Job Information Type:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lens IC Series
Page 1 of 2 2' x 2' Recessed Fluorescent, IC Lens Frame Troffer
Static, 2-6" U Lamp T8
Mounting Methods Dimensions
• UL Listed Type IC Recessed Luminaire (Intended for Direct Thermal Insulation Contact).
• Construction provides optimum thermal performance.
• Ballast mounted with thermal heat sink.
• Ideal for fire rated ceilings.
• Black exterior for cooler ballast operating temperature.
• 5" deep body.
• 71.6% efficient
• 2-9/16" lamp to lens for better lamp obscuration.
• Hemmed over side rails for maximum safety.
• Fixture ends turned-in for safe handling.
• Built-in earthquake clips (patent no. 5,072,344).
• True Mitered corner steel lens frame.
• Spring loaded rooster head latches.
• 18 gauge steel hinges.
• Flat and regressed aluminum doors available.
• Construction to meet Chicago Plenum requirements is available.
23-7/8"
(606mm)
5"
(127mm)
15-11/16"
(398mm)
2"x2-1/2" access plate with two K.O.s (7/8" dia.)
24" (610mm)
5" (127mm)
G
exposed T-grid ceiling.
T
exposed slot T-grid ceiling.
drywall kit. (See options)
1/4" max.
1-1/2" max.
15/16"
or 1"
24"
Type “G”
Fixture
Support (by others)
Drywall Kit
(See Options)
Drywall (by others)
1-7/8" max.
9/16"
24"
earthquake clip
installed
(lay-in grid)
earthquake clip
before
installation
Order Catalog Number: FK92X2 and CF2FK SPACER.
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2008 a Philips Group SECTION 7/Folio Q80-10
Job Information Type:
IC
Standard IC Lens
IY
For NYC Code – I.B.E.W. Manufactured
IX
For NYC Code – Local 3 Manufactured
5½" Deep Body
0.0 45.0 90.0 FLUX
0 1708 1708 1708
5 1700 1698 1702 162 15 1620 1635 1655 462 25 1467 1501 1531 691 35 1231 1274 1328 798 45 904 959 1069 748 55 553 592 651 531 65 313 269 331 302 75 173 141 207 180 85 59 54 68 63 90 000
Model No. ICS2GFSVA26U120SO
LER = FP - 58.4 IW - 56.5 BF - 0.87 Comparative yearly lighting energy cost per
1000 lumens = $3.86
Report Number: G00036 Catalog Number: ICS2GFSVA26U120SO Lamp: (2) T8 U6 Luminaire: IC 2' X 2' with VA lens Ballast: M2-RN-T81LL-D-120 Report is based on 2750 Lumens per lamp.
Efficiency: 71.6% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.720 21.720
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 4199. 4454. 4565. 55 3167. 3390. 3728. 65 2432. 2091. 2572. 75 2195. 1789. 2627. 85 2223. 2035. 2563.
LUMINANCE DATA IN CANDELA/SQ. METER
ZONE LUMENS % LAMP % FIXT
00-030 1315 23.9 33.4 00-040 2113 38.4 53.7 00-060 3392 61.7 86.1 00-090 3938 71.6 100.0
90-180 00000.0000.0
00-180 3938 71.6 100.0
ZONAL LUMEN SUMMARY
Mounting Height
Lengthwise Crosswise
Room Luminaires Luminaires
Size 0 Deg Plane 90 Deg Plane
8.5 10 13 16 8.5 10 13 16
30x30 50 54 58 63 47 51 55 60 40x40 47 50 53 56 44 47 50 53 60x30 52 56 60 64 51 55 58 62 60x60 44 46 47 50 41 43 44 48
100x100 44 44 43 45 42 41 40 41
TYPICAL V.C.P.'s
Lens IC Series
Page 2 of 2 2' x 2' Recessed Fluorescent, IC Lens Frame Troffer
Static, 2-6" U Lamp T8
Options/Accessories
Special Lenses: Substitute VY for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average
weight per square foot. Substitute VI for VA (standard) = .125" nominal pattern 12 with 6.8 oz. average weight per square foot. Radio Interference Filter:
To order one RIF per fixture; SUFFIX: R. To order one RIF per ballast; SUFFIX: B.
Electrical Wiring Options: Consult factory. Drywall Kit: Order Catalog Number: FK92X2.
(Request Folio OA30-10 Rev. A).
Chicago Plenum: SUFFIX: C.
Specifications
Performance: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1,
reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .76. To prevent glare the VCP shall be not less than 41 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 2572 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 66.9%. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing
with side rails
hemmed over and housing ends turned-in for safe handling.
Specifications (continued)
Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86%
reflectance. Rust preventative undercoating. Lenses: VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge, .095" nominal thickness (similar to pattern 12). VY (optional) .125" nominal pattern 12 with 7.8 oz. average weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz. average weight per square foot. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W. UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
1 797673716967686665 2 726762636057615855 3 666054565249545148 4 615348514642494542 5 574842464137444037 6 534438423733413633 7 494034383329373329 8 463631353026343026 9 433428322724322724
10 40 31 26 30 25 22 29 25 22
Lightolier is a Philips group brand
IC Series:
Recessed Lens
suitable for
Direct Thermal
Insulation
Contact
Body Style:
S=Static
Fixture
Width
Lens Shielding
Type:
VA=Virgin acrylic (standard),
see options and consult factory
Voltage:
120, 277 or
UNV=120-277
Ceiling Type:
G= Grid
(lay-in T bar)
T= Slot grid
Lens Frame:
FS=Flat steel frame. RA=Regressed
aluminum frame.
FA=Flat aluminum
frame.
Lamp Type/
Fixture Length:
(By Others)
6U=6"U Lamp T8
(Nominal 24")
Lamp
Quantity
2=2 lamps
Ballast Type:
<20THD <10THD
1-2 Lamp Elec. T8 SO * HI *
*Instant Start Standard
NOTE: For T8 UNV, you must use H
I
Ballast Code.
2S VA 6U
Options:
Lamps Flex EM Pack Fuse
(Consult your
representative)
Ordering Information
Explanation of Catalog Number. Example: ICS2GFSVA26UUNVHI
-