Lightolier EYS414FR254 User Manual

Mounting Methods Dimensions
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
1/06
Page 1 of 2 14 Cell Louver, 90% Downlight, 10% Uplight
48" Length 2 Lamp T5/T8, 96" Length 2 Lamp T5/T8 in Tandem
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section 5/Folio K60-15
8-15/16" (227mm)
5-3/16"
(132mm)
Features
• Energy savings replacement for HID Low or High Bay.
• Ideal for stores, schools, labs, warehouses.
• 90% downlight,10% uplight.
• 93.3% efficient (2 lamp 54W T5). 80.6% efficient (2 lamp 32W T8).
• 1.1 spacing mounting ratio (2 lamp 54W T5).
• 1.2 spacing mounting ratio (2 lamp 32W T8).
• Can be pendant or surface mounted.
• 48" or 96" modular lengths.
• 95% reflective Specular Aluminum top Reflector.
• 20 gauge steel housing. 18 gauge steel ends.
• 22 gauge steel side reflectors.
• Flat white acrylic baked enamel, post painted.
• Louver can hinge from either side.
Louver safety chain standard.
• Removeable upper end cap for thru wiring.
• Can be stem or cable mounted at fixture joints.
• K.O. in upper end cap for occupancy sensor.
• Heavy duty coupler available.
• Meets NYC Code requirements.
11/16” Dia. K.O.
(2 Places)
S Hook
Slots (8)
39-3/8” (999mm)
41-3/4” (1059mm)
48” (1220mm)
7/8” Dia. K.O.
can be stem mounted at fixture joints
can be cable mounted at fixture joints
can be suspended with chain hanger sets Catalog No. AH5 CSP
Luminaire-Mounted Motion Sensor
360° coverage, up to 45 ft. mounting distance. Field installed. Catalog Number: FHB360.
• Line voltage accepts 120 through 347 volt applications.
• Uses passive infrared (PIR) technology shielded by a fresnel lens; upon detection of infrared energy levels, the sensor is triggered and switches the light on.
• Light shuts off after a time delay unit that is factory preset at 10 minutes, manually adjustable from 30 sec. to 20 min. using tool included.
• Mounts on either end using 7/8" knockouts provided.
heavy duty coupler, required for continuous row mounting. Catalog No. EY COUPLER
S Hook
Slots (8)
7/8” Dia. K.O.
(2 places)
4-3/8”
(111mm)
3-1/8”
(81mm)
11/16” Dia.
K.O.
(2 Places)
48” (1220mm) 87-3/8” (2219mm) 89-3/4" (2279mm)
96" (2441mm)
4-3/8”
(111mm)
3-1/8”
(81mm)
optional occupancy sensor see folio OA60-10
0.0 45.0 90.0 FLUX
0 1547 1547 1547
5 1534 1526 1542 146
15 1425 1428 1434 403
25 1241 1242 1268 575
35 1034 1034 1205 674
45 797 872 1211 729
55 545 753 1058 678
65 283 522 776 513
75 130 269 372 271
85 30 90 42 78
90 4 60 13
95 19 32 15 32
105 35 70 56 62
115 48 90 103 86
125 61 121 120 93
135 73 129 149 91
145 84 115 116 72
155 94 104 117 49
165 102 102 106 29
175 105 98 98 10
180 100 100 100
Page 2 of 2 14 Cell Louver, 90% Downlight, 10% Uplight
48" Length 2 Lamp T5/T8, 96" Length 2 Lamp T5/T8 in Tandem
Job Information Type:
Ordering Information
Explanation of Catalog Number. Example: EYS414FR232UNVHI
Options/Accessories
Stem and Canopy Sets: Suspends fixture 6", 12", 18" or 24" from surface. Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC 24 CSP (24"). Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF. Emergency Pack: Factory-installed emergency power battery pack with charger and inverter. SUFFIX: LP400 (T8). LP550 (T5). Cable Hangers: Adjustable 6"-60". Single Cable and Canopy: Catalog Number: WC60. Single Cable, Straight Cord and Canopy: Catalog Number: WCC60**. Single Cable, Coil Cord and Canopy: Catalog Number: WCCC60**. Chain Hanger Kits: Catalog Number: AH5 CSP.
**Cord, 3-#18 wires.
Specifications
Materials: Housing is die-formed 20 gauge cold rolled steel with full length
channel for thru wiring..
Fixture Ends: 18 gauge cold rolled steel. Louver: 22 gauge cold rolled steel. Side Reflectors: Solid 22 gauge cold rolled steel. Finish: Post painted white acrylic baked enamel.
Specifications (continued)
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
EY
Options:
Add appropriate suffix to catalog
no., ie: (GLR)
Eye-Q LB:
Suspended/
Surface
Fluorescent
Luminaire
S
S=Solid
Sides
Fixture Length:
4=48" 8=96"
Lamp Type:
(By Others)
32=T8 28=T5 54=T5
(Nominal 48")
R
R= 10% Uplight
Reflector
Model No. EYS414FR232UNVHI
LER = FP - 67.3 IW - 59.7 BF - 0.87 Comparative yearly lighting energy cost per
1000 lumens = $3.58
Report Number: G2005315 Catalog Number: EYS414FR232UNVHI Lamps: F32T8 Luminaire: Eye-Q LB with solid sides, 14 cell flat white louver and 10% uplight specular reflector Ballast: B232IUNVHP-B-Triad Report is based on 2850 Lumens per lamp. Efficiency: 80.6% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.1 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 48.000 9.000 Height of Side: 3.960 3.960
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 3735. 3507. 4266. 55 3049. 3429. 4063. 65 2041. 2839. 3388. 75 1377. 1887. 1951. 85 635. 929. 287.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01868278747169696765 02787166656157615754 03716256575248534946 04655548504541474339 05604942453935433834 06554437413531393430 07514033373127353026 08473730342824322724 09443427312622302521
10 41 31 25 29 23 20 27 23 19
ZONE LUMENS % LAMP % FIXT
00-030 1124 19.7 24.5 00-040 1798 31.5 39.2 00-060 3206 56.2 69.8 00-090 4067 71.4 88.6
90-120 180 3.2 3.9 90-130 274 4.8 6.0 90-150 437 7.7 9.5 90-180 525 9.2 11.49
00-180 4592 80.6 100.0
ZONAL LUMEN SUMMARY
Model No. EYS414FR254UNVPG
LER = FP - 69.1 IW - 118.5 BF - 1.00 Comparative yearly lighting energy cost per
1000 lumens = $3.48
Report Number: G2005307 Catalog Number: EYS414FR254UNVPG Lamps: FP54/835 Luminaire: Eye-Q LB with solid sides, 14 cell flat white louver and 10% uplight specular reflector. Ballast: B254-IUNV-E Universal Report is based on 4400 Lumens per lamp. Efficiency: 93.3% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.1 1.1 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 48.000 9.000 Height of Side: 3.960 3.960
0.0 45.0 90.0 FLUX
0 2847 2847 2847
5 2820 2805 2811 266
15 2644 2579 2561 731
25 2318 2220 2059 1013
35 1937 1730 2164 1197
45 1510 1594 2211 1330
55 1039 1394 2011 1274
65 548 1033 1319 935
75 247 454 758 502
85 65 168 90 150
90 6 112 19
95 22 66 23 52
105 43 58 26 65
115 52 179 112 128
125 55 259 258 185
135 57 259 329 174
145 59 192 296 116
155 60 127 186 58
165 64 73 92 22
175 61 50 48 5
180 53 53 53
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 7075. 6411. 7788. 55 5812. 6348. 7722. 65 3952. 5619. 5760. 75 2617. 3186. 3976. 85 1377. 1734. 614.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01999591868381817977 02908376757066716764 03827265666055625753 04756456595247555046 05695749524641504439 06645143474136453935 07594638433631413531 08554235393328373227 09513931363025352925
10 48 36 29 33 27 23 32 26 22
ZONE LUMENS % LAMP % FIXT
00-030 2010 22.8 24.5 00-040 3207 36.4 39.0 00-060 5810 66.0 70.7 00-090 7398 84.1 90.1
90-120 256 2.9 3.1 90-130 441 5.0 5.4 90-150 731 8.3 8.9 90-180 816 9.3 9.9
00-180 8214 93.3 100.0
ZONAL LUMEN SUMMARY
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section 5/Folio K60-15
Voltage:
120, 277 or
UNV=120-277
14= 14 Cell
Louver 1 Row
28= 28 Cell
Louver 2 Rows
F
Finish: F=Flat
White
2
Lamp
Quantity:
2=2 Lamp
2 Lamps in
Tandem
for 96" Units
Ballast Type:
<20THD <10THD
1-2 or 2-2 Lamp Elec. T8 SO * HI * 1-4 Lamp Elec. T8 O4 * H4 * 1-2 or 2-2 Lamp 28W Elec. T5 –PI † 1-2 or 2-2 Lamp 28W or 54W Elec. T5 – PG †† 1-4 Lamp 54W Elec. T5 PV †† LOL T8 Dimming PS *
Other dimming options. Consult factory.
*Instant Start Standard†Instant Start (120V or 277V only)
††Program Rapid Start (UNV only)
NOTE:
For T8 UNV, you must use HI, H4 Ballast Code.
Loading...