7/8"
[ 22mm] Knockout (x2)
10
9
4
3
2
1
5
7
8
6 7/8"
[175mm]
6 7/8"
[175mm]
8"
[203mm]
8 7/16"
[214mm]
6
11
23 3/8"
[594mm]
4 3/16"
[107mm]
3 5/8"
[92mm]
4 1/8"
[104mm]
3 1/4"
[82mm]
18"
[458mm]
Backplate Detail
1 1/2" [38mm]
Brisa
Linear Curve Surface Mount FC14U
Page 1 of 2 Wall/Ceiling Mounted T5 Fluorescent ADA Compliant
Fixture Ordering Information
Catalog No. Description Finish Wattage Volts Lamp
FC14U
Diffuser Ordering Information
Linear Curve Surface Mount Satin aluminum 14W 120V-277V (1) T5
Catalog No. Description Finish
FCA1
FCG1
Acrylic Curve Diffuser Opal 4" X 24"
Glass Cur ve Diffuser Cased Opal (Sandblasted Outside Surface) 4" X 24"
Features
1. Diffuser Holder: (2) Die-cast aluminum. One stationary and one spring
loaded for ease of diffuser removal and lamping.
2. Lamp Housing: Extruded aluminum.
3. Ballast Housing: (2) Die-cast aluminum.
5. Junction Box Mounting Plate: 18ga. C.R.S zinc plated. For mounting
to standard 4” octagonal junction box. Not required for conduit mounted
installations.
6. Backplate: 18ga. C.R.S. zinc plated. Provided with (2) 7/8” diameter
conduit knockouts (for non junction box installation) and (2) 3/16” diameter
mounting holes for direct mounting to wall or ceiling surface (hardware not
provided).
7. Luminaire Ballast Disconnect: Meets NEC 410.130 (G) and CEC
disconnect requirements
8. Lampholder: Fluorescent- Mini Bi-Pin, G5 Base
9. Junction Box Cover: (2) Die-cast aluminum, easy installation (provided
with luminaire). Not required for conduit mounted installation.
10. Diffuser: Either 3mm cur ved opal acrylic or opal glass.
Electrical
11. Ballast (Electronic 120 -277V)
Voltage 120V 277V
Total Input Watts 18W 18W
Max. Line Current (Amps) 0.15A 0.07A
Power Factor 0.98 0.90
THD <10% <15%
Min. Starting Temp 0°F, -18°C 0°F, -18°C
Lightolier is a Philips group brand
Dimensions
(Nominal)
Lamping (by others)
General Electric Osram/Sylvania Philips
(1) 14W T5 Linear Fluorescent
F14W/T5/*/ECO FP14/* F14T5/*/ALTO
*Manufactures Color Temperature Designation
Finish
Satin Aluminum
Labels
cULus Listed. Suitable for Damp Locations.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • C0408
™
50
100
150
200
0°
30°
60°
90°
Brisa
Linear Curve Surface Mount FC14U
Page 2 of 2 Wall/Ceiling Mounted T5 Fluorescent ADA Compliant
FC14U/FCA1
DECOR ATIVE LUMINAI RE CAT. # FC14U/FCA1 14W PHILIPS T- 5
LAMP S. LUMEN RATING = 120 0 LMS. BALL AST/ UNIVERSAL # B228PUNV -C
Cand lepower Su mmary
Angle A long 22.5 . 45 67.5 Acro ss.
0 182 182 182 182 182
5 18 2 182 18 2 182 182 17
15 176 176 177 177 177 50
25 164 165 166 166 166 77
35 147 148 149 150 150 93
45 125 126 127 129 129 9 8
55 98 100 10 2 104 105 91
65 69 70 74 78 80 74
75 36 39 47 54 57 5 0
85 8 15 2 6 34 38 30
9 0 2 12 26 37 42
9 5 5 13 3 6 51 58 33
105 21 14 24 3 9 47 30
27 22 28 31 34 28
125 27 33 33 37 39 3 0
135 26 3 3 37 4 0 42 28
145 25 28 41 43 43 23
155 25 25 33 41 42 15
165 21 21 24 31 35 7
175 25 23 20 15 13 2
180 20 20 20 20 20
Outpu t
Lumens
Ceiling 80% 70% 50% 30% 10%
Wall 70 50 30 10 70 50 30 10 50 30 10 5 0 30 10 5 0 30 10 0
RCR Zonal Cavit y Method - Ef fectiv e Floor Refle ctance = 20%
0 .73 .73 .73 .73 .70 .70 .70 .70 . 63 .63 .63 .57 .57 .57 .51 .51 .51 .48
1 . 67 .63 . 61 .58 . 63 .60 .58 . 56 . 55 . 53 .51 . 49 .48 .47 . 45 .43 .42 .40
2 .60 .55 .51 .47 . 57 .53 .49 . 45 .48 .45 .42 . 43 .41 . 39 .39 .37 .35 .33
3 .55 .49 .44 . 40 .52 .46 .42 .3 8 .42 .3 8 .35 .3 8 .35 .3 3 .35 .32 . 30 .28
4 .50 .43 .38 . 33 .48 .41 .36 .3 2 .37 .3 3 .30 .3 4 .31 . 28 .31 .28 . 26 .24
5 .46 .38 .32 . 28 .43 .36 .31 .2 7 .33 .2 9 .26 .3 0 .26 . 24 .27 .24 . 22 .20
6 .42 .34 .28 .24 . 40 .32 .27 . 23 .30 . 25 .22 . 27 .23 .21 . 25 .21 .19 .17
7 .39 .30 .25 . 21 .37 .29 .24 .2 0 .27 .2 2 .19 . 24 .21 .18 .2 2 .19 .17 .15
8 .36 .27 .22 .18 . 34 .26 .21 .18 .24 . 20 .17 . 22 .18 .15 . 20 .17 .14 .13
Room C avity Rat io
9 .33 .25 .19 .16 . 31 .24 .19 .15 . 22 .17 .14 . 20 .16 .13 .18 .15 .12 .11
10 .31 .22 .17 .14 . 29 .21 .17 .13 . 20 .15 .13 .18 .14 .12 .16 .13 .11 .10
Deter mined In Acc ordance Wi th Current I ES Published Pr ocedures
Zona l Lumens an d Percent ages
Zone Lumen s % Lamp %Lumina ire
0-3 0 143 11.98 18.51
0-4 0 2 37 19.76 30.5 3
0-6 0 42 6 3 5.56 54.93
0-9 0 5 79 4 8.31 74.63
40- 90 3 42 2 8.55 44.10
60- 90 15 3 12.75 19.70
90-180 197 16 .43 25.37
0-180 776 64.74 100.0 0
** Effic iency = 64.7% **
TESTED A CCORDING TO IE S PROCEDUR ES. TEST DISTANC E EXCEEDS FIVE
TIMES T HE GREATEST LUM INOUS OPENI NG OF LUMINAI RE.
Coef ficient s of Utiliz ation
Luminai re Input Wat ts = 20.0
Cert ified Test Repo rt no.362 9FR
Compu ted by LSI Pr ogram **TEST- LITE**
SC = 1.3
Prep ared For:
Light olier
Fall River, MA
Lightolier is a Philips group brand
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • C0408