GUARDSMAN GV4WA232
Page 1 of 2 Vandal Resistant Wraparound, 10-5/16" WIDE, 4' OR 8' LENGTH
SURFACE FLUORESCENT 2 LAMP, T8 OR T12
DIMENSIONS
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 6A/Folio P20-60
Features
• Excellent for locations where vandal resistance is required.
• Prismatic lens is 50% DR (impact resistant), and 50% standard acrylic with a nominal thickness of 1/8", withstands 70 ft. lbs. impact without breaking.
• Tamper resistant holt head screws secure lens to housing.
• UL-Listed for direct mounting on low density ceilings and damp locations.
• Steel end caps, standard.
• Self-aligning for continuous row mounting.
• Heavy duty, die formed channel of code gauge steel.
48" (1219 mm)
11/16" Dia. K.O. (2)
7/8" Dia. K.O. (3)
4' FIXTURE
1/4" x 1/2" K.O. (2)
2-1/4" (57mm) 3-1/4" (83mm) 4-1/4" (108mm)
96" (2438 mm)
13/16" (21mm)
24" (610mm) 24" (610mm)
8' FIXTURE
1/4" x 1/2" K.O. (2)
7/8" Dia. K.O. (4)
11/16" Dia. K.O. (4)
2-1/4" (57mm) 3-1/4" (83mm) 4-1/4" (108mm)
2-7/8"
(73mm)
10-5/16" (262mm)
C
L
C
L
11/16" (17mm)
GUARDSMAN GV4WA232
Page 2 of 2 Vandal Resistant Wraparound, 10-5/16" WIDE, 4' OR 8' LENGTH
SURFACE FLUORESCENT 2 LAMP, T8 OR T12
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 6A/Folio P20-60
Job Information Type:
OPTIONS & ACCESSORIES
SCREWDRIVER: For holt head screw. Order Catalog Number LP156737. ELECTRICAL/WIRING OPTIONS Consult factory FUSING: Internal fast-blow fusing.
SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF.
SPECIFICATIONS
PERFORMANCE: In an installation of 2 lamp 32W luminaires in a room cavity
ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .79. To reduce glare the VCP shall be not less than 45 either cross­wise or lengthwise (at 100fc level) and the average brightness at 65° shall not exceed 2273 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 73.4%. MATERIALS: Chassis parts are die formed code gauge cold rolled steel. FINISH: Multi-stage phosphate treated for maximum corrosion resistance and finish coat high reflectance baked white enamel.
SPECIFICATIONS (continued)
LENS: Prismatic lens is 50% DR (impact resistant) and 50% standard acrylic
with a nominal thickness of 1/8", withstands 70 ft. lbs. impact without breaking.
SCREWS: Tamper resistant holt head screws secure lens to housing. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB.
If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.
MODEL NO. GV4WA232120SO
ORDERING INFORMATION
Explanation of Catalog Number. Example: GV4WA232120SOGLR
Other dimming options. Consult factory.
LER = FW - 70 IW - 59 BF - 0.92 Comparative yearly lighting energy cost per 1000 lumens = $3.43
GV
GUARDSMAN
VANDAL
RESISTANT
FIXTURE LENGTH:
4=4 Foot 8=8 Foot
WA
FIXTURE
TYPE:
WA=Wraparound
10-5/16" wide
2
LAMP
QUANTITY
LAMP TYPE/
FIXTURE LENGTH:
32=T8 34=T12
(nominal 48"
or 96")
VOLTAGE:
120 or 277
BALLAST TYPE:
2 Lamp Mag. T12 LE
20THD 10THD
2 Lamp Elec. T8 SO* H
I*
*Instant Start Standard
OPTIONS:
Add appropriate suffix to catalog
no, ie: (GLR)
coefficient of utilization pfc 20
pcc 80 70 50
pw 70 50 30 70 50 30 50 30
RCR
0919191 888888 8181
1827976 807773 7169 27669657268636459 36861566759545652
46455476153465145 55848425647514540 65444385242364035
75040344839333832 84636294535293428 94434284133273226
10 40 30 25 40 29 25 28 23
typical V.C.P.’s
Room Mounting Height
Size Lengthwise Crosswise
8.5 10 8.5 10
30x30 61 64 57 62 40x40 58 61 51 56 60x30 62 66 60 65 60x60 55 57 45 50
100x100
53 54 40 43
candlepower
angle end 45 cross
0 1482 1482 1482
5 1482 1482 1479 15 1432 1463 1483 25 1331 1409 1458 35 1186 1313 1375 45 967 1078 1045 55 541 615 568 65 305 329 388 75 162 208 292 85 45 129 251 95 0 111 261
105 1 147 199 115 3 83 107 125 44862 135 64457 145 73447 155 72132 165 5915 175 567
Loading...