HP90 Recessed Fluorescent H9S1GLR132 or 232
Page 1 of 2 Direct/Indirect – 1' x 4' with Acrylic Linear Prismatic Lens
Static, 1 or 2 Lamp T8
Features
• 78.8% efficient (2 lamp, 28W T8).
• 76.7% efficient (1 lamp, 28W T8).
• Direct/indirect appearance with soft contoured interior.
• Lens encloses lamp compartment.
• Translucent DR acrylic linear prismatic lens.
• Tension screws secure ends to body.
•
Same fixture fits both G and T ceiling types.
• Fits flush to face of slot grid (T) ceiling types.
• Lamp shield opens from either side.
• 95% reflective specular aluminum reflector.
• Ballast accessible from room side.
• 2 earthquake clips standard.
• Can be continuous row mounted.
• Wiring access plate standard.
• Optional DALI ballast iGEN TECHNOLOGY accepts digital dimming
controllers, scene controllers and automatic control devices.
• Construction to meet NYC Code or Chicago Plenum available.
Mounting Methods Dimensions
Exposed T-bar
by o hers
1-1/2"
max.
Acoustical
material
by o hers
15/16" *
24"
exposed t-grid ceiling
* For flushmounting when using 9/16" ExposedT-Grid
ceiling system consultfactory
2 earthquake standards
Exposed T-bar
by others
1-7/8"
max.
24"
exposed slot t-grid ceiling
fully enclosed lamp compartment
9/16"
Acoustical
material
by others
5" (127mm)
12" (305mm)
1-9/16" x 2-13/16"
Access Plate
Wi h 2-7/8" dia. K O.
2-1/4"
(57mm)
48" (1219mm)
Job Information Type:
Job Name:
Cat. No.:
5"
(127mm)
2-1/4"
(57mm)
10/07
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 a Genlyte company
Section 5/Folio M32-19
HP90 Recessed Fluorescent H9S1GLR132 or 232
Page 2 of 2 Direct/Indirect – 1' x 4' with Acrylic Linear Prismatic Lens
Static, 1 or 2 Lamp T8
Model No. H9S1GLR132UNVHI
LER = FP - 86.4 IW - 21.3 BF - 0.88
Comparative yearly lighting ene gy cost per
1000 lumens = $2.78
Report Number: G2007129
Catalog Number: H9S1GLR132UNVHI
Lamps: (1) F28 T8
Luminaire: HP90 1' x 4' with linear
prismatic lens.
Ballast: QTP1X32T8-UNV-PSX-TC
Report is based on 2725 Lumens per lamp.
Efficiency: 76.7%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.4
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 47.040 11.040
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1 84 80 77 75 73 70 72 70 68
2 76 70 65 66 62 58 63 60 57
3 69 61 55 58 53 49 56 51 48
4 63 54 47 51 46 41 49 45 41
5 58 48 41 46 40 36 44 39 35
6 54 43 36 41 35 31 40 35 31
7 50 39 32 37 32 27 36 31 27
8 46 36 29 34 28 24 33 28 24
9 43 33 26 31 26 22 30 25 22
10 40 30 24 29 24 20 28 23 20
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1793. 2194. 2494.
55 1613. 2237. 2434.
65 1355. 2040. 1913.
75 1014. 1499. 1210.
85 616. 822. 753.
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 693 693 693
5 685 690 696 66
15 657 674 689 191
25 603 639 673 295
35 525 587 644 367
45 425 520 591 396
55 310 430 468 365
65 192 289 271 260
75 88 130 105 124
85 18 24 22 27
90 333
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
0- 30 551 20 2 26.4
0- 40 919 33 7 44.0
0- 60 1679 61 6 80.4
0- 90 2090 76 7 100.0
90-180 0 0 0 0.0
0-180 2090 76 7 100.0
Model No. H9S1GLR232UNVHI
LER = FP - 75.1 IW - 50.3 BF - 0.88
Comparative yearly lighting ene gy cost per
1000 lumens = $3.19
Report Number: G2007128
Catalog Number: H9S1GLR232UNVHI
Lamps: (2) F28T8
Luminaire: HP90 1' x 4' with linear
prismatic lens.
Ballast: QTP2X32T8/UNV-ISN-SC
Report is based on 2725 Lumens per lamp.
Efficiency: 78.8%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.3
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 47.040 11.040
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1 86 82 79 77 75 72 74 72 70
2 78 72 67 68 63 60 65 62 59
3 71 63 57 59 54 50 57 53 49
4 65 56 49 53 47 43 51 46 42
5 60 50 43 47 41 37 46 41 37
6 55 45 38 43 37 32 41 36 32
7 51 41 34 39 33 29 38 32 28
8 48 37 30 35 30 25 34 29 25
9 45 34 28 33 27 23 32 27 23
10 42 31 25 30 25 21 29 24 21
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 3873. 4405. 4806.
55 3496. 4338. 4604.
65 2972. 3939. 3932.
75 2271. 3066. 2640.
85 1404. 1540. 1472.
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 1506 1506 1506
5 1488 1498 1509 143
15 1427 1450 1474 410
25 1308 1355 1399 625
35 1135 1216 1294 762
45 918 1044 1139 800
55 672 834 885 720
65 421 558 557 523
75 197 266 229 259
85 41 45 43 52
90 744
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
0- 30 1178 21 6 27.4
0- 40 1940 35 6 45 2
0- 60 3461 63 5 80 6
0- 90 4295 78 8 100 0
90-180 0 0 0 0 0
0-180 4295 78 8 100 0
Ordering Information
Explanation of Catalog Number. Example: H9S1GLR232UNVHI
HP90
Direct/Indi ect
Recessed
H9
HY
HN
S
Body Style:
S = Static
Standard HP90
For NYC Code – I B.E.W. Manufactured
For NYC Code – Local 3 Manufactu ed
1
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Ac ylic Lens
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF.
Drywall Kit: Order Catalog Number: FK91X4.
Electrical Wiring Options: Consult factory.
For motion or light sensor: See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 28W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .80. To reduce glare the average brightness at 65° shall not exceed
1913 candelas per square meter. To control veiling reflections, luminaire output
in the 30°-90° zone shall not be less than 73.6%.
Materials: Chassis parts are die-formed code gauge steel.
Lamp Shield: Linear prismatic translucent DR acrylic lens.
Finish: Chassis exterior – baked white polyester enamel. Cavity – baked
white polyester enamel. Rust preventative undercoating. Reflector – low iridescence specular aluminum 95% reflectance.
R
Reflector:
Specular
Aluminum
Lamp
Quantity
1=1 Lamp
2=2 Lamp
32
Lamp:
(By Others)
32=T8 32W *
(Nominal 48")
* 28W T8 available
Voltage:
120, 277 or
UNV=120-277
Ballast Type:
1 or 2 Lamp Elec. T8 SO * H
LOL Dimming T8 PS –
*Instant Start Standard
Other dimming options. Consult factory.
NOTE: For T8 UNV, you must use H
Code.
<20THD <10THD
Specifications (continued)
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with
Disposal Laws. See: www.lamprecycle.org
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 a Genlyte company
Section 5/Folio M32-19
Options:
Add appropriate
suffix to catalog
no., ie: (GLR)
I *
I
Ballast