Lightolier EYS414FR354 User Manual

Mounting Methods Dimensions
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
1/06
Page 1 of 2 14 Cell Louver, 90% Downlight, 10% Uplight
48" Length 3 Lamp T5/T8, 96" Length 3 Lamp T5/T8 in Tandem
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section 5/Folio K60-20
8-15/16" (227mm)
5-3/16"
(132mm)
Features
• Energy savings replacement for HID Low or High Bay.
• Ideal for stores, schools, labs, warehouses.
• 90% downlight, 10% uplight.
• 91.9% efficient (3 lamp 54W T5). 79.3% efficient (3 lamp 32W T8).
• 1.2 spacing mounting ratio (3 lamp 54W T5).
• 1.2 spacing mounting ratio (3 lamp 32W T8).
• Can be pendant or surface mounted.
• 48" or 96" modular lengths.
• 95% reflective Specular Aluminum top Reflector.
• 20 gauge steel housing. 18 gauge steel ends.
• 22 gauge steel side reflectors.
• Flat white acrylic baked enamel, post painted.
• Louver can hinge from either side.
Louver safety chain standard.
• Removeable upper end cap for thru wiring.
• Can be stem or cable mounted at fixture joints.
• K.O. in upper end cap for occupancy sensor.
• Heavy duty coupler available.
• Meets NYC Code requirements.
can be stem mounted at fixture joints
can be cable mounted at fixture joints
can be suspended with chain hanger sets Catalog No. AH5 CSP
Luminaire-Mounted Motion Sensor
360° coverage, up to 45 ft. mounting distance. Field installed. Catalog Number: FHB360.
• Line voltage accepts 120 through 347 volt applications.
• Uses passive infrared (PIR) technology shielded by a fresnel lens; upon detection of infrared energy levels, the sensor is triggered and switches the light on.
• Light shuts off after a time delay unit that is factory preset at 10 minutes, manually adjustable from 30 sec. to 20 min. using tool included.
• Mounts on either end using 7/8" knockouts provided.
heavy duty coupler, required for continuous row mounting. Catalog No. EY COUPLER
11/16” Dia. K.O.
(2 Places)
S Hook
Slots (8)
S Hook
Slots (8)
7/8” Dia. K.O.
(2 places)
4-3/8”
(111mm)
3-1/8”
(81mm)
11/16” Dia.
K.O.
(2 Places)
48” (1220mm) 87-3/8” (2219mm) 89-3/4" (2279mm)
96" (2441mm)
39-3/8” (999mm)
41-3/4” (1059mm)
48” (1220mm)
7/8” Dia. K.O.
4-3/8”
(111mm)
3-1/8”
(81mm)
optional occupancy sensor see folio OA60-10
0.0 45.0 90.0 FLUX
0 2310 2310 2310
5 2288 2281 2301 217
15 2114 2137 2141 600
25 1853 1834 1913 859
35 1539 1558 1799 1009
45 1203 1289 1720 1060
55 825 1059 1484 978
65 439 719 1059 720
75 199 387 546 399
85 52 145 76 130
90 6 96 26
95 19 54 56 54
105 58 67 76 67
115 104 68 83 82
125 150 103 86 105
135 193 175 126 129
145 230 240 209 143
155 260 262 270 122
165 282 280 282 79
175 294 288 289 28
180 290 290 290
Page 2 of 2 14 Cell Louver, 90% Downlight, 10% Uplight
48" Length 3 Lamp T5/T8, 96" Length 3 Lamp T5/T8 in Tandem
Job Information Type:
Ordering Information
Explanation of Catalog Number. Example: EYS414FR332UNVH3
Options/Accessories
Stem and Canopy Sets: Suspends fixture 6", 12", 18" or 24" from surface. Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC 24 CSP (24"). Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF. Emergency Pack: Factory-installed emergency power battery pack with charger and inverter. SUFFIX: LP400 (T8). LP550 (T5). Cable Hangers: Adjustable 6"-60". Single Cable and Canopy: Catalog Number: WC60. Single Cable, Straight Cord and Canopy: Catalog Number: WCC60**. Single Cable, Coil Cord and Canopy: Catalog Number: WCCC60**. Chain Hanger Kits: Catalog Number: AH5 CSP.
**Cord, 3-#18 wires.
Specifications
Materials: Housing is die-formed 20 gauge cold rolled steel with full length
channel for thru wiring.
Fixture Ends: 18 gauge cold rolled steel. Louver: 22 gauge cold rolled steel. Side Reflectors: Solid 22 gauge cold rolled steel. Finish: Post painted white acrylic baked enamel.
Specifications (continued)
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
EY
Options:
Add appropriate suffix to catalog
no., ie: (GLR)
Eye-Q LB:
Suspended/
Surface
Fluorescent
Luminaire
S
S=Solid
Sides
Fixture Length:
4=48" 8=96"
R
R= 10% Uplight
Reflector
Model No. EYS414FR332UNVH3
LER = FP - 67.9 IW - 88.5 BF - 0.89 Comparative yearly lighting energy cost per
1000 lumens = $3.53
Report Number: G2005274 Catalog Number: EYS414FR332UNVH3 Lamps: F32T8/TL841 Luminaire: Eye-Q LB with solid sides, 14 cell flat white louver and 10% uplight specular reflector Ballast: B332I120RH-A Triad Report is based on 2850 Lumens per lamp. Efficiency: 79.3% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.1 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 48.000 9.000 Height of Side: 3.960 3.960
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 5637. 5184. 6059. 55 4615. 4823. 5699. 65 3166. 3911. 4624. 75 2109. 2715. 2864. 85 1101. 1497. 519.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01848077737068686664 02767065635956595653 03706255565147524845 04645548504440474239 05594942453935423733 06544437403530383329 07504033373127353026 08473630332824322723 09443327312522292421
10 41 31 24 28 23 20 27 22 19
ZONE LUMENS % LAMP % FIXT
00-030 1675 19.6 24.7 00-040 2684 31.4 39.6 00-060 4722 55.2 69.6 00-090 5971 69.8 88.1
90-120 203 2.4 3.0 90-130 308 3.6 4.5 90-150 580 6.8 8.6 90-180 808 9.5 11.99
00-180 6780 79.3 100.0
ZONAL LUMEN SUMMARY
Model No. EYS414FR354UNVPU
LER = FP - 71.5 IW - 169.8 BF - 1.00 Comparative yearly lighting energy cost per
1000 lumens = $3.36
Report Number: G2005289 Catalog Number: EYS414FR354UNVPU Lamps: FP54/835 Luminaire: Eye-Q LB with solid sides, 14 cell flat white louver and 10% uplight specular reflector. Ballast: B454IUNV-E Universal Report is based on 4400 Lumens per lamp. Efficiency: 91.9% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.1 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 48.000 9.000 Height of Side: 3.960 3.960
0.0 45.0 90.0 FLUX
0 4130 4130 4130
5 4099 4078 4120 390
15 3817 3823 3688 1067
25 3351 3216 3526 1546
35 2787 2907 3081 1801
45 2218 2268 2991 1883
55 1512 1902 2679 1759
65 809 1335 1662 1258
75 365 697 1209 774
85 93 249 139 234
90 9 162 34
95 40 92 101 92
105 137 110 122 111
115 247 60 90 115
125 358 135 56 153
135 461 257 157 217
145 552 396 295 254
155 624 502 452 239
165 675 616 573 174
175 699 686 681 65
180 695 695 695
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 10393. 9121. 10536. 55 8458. 8662. 10288. 65 5834. 7262. 7257. 75 3867. 4891. 6341. 85 1970. 2571. 949.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01979389848179797674 02898175736965696562 03817164655954615652 04746355585146544945 05685648524540494339 06635143474035443834 07584638423631403430 08544234393228373127 09513831362925342824
10 47 35 28 33 27 23 31 26 22
ZONE LUMENS % LAMP % FIXT
00-030 3003 22.7 24.8 00-040 4804 36.4 39.6 00-060 8446 64.0 69.6 00-090 10711 81.1 88.3
90-120 318 2.4 2.6 90-130 470 3.6 3.9 90-150 942 7.1 7.8 90-180 1420 10.8 11.7
00-180 12131 91.9 100.0
ZONAL LUMEN SUMMARY
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section 5/Folio K60-20
Voltage:
120, 277 or
UNV=120-277
14= 14 Cell
Louver 1 Row
42= 42 Cell
Louver 3 Rows
F
Finish: F=Flat
White
Lamp Type:
(By Others)
32=T8 28=T5 54=T5
(Nominal 48")
3
Lamp
Quantity:
3=3 Lamp
3 Lamps in
Tandem for
96" Units
Ballast Type:
<
20THD <10THD
1-2 & 1-1 Lamp Elec. T8 (4') SO * HI * 3-2 Lamp Elec. T8 (8') SO * HI * 1-3 or 2-3 Lamp Elec. T8 O3 * H3 * 1-2 & 1-1 Lamp 28W Elec. T5 (4') –PI † 3-2 Lamp 28W Elec. T5 (8') –PI † 1-3 or 2-3 Lamp 54W Elec. T5 PU †† 1-2 & 1-1 Lamp 28W or 54W Elec. T5 (4') PG †† 3-2 Lamp 28W or 54W Elec. T5 (8') PG †† LOL T8 Dimming PS *
Other dimming options. Consult factory.
*Instant Start Standard†Instant Start (120V or 277V only)
††Program Rapid Start (UNV only)
NOTE:
For T8 UNV, you must use HI, H3 Ballast Code.
Loading...