Lightolier FRS2GFW2FT User Manual

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 a Philips Group Section 5/Folio MA10-12
Lightolier is a Philips group brand
11/08
Job Information Type:
Cat. No.:
Lamp(s):
Volts/Ballast:
Features
• Ideal for boardrooms, entrances and other spaces seeking a clean architectural look.
• Frost White DR acrylic lens.
• Can be mounted in patterns, end to end or side to side.
• Blends in with regular flat-edge and aesthetic recessed-edge ceiling tiles.
• 74.0% efficient (2 Lamp 25 watt TT5)
• 63.5% efficient (2 Lamp 40 watt TT5)
• 5" deep body.
• One piece housing.
• Black exterior for cooler ballast operating temperature.
• Built-in earthquake clips (patent no. 5,072,344).
• Spring loaded latches/hinge.
• Lens encloses lamp compartment.
• Lens opens from either side.
• Ballast accessible from room side.
• Wiring access plate standard.
• Construction to meet NYC Code or Chicago Plenum available.
FRX Series FRS2GFW2FT
Page 1 of 2 Architectural Recessed Fluorescent
2' x 2' with Frost White Acrylic Lens, 2 Lamp TT5
5"
(127mm)
2" X 2-1/2" Access Plate with (2) 7/8" (73mm) Dia. KO’s
24"
(610mm)
24" (610mm)
5" (127mm)
Mounting Methods Dimensions
23-7/8" (606mm) Square Lens
13/16"
(21mm)
exposed T-grid ceiling.
24"
15/16"
or
9/16"
2" max.
hold-down clips
Tegular grid ceiling
2" max.
24"
FRX Fixture
Support (by others)
Drywall Kit (See Options)
Drywall
(by others)
Drywall Kit, Catalog Number: FK92X2.
G
G
15/16"
or
9/16"
Expample of pattern mounting
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 a Philips Group Section 5/Folio MA10-12
Job Information Type:
Lightolier is a Philips group brand
FRX Series FRS2GFW2FT
Page 2 of 2 Architectural Recessed Fluorescent
2' x 2' with Frost White Acrylic Lens, 2 Lamp TT5
Ordering Information
Explanation of Catalog Number. Example: FRS2GFW2FTUNVIB
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10 and OA20-30.
Specifications
Performance: In an installation of 2 lamp 25W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .77. To reduce glare the average brightness at 65° shall not exceed 3447 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 72.0%.
Lamp Shield: Frost white DR acrylic lens. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing
is ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling. Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Rust preventative undercoating.
Specifications (continuned)
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Options:
Add appropriate suffix to catalog
no., ie: (A)
FRX
Architectural
Recessed
Fluorescent
S
Body Style:
S = Static
2
Fixture
Width
G
Ceiling Type:
G = Standard
Grid
F
Lens:
F= Frost White
Acrylic Lens
FT
Lamp:
(By Others)
FT = Twin Tube T5
W
Reflector:
White
2
Lamp
Quantity 2=2 Lamp
Ballast Type:
<20THD <10THD
2 Lamp Elec. TT5 SB* IB**
(25 or 40 Watt)
2 Lamp Elec. TT5 PR†
(40 Watt)
2 Lamp Elec. TT5 BE*
(50 Watt)
2 Lamp Elec. TT5 –BF*
(55 Watt)
LOL Dimming TT5 PB *Instant Start Standard. Other dimming options. Consult factory.
NOTE:
For TT5 40W UNV, you must use PR Ballast Code. †Program Rapid Start
0.0 45.0 90.0 FLUX
0 1421 1421 1421
5 1407 1406 1407 134 15 1341 1339 1339 378 25 1241 1227 1227 566 35 1084 1078 1074 675 45 903 897 888 692 55 697 693 676 616 65 469 470 444 458 75 236 244 212 251 85 68 70 48 79 90 52 52 31
Model No. FRS2GFW2FTUNVIB (25 watt lamp)
LER = FP - 59.1 IW - 59.9 BF - 0.92 Comparative yearly lighting energy cost per
1000 lumens = $4.06
Report Number: G2008273 Catalog Number: FRS2GFW2FTUNVIB Lamps: (2) PL-L40/835/XEW/4P/RS/IS 25W Luminaire: FRX Arch itectural Recessed
2' x 2' fixture with acrylic lens. Ballast: ICN-2TTP40-SC Report is based on 2600 Lumens per lamp.
Efficiency: 74.0% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 4104. 4077. 4036. 55 3852. 3830. 3736. 65 3440. 3447. 3256. 75 2693. 2784. 2419. 85 1876. 1931. 1324.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01817774727068696766 02736762635956615755 03675953565147545046 04615246494440484339 05564740443935433834 06524236403530383430 07483832363127393027 08453529332824352824 09423226312522322522
10 39 30 24 28 23 20 28 23 20
ZONE LUMENS % LAMP % FIXT
00-030 1078 20.7 28.0 00-040 1753 33.7 45.5 00-060 3061 58.9 79.5 00-090 3849 74.0 100.0
90-180 0000 0.0 000.0
00-180 3849 74.0 100.0
ZONAL LUMEN SUMMARY
Voltage:
120, 277 or
UNV=120-277
0.0 45.0 90.0 FLUX
0 1512 1512 1512
5 1500 1499 1500 143 15 1434 1432 1433 405 25 1322 1318 1318 608 35 1169 1162 1159 728 45 980 971 963 750 55 764 756 737 673 65 523 519 490 507 75 275 279 242 287 85 83 85 62 93 90 55 56 33
Model No. FRS2GFW2FTUNVIB (40 watt lamp)
LER = FP - 55.5 IW - 69.5 BF - 0.92 Comparative yearly lighting energy cost per
1000 lumens = $4.26
Report Number: G2008272 Catalog Number: FRS2GFW2FTUNVIB Lamps: (2) PL-L40/835/RS/IS Luminaire: FRX Arch itectural Recessed
2' x 2' fixture with acrylic lens. Ballast: ICN-2TTP40-SC Report is based on 3300 Lumens per lamp.
Efficiency: 63.5% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 4454. 4413. 4377. 55 4223. 4178. 4073. 65 3836. 3806. 3594. 75 3138. 3184. 2762. 85 2290. 2345. 1711.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01696663626058595856 02635753545148524947 03575045484340464239 04524539423834413734 05484034383329373229 06443630342926332926 07413337312623302623 08383024282420282320 09362622262218262118
10 34 25 20 24 20 17 24 20 17
ZONE LUMENS % LAMP % FIXT
00-030 1155 17.5 27.6 00-040 1883 28.5 44.9 00-060 3306 50.1 78.8 00-090 4194 63.5 100.0
90-180 00000.0000.0
00-180 4194 63.5 100.0
ZONAL LUMEN SUMMARY
FR
Standard FRX
FY
For NYC Code – I.B.E.W. Manufactured
FN
For NYC Code – Local 3 Manufactured