Lightolier FBP750-4P User Manual

FBP Series Fluorescent Emergency Ballast FBP750-4P
Page 1 of 1 One or Two Lamp Operation 4-Pin Fluorescent Lamps 750 Lumens
9.4”
(23.8 cm)
1.5”
(3.8 cm)
Nickel Cadmium Battery
Complete Fixture consists of ballast unit. Select options and accessories below.
2.4”
(6.1 cm)
Model # Max. Lumens Lamp Operation
FBP750-4P 750 One or Two 4-Pin Fluorescent (without integral starter)
Features
1. Lamp Operation: Operates the following lamp types: T4 Compact Fluorescent
(4-pin base), 13W - 42W twin, quad and triple twin-tube without integral starter. See Lamp Operation and Performance table for specific lamp perfor-
mance and operation.
2. Illumination: Provides 90 minutes of emergency illumination, and produces a maximum of 750 lumens initial emergency light output.
3. Housing: Constructed of 20 gauge steel with a high temperature powder coat finish. Housing allows for frame mounting on most recessed luminaires. Housing includes 2’ lengths of flex conduit attached on each end.
4. Electronics: 120/277 VAC dual voltage input with surge-protected, solid­state circuitry. Charging system is complete with AC indicator lamp and test
switch.
5. Battery: Maintenance free, sealed nickel cadmium battery has an estimated service life of 10 years, and an operating temperature range of 32°F (0°C) to 131°F (55°C)
6. Input Power Requirements: 3.5 wat ts max.
7. Warranty: Electronics: 2 years; Battery: 2 years.
Code Compliance
UL 924 listed. UL damp location listing optional.
Lamp Operation and Performance
Non-Emer. Emer. Op. Max. Max. Emer Lamp Base Lumen Lumen Lamp Type Watt. Type Output Output Operation
F13DBX/4P 13 G24Q-1 900 425 One or Two
F18DBX/4P 18 G24Q-2 1150 575 One or Two
F26DBX/4P 26 G24Q-3 1710 700 One or Two
F18TBX/4P 18 GX24Q-2 1200 525 One or Two
F26TBX/4P 26 GX24Q-3 1800 725 One or Two
F32TBX/4P 32 GX24Q-3 2200 750 One or Two
F42TBX/T4 42 GX24Q-4P 3200 750 One
F18BX 18 2G11 4 Pin 1250 400 One or Two
F27/24BX/RS 27 2G11 4 Pin 1800 550 One or Two
F39/36BX/RS 39 2G11 4 Pin 2850 750 One or Two
F40/30BX/RS 40 2G11 4 Pin 3150 650 One
F382D/4P 38 GR10Q-4 2850 650 One or Two
Options
EX = Special Input Transformer for 220 VAC/50 Hz, 240 VAC/50Hz. Contact
factory for other input voltages and frequencies.
DL = UL Damp Location Listing
Accessories
CCAPS = Wire bundle cover for mounting external to luminaire.
RT = Remote Test Switch.
Notes:
1. Maxim um non-eme rgency lum en output can vary b ased on lam p manufac turer, ambien t operatin g tempe rature, an d ballast ma nufactur er.
2. Maxim um emergen cy lumen ou tput is bas ed on tot al output o f one or tw o lamps, and can vary base d on lamp manu facture r and ambien t operatin g temperat ure.
3. Maxim um emergen cy lumen ou tput is sup ported f or a full 90 minutes of o peration.
4. Consul t factor y for comp atibility, op eration an d perfor mance of la mp types not listed.
Lightolier is a Philips group brand