FBP Series Fluorescent Emergency Ballast FBP90
Page 1 of 1 One Lamp Operation 600 Lumens
The FBP Series quickly converts standard fluorescent luminaires into emergency luminaires.
9.4”
(23.9 cm)
Nickel Cadmium Battery
Complete Fixture consists of ballast unit. Select options and accessories below.
2.4”
(6.1 cm)
Model # Max. Lumens Lamp Operation
FBP90 600 One
1.5”
(3.8 cm)
Features
1. Lamp Operation: Operates the following lamp types: T8 linear fluorescent,
T12 linear fluorescent, T9 circline, T12 U-bent, T5 long compact fluorescent.
See Lamp Operation and Per formance table for specific lamp performance
and operation.
2. Illumination: Provides 90 minutes of emergency illumination, and produces
500-600 lumens initial emergency light output. Can be used with most 17w
to 40w (2’ - 4’) T8, T10 or T12 fluorescent lamps without integral starters
including U-shaped, HO, VHO, circline, energy saving, and 4 pin compacts. It
is also compatible with most 1, 2, 3 and 4-lamp electronic, standard, energy
saving and dimming AC ballasts.
3. Housing: Constructed of 20 gauge steel with a white high temperature powder coat paint finish. Slim housing allows for wireway channel mounting on
most recessed luminaires.
4. Electronics: 120/277 VAC dual voltage input with surge-protected, solidstate circuitry. Charging system is complete with AC indicator lamp and test
switch.
5. Battery: Maintenance free, sealed nickel cadmium battery has an estimated
service life of 10 years, and an operating temperature range of 32°F (0°C) to
131°F (55°C).
6. Input Power Requirements: 4 watts max.
7. Warranty: Electronics: 1 year; Battery: 1 year.
Code Compliance
UL 924 listed.
Options
EX = Special Input Transformer for 220 VAC/50 Hz, 240 VAC/50Hz.
Contact factor y for other input voltages and frequencies.
DL = UL Damp Location Listing
Lamp Operation and Performance
Non-Emer. Emer. Op.
Max. Max. Emer
Lamp Base Lumen Lumen Lamp
Type Watt. Type Output Output Operation
F20T12 20 G13/Med Bi-Pin 1275 500 - 600 One
F30T12 30 G13/Med Bi-Pin 2350 500 - 600 One
F40T12 40 G13/Med Bi-Pin 2650 500 - 600 One
F40T12/U 40 G13/Med Bi-Pin 3100 500 - 600 One
F48T10 110 R17D/Recessed 6200 500 - 600 One
F17T8 17 G13/Med Bi-Pin 1350 500 - 600 One
F25T8 25 G13/Med Bi-Pin 2150 500 - 600 One
F32T8 32 G13/Med Bi-Pin 2950 500 - 600 One
F32T8/U 32 G13/Med Bi-Pin 2700 500 - 600 One
F40T8 40 G13/Med Bi-Pin 3725 500 - 600 One
FC6T9 20 G10Q/4 Pin 800 500 - 600 One
FC8T9 22 G10Q/4 Pin 1100 500 - 600 One
FC12T9 32 G10Q/4 Pin 1950 500 - 600 One
FC16T9 40 G10Q/4 Pin 2700 500 - 600 One
F39/36BX 39 2G11/4 Pin 2850 500 - 600 One
F40/30BX 40 2G11/4 Pin 3150 350 - 450 One
Notes:
1. Maximu m non-emer gency lume n output c an vary ba sed on lamp manufact urer, ambient o perating
tempe rature, an d ballast ma nufactur er.
2. Maximu m emergenc y lumen out put is base d on total output of one or two lamps, and c an vary
base d on lamp manu facture r and ambien t operatin g temperat ure.
3. Maximu m emergenc y lumen out put is supp orted fo r a full 90 min utes of op eration.
4. Consult factory for compa tibility, ope ration and perform ance of lam p types n ot listed.
Accessories
CCAPS = Wire bundle cover for mounting external to luminaire
RTS = Single gang aluminum faceplate pre-drilled to accommodate remote installa-
tion of test switch and pilot light
Lightolier is a Philips group brand
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • C0308