Lightolier H9S2GLR154, H9S2GLR154UNVPG, H9S2GLR254UNVPG Specification

Features
• 84.6% efficient (2 lamp, 54W).
• 89.7% efficient (1 lamp, 54W).
Direct/indirect appearance with soft contoured interior.
• Lens encloses lamp compartment.
• Translucent DR acrylic high light transmission linear prismatic lens.
• Tension screws secure ends to body.
• Fits flush to face of slot grid (T) ceiling types.
• Lamp shield opens from either side.
• 95% reflective specular aluminum reflector.
• Ballast accessible from room side.
Built-in earthquake clips.
• Can be continuous row mounted.
• Wiring access plate standard.
• Optional DALI ballast i GEN TECHNOLOGY accepts digital dimming controllers, scene controllers and automatic control devices.
• Construction to meet NYC Code or Chicago Plenum available.
Mounting Methods Dimensions
HP90 Recessed Fluorescent H9S2GLR254 or 154
Page 1 of 2 Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens
Static, 1 or 2 Lamp T5
24" (610mm)
5"
(127mm)
2-1/2"
(64mm)
2" x 2-1/2" Access Plate with (2) 7/8" dia. K.O.
48" (1219mm)
exposed slot t-grid ceiling
Acoustical material by others
1-7/8"
max.
Exposed T-bar by others
9/16"
2
4"
built-in earthquake clips
24" (610mm)
5
"
(127mm)
5" (127mm)
5" (127mm)
fully enclosed lamp compartment
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 12/10 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © Philips Group
Section 5/Folio M32-11 Rev. A
exposed t-grid ceiling
Exposed T-bar by others
1-1/2" max.
Acoustical material by others
15/16" *
24"
* For flush mounting when using 9/16" Exposed T-Grid
ceiling system consult factory
HP90 Recessed Fluorescent H9S2GLR254 or 154
Page 2 of 2 Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens
Static, 1 or 2 Lamp T5
odel No. H9S2GLR154UNVPG
M
LER = FP - 66.5 IW - 61.9 BF - 1.02 Comparative yearly lighting energy cost per
1000 lumens = $3.61
Report Number: G2010216
atalog Number: H9S2GLR154UNVPG
C Lamps: F54 T5 HO
uminaire: HP90 2' x 4' with linear
L
prismatic lens.
allast: Advance ICN-2S54
B
eport is based on 4500 Lumens per lamp.
R Efficiency: 89.7% CIE Type-Direct-Indirect
lane: 0-Deg 90-Deg
P Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg
uminous Length: 46.920 22.920
L
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 92 92 88 86 83 80 83 80 78 02 87 80 73 75 69 65 72 67 64 03 79 69 62 65 59 54 63 57 53 04 72 61 53 57 51 45 55 49 45 05 66 54 46 51 44 39 49 43 38 06 61 49 40 46 39 34 45 38 34 07 57 44 36 42 35 30 41 34 30 08 53 40 33 38 31 27 37 31 26 09 49 37 29 35 28 24 34 28 24
10 46 34 27 32 26 22 32 26 21
0
ANDELA DISTRIBUTION
C
0.0 45.0 90.0 FLUX
0 1234 1235 1235
5 1226 1231 1237 117
15 1179 1208 1233 342
5 1088 1151 1202 530
2
35 957 1051 1121 655
45 791 913 998 698
55 601 750 852 661
65 402 576 713 564
75 207 402 474 384
85 49 68 44 85
90 000
ONAL LUMEN SUMMARY
Z
ZONE LUMENS % LAMP % FIXT
00-030 989 22.0 24.5
0-040 1644 36.5 40.7
0 00-060 3002 66.7 74.4 00-090 4036 89.7 100.0
0-180 0000 0.0 000.0
9
00-180 4036 89.7 100.0
LUMINANCE DATA IN CANDELA/SQ. METER
VERAGE AVERAGE AVERAGE AVERAGE
A
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1612. 1860. 2034. 55 1510. 1884. 2140. 65 1371. 1964. 2431. 75 1152. 2238. 2639.
5 810. 1124. 727.
8
Model No. H9S2GLR254UNVPG
ER = FP - 66.5 IW - 112.39 BF - 1.0
L Comparative yearly lighting energy cost per
1000 lumens = $3.61
eport Number: G2006118
R Catalog Number: H9S2GLR254UNVPG
amps: F54 T5 HO
L Luminaire: HP90 2' x 4' with linear
rismatic lens.
p Ballast: B254UNV-E Report is based on 4400 Lumens per lamp.
fficiency: 84.6%
E CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.4 Shielding Angles: 90 90
lane: 0-Deg 90-Deg
P Luminous Length: 46.800 22.800
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 92 88 84 82 79 77 79 77 74 02 83 76 70 71 67 63 69 65 61 03 76 67 59 63 57 52 60 56 51 04 69 59 51 56 49 44 54 48 44 05 64 52 45 50 43 38 48 42 38 06 59 47 39 45 38 33 43 37 33 07 54 43 35 41 34 29 39 34 29 08 50 39 32 37 31 26 36 30 26 09 47 36 29 34 28 24 33 27 23
10 44 33 26 31 25 21 31 25 21
0
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 2340 2340 2340
5 2320 2339 2354 223
15 2228 2326 2406 658
5 2079 2280 2417 1044
2
35 1851 2134 2220 1303
45 1548 1790 1827 1348
55 1173 1345 1428 1197
65 771 963 1099 950
75 383 625 665 597
85 75 95 60 125
90 000
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 1926 21.9 25.9 00-040 3229 36.7 43.4 00-060 5774 65.6 77.5 00-090 7446 84.6 100.0
90-180 0000 00.0 000.0
00-180 7446 84.6 100.0
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 3179. 3676. 3752.
5 2970. 3405. 3615.
5 65 2649. 3309. 3776. 75 2149. 3507. 3731.
5 1250. 1583. 1000.
8
0
Ordering Information
Explanation of Catalog Number. Example: H9S2GLR254UNVPG
R
Reflector:
Specular
Aluminum
HP90
Direct/Indirect
Recessed
H9
HY
S
Body Style:
S = Static
Standard HP90
For NYC Code – I.B.E.W. Manufactured
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C. Drywall Kit: Order Catalog Number: FK92X4. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 54W luminaires in a room cavity ratio of 1,
with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .88. To reduce glare the average brightness at 65° shall not exceed 3776 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.1%.
Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens.
54
Lamp
Quantity 1=1 Lamp 2=2 Lamp
Specifications (continued)
Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white
acrylic enamel. Rust preventative undercoating. Reflector – low iridescence specular aluminum 95% reflectance. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Job Information Type:
Lamp:
(By Others) 54=T5 54W
(Nominal 48")
Voltage:
120, 277 or
UNV=120-277
Ballast Type:
1 Lamp Elec. T5 HO PG ††
(54 Watt)
2 Lamp Elec. T5 HO PG ††
(54 Watt)
††Program Rapid Start (UNV only)
<10THD
Options:
Add appropriate suffix
to catalog no., ie: (A)
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 12/10 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © Philips Group
Section 5/Folio M32-11 Rev. A
Loading...