Lightolier EL4 User Manual

EL4 Series Emergency Lighting EL4
12.6"
(32.0 cm)
2.5"
(6.4 cm)
6.4"
(17.0 cm)
40
35
30
25
20
15
10
5
0
-5 -4 -3 -2 -1 012345
.1
.2
.3
.5
HORIZONTAL
FEET
40
35
30
25
20
15
10
5
0
-5 -4 -3 -2 -1 012345
.1
.2
.3
.5
1
VERTICAL
FEET
Page 1 of 1 6 volt 24 Watts Thermoplastic Housing
The EL4 Series is an architectural grade four-head emergency light primarily suited for ceiling mounted applications. This product features innovative architectural styling and technologically advanced features.
Complete fixture consists of unit and two lamp heads. Lamp Head Photometrics (per lamp)
How to Specify:
EL4
Model Series
EL4
Enclosure Color
W = White
Battery
N = NiMH
Options
I = Infrared Remote Sensor
TD = Time Delay
B = Black
Features
1. Illumination: Four rotatable reflector assemblies with adjustable beam pat-
terns. Unit includes 6 VDC, 6 watt halogen lamps housed in impact resistant
lamp covers.*
2. Housing: Impact resistant, injection molded UL 94-5VA flame retardant
thermoplastic housing. UV-stabilized to resist discoloration. White finish is standard, black is optional.
3. Mounting: Unit is either ceiling or wall mountable.
4. Standard Self-Testing/Self-Diagnostics: Unit runs an internal test every
five seconds for secondary voltage, charge current, battery voltage, and LED illumination. Performs automatic 1 minute discharge test every 30 days and 30 minute discharge test every 180 days meeting and exceeding UL 924 and NFPA 101 requirements. The Infrared Option allows a remote control to initi­ate a 5 second and 30 minute self-test in addition to the standard 1 minute and 90 minute manual test capabilit y.
5. Electronics: 120/277 VAC dual voltage input. Microprocessor controlled
charge, transfer and monitoring system. Charging system is complete with low voltage disconnect, AC lockout, and brownout protection. Includes an AC indicator/systems status lamp and manual test switch.
6. Battery: Maintenance free, sealed nickel metal hydride battery with 10 year
life and an operating temperature bet ween 14°F (-10°C) and 113°F (45°C). NiMH battery is a non-toxic, environmentally friendly product which is recy­clable.
7. Input Power Requirements:
120 VAC - .109 amps, 12.6W 277 VAC - .048 amps, 13.10W
1
Options
I = Infrared Remote Sensor
1
TD = Time Delay
Note:
1
For u se with re mote cont rol which is ordered s eparatel y. Ite m number: I Remote
Accessories
IREMOTE - Infrared Remote Control
*Replacement Lamping: No. 784, T2.25, G-4 Two Pin Base, 6 Volt, 6 Watt Miniature Lamp.
Job Information Type:
Job Name:
Cat. No.:
Warranty
Electronics: 3 years, Battery: 5 years full, 5 years pro-rata
Code Compliance
Lightolier is a Philips group brand
UL 924 listed, NFPA 101.
Lamp(s):
Notes:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710