Lightolier H9S2GLR224, H9S2GLR214UNVPG, H9S2GLR224UNVPG Specification

HP90 Recessed Fluorescent H9S2GLR214 or 224
Page 1 of 2 Direct/Indirect – 2' x 2' with Acrylic Linear Prismatic Lens
Static, 2 Lamp T5
Features
• 83.2% efficient (2 lamp, 14W).
• 80.3% efficient (2 lamp, 24W).
• Direct/indirect appearance with soft contoured interior.
• Translucent DR acrylic high light transmission linear prismatic lens.
• Tension screws secure ends to body.
Same fixture fits both G and T ceiling types.
• Fits flush to face of slot grid (T) ceiling types.
• Lamp shield opens from either side.
• 95% reflective specular aluminum reflector.
• Ballast accessible from room side.
• Built-in earthquake clips.
• Can be continuous row mounted.
• Wiring access plate standard.
• Optional DALI ballast i GEN TECHNOLOGY accepts digital dimming controllers, scene controllers and automatic control devices.
• Construction to meet NYC Code or Chicago Plenum available.
Mounting Methods Dimensions
Exposed T-bar by others
1-1/2" max.
Acoustical material by others
15/16" *
24"
exposed t-grid ceiling
* For flush mounting when using 9/16" Exposed T-Grid
ceiling system consult factory
built-in earthquake clips
24"
exposed slot t-grid ceiling
fully enclosed lamp compartment
Exposed T-bar by others
1-7/8"
max.
9/16"
Acoustical material by others
* If emergency pack or 2nd ballast are used access is gained through the
adjacent ceiling tile.
5" (127mm)
24" (610mm)
2-1/2"
(64mm)
2" x 2-1/2" Access Plate with (2) 7/8" dia. K.O.
24" (610mm)
Job Information Type:
Job Name:
5"
(127mm)
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 11/11 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © Philips Group
Cat. No.:
Lamp(s):
Volts/Ballast:
Section 5/Folio M32-15 Rev.C
HP90 Recessed Fluorescent H9S2GLR214 or 224
Page 2 of 2 Direct/Indirect – 2' x 2' with Acrylic Linear Prismatic Lens
Static, 2 Lamp T5
Model No. H9S2GLR214UNVPG
LER = FP - 68.1 IW - 31.1 BF - 1.06 Comparative yearly lighting energy cost per
1000 lumens = $3.53
Report Number: G2010021 Catalog Number: H9S2GLR214UNVPG Lamps: (2) F14T5 Luminaire: HP90 2' x 2' with linear
prismatic lens. Ballast: ICN-2S28 Advanced Report is based on 1200 Lumens per lamp.
Efficiency: 83.2% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 22.800 22.800
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 90 86 82 80 78 75 77 75 73 02 81 74 68 70 65 61 67 63 59 03 74 65 57 61 55 50 58 54 50 04 67 57 49 54 47 43 52 46 42 05 62 51 43 48 41 36 46 41 36 06 57 45 38 43 37 32 42 36 31 07 53 41 34 39 33 28 38 32 28 08 49 37 30 36 29 25 35 29 25 09 46 34 27 33 27 22 32 26 22
10 43 32 25 30 24 20 29 24 20
0
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 622 622 622
5 620 620 623 59
15 595 605 614 171
25 548 572 593 264
35 481 521 559 326
45 397 456 507 351
55 299 375 440 333
65 198 184 364 280
75 100 180 226 178
85 21 27 20 35
90 222
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 494 20.6 24.7 00-040 820 34.2 41.1 00-060 1504 62.7 75.3 00-090 1997 83.2 100.0
90-180 0000 0.0 000.0
00-180 1997 83.2 100.0
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1656. 1902. 2115. 55 1538. 1928. 2263. 65 1382. 1982. 2540. 75 1140. 2051. 2575. 85 711. 917. 677.
Model No. H9S2GLR224UNVPG
LER = FP - 57.2 IW -{.{ BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $4.19
Report Number: G2007082 Catalog Number: H9S2GLR224UNVPG Lamps: (2) F24T5 HO Luminaire: HP90 2' x 2' with linear
prismatic lens. Ballast: QTP2X39-24T5HO/UNV Osram Report is based on 1760 Lumens per lamp.
Efficiency: 80.3% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 22.800 22.800
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 87 83 79 78 75 73 75 72 70 02 79 72 66 67 63 59 65 61 58 03 71 63 56 59 53 49 57 52 48 04 65 55 48 52 46 41 50 45 41 05 60 49 42 46 40 35 45 39 35 06 55 44 37 42 36 31 40 35 31 07 51 40 33 38 32 27 37 31 27 08 47 36 29 35 29 24 34 28 24 09 44 33 26 32 26 22 31 25 22
10 41 31 24 29 24 20 29 23 20
0
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 894 894 894
5 889 890 893 85
15 852 867 880 245
25 781 818 848 377
35 687 744 800 465
45 547 651 732 499
55 397 538 642 473
65 246 406 527 393
75 114 253 326 246
85 26 37 29 47
90 333
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 706 20.1 25.0 00-040 1171 33.3 41.4 00-060 2143 60.9 75.8 00-090 2828 80.3 100.0
90-180 0000 00.0 000.0
00-180 2828 80.3 100.0
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2081. 2477. 2785. 55 1862. 2523. 3011. 65 1566. 2584. 3354. 75 1185. 2630. 3388. 85 802. 1142. 895.
0
Ordering Information
Explanation of Catalog Number. Example: H9S2GLR224UNVPG
R
Reflector:
Specular
Aluminum
HP90
Direct/Indirect
Recessed
H9
HY
S
Body Style:
S = Static
Standard HP90
For NYC Code – I.B.E.W. Manufactured
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens Lamp:
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C. Drywall Kit: Order Catalog Number: FK92X2 . Electrical Wiring Options: Consult factory. For motion or light sensor. See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 14W luminaires in a room cavity ratio of 1,
with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .86. To reduce glare the average brightness at 65° shall not exceed 2540 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 75.3%.
Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens.
2
Lamp
Quantity 2=2 Lamp
(By Others)
14=T5 14W 24=T5HO 24W
(Nominal 24")
Specifications (continued)
Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white
acrylic enamel. Phosphate undercoating. Reflector – low iridescence specular alu­minum .95% reflectance. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Job Information Type:
Voltage:
120, 277 or
UNV=120-277
Ballast Type:
2 Lamp Elec. T5 PG ††
(14 Watt)
2 Lamp Elec. T5HO PG ††
(24 Watt)
††Program Rapid Start (UNV only)
<10THD
Options:
Add appropriate suffix to catalog
no., ie: (A)
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 11/11 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © Philips Group
Section 5/Folio M32-15 Rev.C