Lightolier H9S2GLR132, H9S2GLR232 User Manual

HP90 Recessed Fluorescent H9S2GLR132 or 232
Page 1 of 2 Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens
Static, 2 Lamp T8
Features
• 84.6% efficient (2 lamp, 28W).
• 80.0% efficient (1 lamp, 28W).
• Direct/indirect appearance with soft contoured interior.
• Lens encloses lamp compartment.
• Translucent DR acrylic linear prismatic lens.
• Tension screws secure ends to body.
Same fixture fits both G and T ceiling types.
• Lamp shield opens from either side.
• 95% reflective specular aluminum reflector.
• Ballast accessible from room side.
• Can be continuous row mounted.
• Wiring access plate standard.
• Optional DALI ballast iGEN TECHNOLOGY accepts digital dimming controllers, scene controllers and automatic control devices.
• Construction to meet NYC Code or Chicago Plenum available.
Mounting Methods Dimensions
Exposed T-bar by others
1-1/2" max.
Acoustical material by o hers
15/16" *
24"
exposed t-grid ceiling
* For flush mounting when using 9/16" Exposed T-Grid
ceiling system consult factory
built-in earthquake clips
Exposed T-bar by o hers
1-7/8"
max.
Acoustical material by others
24"
exposed slot t-grid ceiling
fully enclosed lamp compartment
9/16"
5"
(127mm)
5" (127mm)
24" (610mm)
2-1/2"
(64mm)
2" x 2-1/2" Access Plate with (2) 7/8" dia. K.O.
48" (1219mm)
Job Information Type:
Job Name:
Cat. No.:
10/07
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company
Section 5/Folio M32-13
HP90 Recessed Fluorescent H9S2GLR132 or 232
Page 2 of 2 Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens
Static, 2 Lamp T8
Model No. H9S2GLR132UNVHI
LER = FP - 74.8 IW - 26.66 BF - 0.88 Comparative yearly lighting ene gy cost per
1000 lumens = $3.21
Report Number: G2007123 Catalog Number: H9S2GLR132UNVHI Lamps: (1) F28 T8 Luminaire: HP90 2' x 4' with linear
prismatic lens. Ballast: GE-132-MAX-N/ULTRA Report is based on 2725 Lumens per lamp. Efficiency: 80%
CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.800 22.800
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1 86 82 79 77 74 72 74 72 70 2 78 71 65 67 62 58 64 60 57 3 71 62 55 58 53 48 56 51 47 4 64 54 47 51 45 40 49 44 40 5 59 48 41 46 39 35 44 39 34 6 54 43 36 41 35 30 40 34 30 7 50 39 32 37 31 26 36 30 26 8 47 36 29 34 28 24 33 27 23 9 44 33 26 31 25 21 30 25 21
10 41 30 24 29 23 19 28 23 19
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 789. 942. 1069. 55 718. 973. 1165. 65 592. 1025. 1337. 75 447. 1159. 1429. 85 309. 509. 370.
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 659 659 659
5 654 658 660 63
15 628 643 655 182
25 578 612 641 282
35 507 562 609 351
45 415 495 562 380
55 306 415 497 365
65 186 322 420 311
75 86 223 275 208
85 20 33 24 39
90 332
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
0- 30 526 19 3 24 1 0- 40 877 32 2 40 2 0- 60 1623 59 6 74.4 0- 90 2180 80 0 100 0
90-180 0 0 0 0 0
0-180 2180 80 0 100 0
Model No. H9S2GLR232UNVHI
LER = FP - 73.6 IW - 55.1 BF - 0.88 Comparative yearly lighting ene gy cost per
1000 lumens = $3.26
Report Number: G2007007 Catalog Number: H9S2GLR232UNVHI Lamps: (2) F28 T8 Luminaire: HP90 2' x 4' with linear
prismatic lens. Ballast: GE-232-MAX-N/ULTRA Report is based on 2725 Lumens per lamp. Efficiency: 84.6%
CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.800 22.800
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
1 92 87 84 82 79 76 79 76 74 2 83 76 70 71 66 62 68 64 61 3 75 66 59 62 56 52 60 55 51 4 69 58 50 55 49 44 53 47 43 5 63 52 44 49 42 38 47 42 37 6 58 47 39 44 38 33 43 37 32 7 54 42 34 40 34 29 39 33 29 8 50 38 31 37 30 26 36 30 25 9 47 35 28 34 27 23 33 27 23
10 44 32 26 31 25 21 30 25 21
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1891. 2179. 2413. 55 1704. 2208. 2574. 65 1416. 2264. 2759. 75 1072. 2379. 2749. 85 666. 1050. 683.
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 1481 1481 1481
5 1471 1474 1478 140
15 1421 1429 1446 404
25 1298 1344 1398 620
35 1131 1219 1301 763
45 921 1061 1175 814
55 673 872 1006 767
65 412 659 803 629
75 191 424 490 394
85 40 63 41 77
90 333
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
0- 30 1165 21.4 25 3 0- 40 1927 35.4 41 8 0- 60 3508 64.4 76 1 0- 90 4609 84 6 100 0
90-180 0 0 0 0 0
0-180 4609 84 6 100 0
Ordering Information
Explanation of Catalog Number. Example: H9S2GLR232UNVHI
HP90
Direct/Indi ect
Recessed
H9
HY
HN
S
Body Style:
S = Static
Standard HP90
For NYC Code – I B.E.W. Manufactured
For NYC Code – Local 3 Manufactu ed
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Ac ylic Lens
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X4. Electrical Wiring Options: Consult factory. For motion or light sensor. See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 28W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .87. To reduce glare the average brightness at 65° shall not exceed 2759 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.7%.
Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – baked white polyester enamel. Cavity – baked
white polyester enamel. Rust preventative undercoating. Reflector – low irides­cence specular aluminum 95% reflectance.
R
Reflector:
Specular
Aluminum
Lamp
Quantity 1=1 Lamp 2=2 Lamp
32
Lamp:
(By Others)
32 =T8 32W*
(Nominal 48")
* 28W T8 available
Voltage:
120, 277 or
UNV=120-277
Ballast Type:
1 or 2 Lamp Elec. T8 SO * H LOL Dimming T8 PS
*Instant Start Standard Other dimming options. Consult factory.
NOTE: For T8 UNV, you must use H
<20THD <10THD
I
Ballast Code.
Specifications (continued)
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company
Section 5/Folio M32-13
Options:
Add appropriate suffix to catalog
no., ie: (GLR)
I *