Lightolier H9S1GLR228, H9S1GLR128UNVPG, H9S1GLR228UNVPG Specification

Features
• 88.9% efficient (2 lamp, 28W).
• 86.9% efficient (1 lamp, 28W).
Direct/indirect appearance with soft contoured interior.
• Lens encloses lamp compartment.
• Translucent DR acrylic high light transmission linear prismatic lens.
• Tension screws secure ends to body.
• Fits flush to face of slot grid (T) ceiling types.
• Lamp shield opens from either side.
• 95% reflective specular aluminum reflector.
• Ballast accessible from room side.
Built-in earthquake clips.
• Can be continuous row mounted.
• Wiring access plate standard.
• Optional DALI ballast i GEN TECHNOLOGY accepts digital dimming controllers, scene controllers and automatic control devices.
• Construction to meet NYC Code or Chicago Plenum available.
Mounting Methods Dimensions
HP90 Recessed Fluorescent H9S1GLR228 or 128
Page 1 of 2 Direct/Indirect – 1' x 4' with Acrylic Linear Prismatic Lens
Static, 1 or 2 Lamp T5
exposed slot t-grid ceiling
Acoustical material by others
1-7/8" max.
Exposed T-bar by others
9/16"
12"
7/8" Dia. K.O.
2-1/4"
(57mm)
2" x 2-1/2" Access Plate
With (2) 7/8" dia. K.O.
2-1/4"
(57mm)
48" (1219mm)
5"
(127mm)
12" (305mm)
fully enclosed lamp compartment
5" (127mm)
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 12/10 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © Philips Group
Section 5/Folio M32-20 Rev. A
built-in earthquake clips
exposed t-grid ceiling
Exposed T-bar by others
1-1/2" max.
Acoustical material by others
15/16" *
12"
* For flush mounting when using 9/16"Exposed T-Grid
ceiling system consult factory
HP90 Recessed Fluorescent H9S1GLR228 or 128
Page 2 of 2 Direct/Indirect – 1' x 4' with Acrylic Linear Prismatic Lens
Static, 1 or 2 Lamp T5
odel No. H9S1GLR128UNVPG
M
LER = FP - 72.1 IW - 32.6 BF - 1.04 Comparative yearly lighting energy cost per
1000 lumens = $3.33
Report Number: G2010229
atalog Number: H9S1GLR128UNVPG
C Lamps: F28T5
uminaire: HP90 1' x 4' with linear
L
prismatic lens.
allast: ICN-2S28
B
eport is based on 2600 Lumens per lamp.
R Efficiency: 86.9% CIE Type-Direct-Indirect
lane: 0-Deg 90-Deg
P Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg
uminous Length: 47.040 11.040
L
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 94 90 86 84 82 79 81 79 77 02 86 78 72 73 69 65 71 67 63 03 78 68 61 64 59 54 62 57 53 04 71 60 53 57 51 46 55 49 45 05 65 54 46 51 44 39 49 43 39 06 60 48 40 46 39 34 44 38 34 07 56 44 36 42 35 30 40 34 30 08 52 40 32 38 31 27 37 31 27 09 48 36 29 35 28 24 34 28 24
10 45 33 27 32 26 22 31 26 22
0
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 717 717 717
709 716 721 68
5
15 683 702 721 199
5 630 671 707 309
2
35 554 617 667 385
45 459 541 599 413
55 350 450 490 387
65 236 323 322 297
75 124 164 140 160
85 30 36 36 41
90 000
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
0-030 576 22.2 25.5
0 00-040 961 37.0 42.5 00-060 1761 67.7 77.9 00-090 2260 86.9 100.0
90-180 0000 0.0 000.0
00-180 2260 86.9 100.0
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
N DEG. 0-DEG. 45-DEG. 90-DEG.
I
45 1963. 2314. 2562. 55 1845. 2373. 2583. 65 1689. 2311. 2304. 75 1449. 1916. 1636. 85 1041. 1249. 1249.
Model No. H9S1GLR228UNVPG
ER = FP - 77.2 IW - 63.31 BF - 1.0
L Comparative yearly lighting energy cost per
1000 lumens = $3.11
eport Number: G2006140
R Catalog Number: H9S1GLR228UNVPG
amps: F28T5
L Luminaire: HP90 1' x 4' with linear
rismatic lens.
p Ballast: QTP2X28T5/UNV Report is based on 2750 Lumens per lamp.
fficiency: 88.9%
E CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90
lane: 0-Deg 90-Deg
P Luminous Length: 47.040 11.040
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 97 93 89 87 85 82 84 82 80 02 89 81 75 77 72 68 74 70 67 03 81 72 64 68 62 57 65 60 56 04 74 63 56 60 54 49 58 53 48 05 68 57 49 54 47 42 52 46 42 06 63 51 43 49 42 37 47 41 37 07 58 46 38 44 37 33 43 37 32 08 54 42 35 40 34 29 39 33 29 09 51 39 31 37 31 26 36 30 26
10 47 36 29 34 28 24 33 28 24
0
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 1661 1661 1661
1643 1659 1678 158
5
15 1581 1654 1725 468
5 1466 1621 1692 737
2
35 1303 1470 1512 902
45 1088 1217 1236 922
55 823 913 889 793
65 537 590 558 569
75 256 283 250 291
85 38 42 38 50
90 343
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 1364 24.8 27.9
0-040 2266 41.2 46.3
0 00-060 3981 72.4 81.4 00-090 4891 88.9 100.0
90-180 0000 0.0 000.0
00-180 4891 88.9 100.0
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
N DEG. 0-DEG. 45-DEG. 90-DEG.
I
45 4245. 4748. 4822. 55 3958. 4391. 4276. 65 3505. 3851. 3542. 75 2729. 3046. 2665. 85 1203. 1329. 1203.
0
Ordering Information
Explanation of Catalog Number. Example: H9S1GLR228UNVPG
R
Reflector:
Specular
Aluminum
HP90
Direct/Indirect
Recessed
H9
HY
S
Body Style:
S = Static
Standard HP90
For NYC Code – I.B.E.W. Manufactured
1
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C. Drywall Kit: Order Catalog Number: FK91X4. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 28W luminaires in a room cavity ratio of 1,
with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .93. To reduce glare the average brightness at 65° shall not exceed 3851 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 72.1%.
Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – baked white acrylic enamel.
28
Lamp
Quantity 1=1 Lamp 2=2 Lamp
Specifications (continued)
Cavity – baked flat white acrylic enamel. Rust preventative undercoating. Reflector –
low iridescence specular aluminum 95% reflectance. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Job Information Type:
Lamp:
(By Others) 28=T5 28W
(Nominal 48")
Voltage:
120, 277 or
UNV=120-277
Ballast Type:
1 or 2 Lamp Elec. T5 PG †
(28 Watt)
1 or 2 Lamp Elec. T5 PG ††
(28 Watt)
2-Lamp Elec. T5 VY**
(28 Watt) .95/.35 Bilevel
Step Ballast
†Instant Start (120, 277 or UNV)
††Program Rapid Start (UNV only) **.35 20THD
**.95 10THD
Add appropriate suffix
to catalog no., ie: (A)
<10THD
Options:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 12/10 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © Philips Group
Section 5/Folio M32-20 Rev. A
Loading...