Lightolier H9S2GLR1FT User Manual

Features
• 72.9% efficient.
• Direct/indirect appearance with soft contoured interior.
• Lens encloses lamp compartment.
• Translucent DR acrylic linear prismatic lens.
• Tension screws secure ends to body.
• Fits flush to face of slot grid (T) ceiling types.
• Lamp shield opens from either side.
• 95% reflective specular aluminum reflector.
• Ballast accessible from room side.
• Built-in earthquake clips.
• Can be continuous row mounted.
• Wiring access plate standard.
• Optional DALI ballast i GEN TECHNOLOGY accepts digital dimming controllers, scene controllers and automatic control devices.
• Construction to meet NYC Code or Chicago Plenum available.
Mounting Methods Dimensions
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
11/06
HP90 Recessed Fluorescent H9S2GLR1FT
Page 1 of 2 Direct/Indirect – 2' x 2' with Acrylic Linear Prismatic Lens
Static, 1 Lamp TT5
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 5/Folio M32-16
exposed t-grid ceiling
exposed slot t-grid ceiling
Acoustical material by others
Exposed T-bar by others
1-1/2"
max.
Acoustical material by others
15/16"
24"
1-7/8"
max.
Exposed T-bar by others
9/16"
24"
built-in earthquake clips
24" (610mm)
5"
(127mm)
5" (127mm)
2-1/2"
(64mm)
2" x 2-1/2" Access Plate with (2) 7/8" dia. K.O.
24" (610mm)
fully enclosed lamp compartment
HP90 Recessed Fluorescent H9S2GLR1FT
Page 2 of 2 Direct/Indirect – 2' x 2' with Acrylic Linear Prismatic Lens
Static, 1 Lamp TT5
Job Information Type:
Ordering Information
Explanation of Catalog Number. Example: H9S2GLR1FTUNVPR
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10.
Specifications
Performance: In an installation of 1 lamp 40W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .96. To reduce glare the average brightness at 65° shall not exceed 2617 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 69.5%.
Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat
white acrylic enamel. Phosphate undercoating. Reflector – low iridescence specular aluminum 95% reflectance. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Options:
Add appropriate suffix to catalog
no., ie: (GLR)
HP90
Direct/Indirect
Recessed
S
Body Style:
S = Static
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens
FT
Lamp:
(By Others)
R
Reflector:
Specular
Aluminum
1
Lamp
Quantity 1=1 Lamp
Ballast Type:
<20THD <10THD
1 Lamp Elec. TT5 SB* IB**
(40 Watt)
1 Lamp Elec. TT5 PR†
(40 Watt)
1 Lamp Elec. TT5 BE*
(50 Watt)
1 Lamp Elec. TT5 –BF*
(55 Watt)
LOL Dimming TT5 PB *Instant Start Standard. Other dimming options. Consult factory.
NOTE:
For TT5 40W UNV, you must use PR Ballast Code. †Program Rapid Start
0.0 45.0 90.0 FLUX
0 876 876 876
5 868 872 876 83
15 836 841 845 238
25 776 776 772 357
35 685 665 646 416
45 560 518 528 410
55 400 373 413 348
65 230 248 318 260
75 97 149 195 155
85 19 24 19 31
90 222
Model No. H9S2GLR1FTUNVPR
LER = FP - 61.2 IW - 37.55 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $3.92
Report Number: G2006149 Catalog Number: H9S2GLR1FTUNVPR Lamps: F40BX/SPX30/IS Luminaire: HP90 2' x 2' with linear
prismatic lens. Ballast: C240PUNVHP-B/UNV Report is based on 3150 Lumens per lamp.
Efficiency: 72.9% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 23.760 23.760
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2174. 2011. 2049. 55 1914. 1789. 1976. 65 1494. 1611. 2065. 75 1029. 1580. 2068. 85 598. 765. 598.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01807673716967696765 02736762635956605754 03665953555147534946 04615246494440484340 05564740443935433840 06524236403531393430 07483832373127363127 08453529342824332824 09423226312622302522
10 39 30 24 29 24 20 28 23 20
ZONE LUMENS % LAMP % FIXT
00-030 678 21.5 29.5 00-040 1093 34.7 47.6 00-060 1851 58.8 80.6 00-090 2296 72.9 100.0
90-180 0000 0.0 000.0
00-180 2296 72.9 100.0
ZONAL LUMEN SUMMARY
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 5/Folio M32-16
Voltage:
120, 277 or
UNV=120-277
H9
Standard HP90
HY
For NYC Code – I.B.E.W. Manufactured
HN
For NYC Code – Local 3 Manufactured
Loading...