instant Start Less than 10 THD
56 Input Watts 0.93 Ballast Factor 120V or 277V only.
**.35 20THD / .95 10 THD
0.0 45.0 90.0 FLUX
0 1396 1397 1396
5 1388 1390 1394 132 15 1325 1347 1368 381 25 1207 1266 1315 583 35 1042 1150 1241 718 45 840 1011 1150 775 55 608 855 1034 751 65 370 688 892 655 75 170 517 729 513 85 37 363 573 357 90 7 222 404
Model No. HDS2GLW128UNVPG
LER = FP - 74.7 IW - 33.3 BF - 1.04 Comparative yearly lighting energy cost per
1000 lumens = $3.21
Report Number: G2008221 Catalog Number: HDS2GLW128UNVPG Lamps: (1) F28 T5 Luminaire: HP90 Semi-Recessed 2' x 4'
with linear prismatic lens. Ballast: ICN-2S28 Report is based on 2750 Lumens per lamp.
Efficiency: 87.0% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.880 23.040
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1593. 1871. 2079. 55 1394. 1895. 2218. 65 1116. 1976. 2446. 75 783. 2203. 2889. 85 386. 3183. 4333.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01948883827975797673 02847669716560686359 03766658615550595349 04695849544742524641 05645143484136474035 06594638443631423631 07544233393227383227 08513830362924352924 09473527332622322622
10 44 32 25 31 24 20 30 24 20
ZONE LUMENS % LAMP % FIXT
00-030 1097 19.9 22.5 00-040 1815 33.0 37.3 00-060 3340 60.7 68.7 00-090 4866 88.5 100.0
90-180 0000 0.0 000.0
00-180 4866 88.5 100.0
ZONAL LUMEN SUMMARY
Model No. HDS2GLW228120WA
LER = FP - 83.7 IW - 54.1 BF - 0.93 Comparative yearly lighting energy cost per
1000 lumens = $2.87
Report Number: G2008223 Catalog Number: HDS2GLW228120WA Lamps: (2) F28 T5 Luminaire: HP90 Semi-Recessed 2' x 4'
with linear prismatic lens. Ballast: ST232120E (WA) Report is based on 2750 Lumens per lamp.
Efficiency: 88.5% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.880 23.040
0.0 45.0 90.0 FLUX
0 679 679 679
5 675 676 678 64 15 645 657 668 186 25 587 619 645 285 35 507 563 607 351 45 408 495 561 378 55 295 417 505 366 65 179 336 440 320 75 81 256 370 255 85 18 184 307 187 90 4 121 225
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 774. 916. 1014.
55 676. 924. 1083.
65 540. 965. 1206.
75 373. 1091. 1466.
85 188. 1614. 2322.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01928782817774777471 02837467696459666258 03756456605448585248 04685748534641514540 05635042474035463934 06584537433630413530 07534133393227373126 08503729352924342824 09463427322621322521
10 43 31 24 30 24 19 29 23 19
ZONE LUMENS % LAMP % FIXT
00-030 535 19.5 22.4 00-040 886 32.2 37.1 00-060 1630 59.3 68.1 00-090 2392 87.0 100.0
90-180 0000 00.0 000.0
00-180 2392 87.0 100.0
ZONAL LUMEN SUMMARY
Voltage:
120, 277 or
UNV=120-277
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C. Drywall Kit: Order Catalog Number: FK92X4. Electrical Wiring Options: Consult factory. For motion or light sensor.See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 28W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .88. To reduce glare the average brightness at 65° shall not exceed 2446 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 77.6%.
Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – Soft white post painted polyester powder. Cavity –
Soft white post painted polyester powder. Rust preventative undercoating.
Reflector – Soft white post painted polyester powder.
Specifications (continued)
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org