Features
• 77.9% efficient (2 lamp, 54W).
• 79.1% efficient (1 lamp, 54W).
• Direct/indirect appearance with soft contoured interior.
• Lens encloses lamp compartment.
• Translucent DR acrylic linear prismatic lens.
• Tension screws secure ends to body.
• Fits flush to face of slot grid (T) ceiling types.
• Lamp shield opens from either side.
• 95% reflective specular aluminum reflector.
• Ballast accessible from room side.
• 2 earthquake clips standard.
• Can be continuous row mounted.
• Wiring access plate standard.
• Optional DALI ballast i GEN TECHNOLOGY accepts digital dimming controllers, scene controllers and automatic control devices.
• Construction to meet NYC Code or Chicago Plenum available.
Mounting Methods Dimensions
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
11/06
HP90 Recessed Fluorescent H9S1GLR254 or 154
Page 1 of 2 Direct/Indirect – 1' x 4' with Acrylic Linear Prismatic Lens
Static, 1 or 2 Lamp T5
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 5/Folio M32-21
exposed t-grid ceiling
exposed slot t-grid ceiling
Acoustical material by others
Exposed T-bar by others
1-1/2" max.
Acoustical material by others
15/16"
24"
1-7/8" max.
Exposed T-bar by others
9/16"
24"
2 earthquake clips standard
7/8" Dia. K.O.
2-1/4"
(57mm)
1-1/2" x 1-1/2"
Access Plate
With 7/8" dia. K.O.
2-1/4"
(57mm)
48" (1219mm)
fully enclosed lamp compartment
5"
(127mm)
12" (305mm)
5" (127mm)
HP90 Recessed Fluorescent H9S1GLR254 or 154
Page 2 of 2 Direct/Indirect – 1' x 4' with Acrylic Linear Prismatic Lens
Static, 1 or 2 Lamp T5
Job Information Type:
Ordering Information
Explanation of Catalog Number. Example: H9S1GLR154UNVPGGLR
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK91X4. Electrical Wiring Options: Consult factory. Optional motion or light sensor: Request Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 54W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .83. To reduce glare the average brightness at 65° shall not exceed 2500 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 70.2%.
Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat
white acrylic enamel. Reflector – low iridescence specular aluminum 95% reflectance. Phosphate undercoating.
Specifications (continued)
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Options:
Add appropriate suffix to catalog
no., ie: (GLR)
HP90
Direct/Indirect
Recessed
S
Body Style:
S = Static
1
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens
54
Lamp:
(By Others) 54=T5 54W
(Nominal 48")
R
Reflector:
Specular
Aluminum
Lamp
Quantity 1=1 Lamp 2=2 Lamp
Ballast Type:
<20THD <10THD
1 Lamp Elec. T5 HO PG ††
(54 Watt)
2 Lamp Elec. T5 HO PG ††
(54 Watt)
††Program Rapid Start (UNV only)
0.0 45.0 90.0 FLUX
0 2472 2472 2472
5 2443 2467 2491 236
15 2358 2452 2533 693
25 2189 2362 2406 1073
35 1936 2082 2071 1282
45 1601 1662 1641 1272
55 1180 1203 1188 1071
65 716 746 766 748
75 324 375 377 394
85 63 78 74 90
90 15 15 15
Model No. H9S1GLR154UNVPG
LER = FP - 56.9 IW - 61.0 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $4.21
Report Number: G2006142 Catalog Number: H9S1GLR154UNVPG Lamps: F54 T5 HO Luminaire: HP90 1' x 4' with linear
prismatic lens. Ballast: Advance ICN-2S54-90C Report is based on 4400 Lumens per lamp. Efficiency: 79.1%
CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.760 11.760
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 6941. 7205. 7114. 55 6307. 6430. 6349. 65 5194. 5411. 5556. 75 3838. 4442. 4465. 85 2216. 2743. 2603.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01858278777472747270 02787266676360656259 03716357605551575350 04655649534843514743 05605043484238464137 06554538433733423733 07514134393429383329 08483831363026353026 09453428332824322724
10 42 32 26 31 25 21 30 25 21
ZONE LUMENS % LAMP % FIXT
00-030 2002 22.7 29.2 00-040 3283 37.3 47.9 00-060 5626 63.9 82.0 00-090 6858 77.9 100.0
90-180 0000 0.0 000.0
00-180 6858 77.9 100.0
ZONAL LUMEN SUMMARY
Model No. H9S1GLR254UNVPG
LER = FP - 62.9 IW - 109.0 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $3.82
Report Number: G2006165 Catalog Number: H9S1GLR254UNVPG Lamps: F28 T5 HO Luminaire: HP90 1' x 4' with linear
prismatic lens. Ballast: B254I UNV-E Report is based on 4400 Lumens per lamp.
Efficiency: 77.9% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.800 10.800
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 5/Folio M32-21
Voltage:
120, 277 or
UNV=120-277
H9
Standard HP90
HY
For NYC Code – I.B.E.W. Manufactured
HN
For NYC Code – Local 3 Manufactured
0.0 45.0 90.0 FLUX
0 1303 1303 1303
5 1288 1304 1319 124
15 1249 1286 1305 363
25 1175 1202 1207 552
35 1059 1036 1023 649
45 880 819 850 647
55 633 609 632 548
65 365 369 383 373
75 160 179 178 189
85 29 31 28 37
90 222
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 3483. 3195. 3316. 55 3044. 2929. 3040. 65 2383. 2408. 2500. 75 1705. 1908. 1897. 85 918. 981. 886.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01878380787673757371 02797368696561666360 03726458615652595451 04665751544944524844 05615144494339474238 06574639443834433834 07524235403430393430 08493832373127363127 09463529342834332824
10 43 33 26 31 26 22 31 26 22
ZONE LUMENS % LAMP % FIXT
00-030 1039 23.6 29.8 00-040 1688 38.4 48.5 00-060 2883 65.5 82.8 00-090 3481 79.1 100.0
90-180 0000 0.0 000.0
00-180 3481 79.1 100.0
ZONAL LUMEN SUMMARY