Lightolier H9S2GLR128, H9S2GLR228 User Manual

Features
• Can provide 54.6 maintained footcandles of balanced brightness illumination at only .68 watts per square foot.
• 87.2% efficient (1 lamp, 28W).
• 90.4% efficient (2 lamp, 28W).
• Direct/indirect appearance with soft contoured interior.
• Lens encloses lamp compartment.
• Translucent DR acrylic linear prismatic lens.
Same fixture fits both G and T ceiling types.
• Fits flush to face of slot grid (T) ceiling types.
• Lamp shield opens from either side.
• 95% reflective specular aluminum reflector.
• Ballast accessible from room side.
• Can be continuous row mounted.
• Wiring access plate standard.
• Optional DALI ballast i GEN TECHNOLOGY accepts digital dimming commands from computers, scene controllers and automatic control devices.
• Construction to meet NYC Code or Chicago Plenum available.
Mounting Methods Dimensions
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
11/06
HP90 Recessed Fluorescent H9S2GLR228 or 128
Page 1 of 2 Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens
Static, 1 or 2 Lamp T5
24" (610mm)
5"
(127mm)
2-1/2"
(64mm)
2" x 2-1/2" Access Plate with (2) 7/8" dia. K.O.
48" (1219mm)
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 5/Folio M32-10
5" (127mm)
24" (610mm)
5"
(127mm)
5" (127mm)
exposed t-grid ceiling
exposed slot t-grid ceiling
Acoustical material by others
Exposed T-bar by others
1-1/2"
max.
Acoustical material by others
15/16"
24"
1-7/8"
max.
Exposed T-bar by others
9/16"
24"
built-in earthquake clips
fully enclosed lamp compartment
HP90 Recessed Fluorescent H9S2GLR228 or 128
Page 2 of 2 Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens
Static, 1 or 2 Lamp T5
Job Information Type:
Ordering Information
Explanation of Catalog Number. Example: H9S2GLR128120WAGLR
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X4. Electrical Wiring Options: Consult factory. For motion or light sensor. See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 28W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .94. To reduce glare the average brightness at 65° shall not exceed 2574 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 73.8%.
Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat
white acrylic enamel. Phosphate undercoating. Reflector – low iridescence specular aluminum 95% reflectance.
Specifications (continued)
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Options:
Add appropriate suffix to catalog
no., ie: (GLR)
HP90
Direct/Indirect
Recessed
S
Body Style:
S = Static
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens
28
Lamp:
(By Others)
28=T5 288W
(Nominal 48")
R
Reflector:
Specular
Aluminum
Lamp
Quantity 1=1 Lamp 2=2 Lamp
Ballast Type:
<
20THD <10THD
*1 or 2 Lamp Elec. T5 PI
(28 Watt)
*1 or 2 Lamp Elec. T5 PG ††
(28 Watt)
*2-Lamp Elect. T5 VY**
(28 Watt) .95/.35 Bilevel Step Ballast
†Instant Start (120, 227 or UNV)
††Program Rapid Start (UNV only) *WA = Linear T5 Instant Start Less than 10 THD
56 Input Watts 0.93 Ballast Factor 120V or 277V only.
**.35 20THD / .95 10 THD
0.0 45.0 90.0 FLUX
0 1632 1632 1632
5 1621 1634 1645 156
15 1561 1598 1621 451
25 1448 1511 1568 697
35 1278 1386 1442 857
45 1048 1169 1202 886
55 778 891 941 789
65 506 642 749 635
75 250 427 478 412
85 51 72 60 88
90 555
Model No. H9S2GLR128UNVPG
LER = FP - 75.8 IW - 31.55 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $3.16
Report Number: G2006156 Catalog Number: H9S2GLR128UNVPG Lamps: F28 T5 Luminaire: HP90 2' x 4' with linear
prismatic lens. Ballast: QTP 2X28 T5/UNV-PSN Report is based on 2750 Lumens per lamp. Efficiency: 87.2%
CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.760 23.760
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2152. 2401. 2468. 55 1970. 2256. 2382. 65 1739. 2206. 2574. 75 1403. 2396. 2682. 85 850. 1200. 1000.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01989490888582848279 02898175767167736966 03817163676156645955 04746355595347575147 05685648534641514540 06635042484136464035 07584638433732423631 08544234403328393228 09503831373025363025
10 47 35 28 34 27 23 33 27 23
ZONE LUMENS % LAMP % FIXT
00-030 1305 23.7 26.2 00-040 2162 39.3 43.5 00-060 3837 69.8 77.2 00-090 4972 90.4 100.0
90-180 0000 0.0 000.0
00-180 4972 90.4 100.0
ZONAL LUMEN SUMMARY
Model No. H9S2GLR228120WA
LER = FP - 84.3 IW - 54.6 BF - 0.93 Comparative yearly lighting energy cost per
1000 lumens = $2.85
Report Number: G2006010 Catalog Number: H9S2GLR228120WA Lamps: F28T5 Luminaire: HP90 2' x 4' with linear
prismatic lens. Ballast: WA Report is based on 2750 Lumens per lamp.
Efficiency: 90.4% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.800 22.800
0.0 45.0 90.0 FLUX
0 877 877 877
5 868 876 884 84
15 843 860 868 242
25 792 794 785 364
35 713 672 658 424
45 592 528 536 418
55 420 386 424 359
65 239 266 352 280
75 102 183 254 188
85 20 31 28 38
90 222
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1143. 1020. 1035. 55 1000. 919. 1009. 65 772. 859. 1137. 75 538. 965. 1340. 85 313. 486. 439.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01959187858280827977 02867973747066716864 03797062666055635854 04726254585247565147 05665547524641514541 06615042474136464036 07574538433732423632 08534134403329393328 09503831363026363026
10 47 35 28 34 28 24 33 27 23
ZONE LUMENS % LAMP % FIXT
00-030 690 25.1 28.8 00-040 1115 40.5 46.5 00-060 1892 68.8 78.9 00-090 2398 87.2 100.0
90-180 0000 00.0 000.0
00-180 2398 87.2 100.0
ZONAL LUMEN SUMMARY
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 5/Folio M32-10
Voltage:
120, 277 or
UNV=120-277
H9
Standard HP90
HY
For NYC Code – I.B.E.W. Manufactured
HN
For NYC Code – Local 3 Manufactured