Page 1 of 3 Energos Control System 3-Light T8 per 4' (121.92cm) (Nominal) Louver
Feature Specifications – Energos Control System (For standard Energos fixtures consult appropriate EG spec sheets)
Feature Specifications
Electrical
Dedicated low voltage (24 VDC) circuit controls the Energos Control Systems. The
line voltage circuits control all the standard ballast functions including A/B switching, Dimming and Emergency Battery Pack operations.
Occupancy Sensors:
• Time delay is factory pre-set to 30 minutes.
• Time delay can be field adjusted from 30 minutes to a minimum of 30 seconds.
• Daylight hold-off is factory pre-set to 120 ft-candles (1291.67m-candles).
• Daylight hold-off is field adjustable from 120 ft-candles (1291.67m-candles)
down to 10 ft-candles (107.64m-candles).
• Sensors are designed for a detection area (sensitivity diameter) of 16'
(487.68cm) when suspended 10' (304.80cm) AFF. Lowering the sensor produces
a smaller area of detection. See chart and diagram for additional information.
ECS occupancy sensors are available in two variations:
• Mounted in the end cap.
• The middle of an 8" (243.84cm) module.
The ECS system control-center is the Power Pack. The Power Pack, contained in
each Master Module, interrupts the circuits when parameters dictate. The Power
Pack can control up to 600 watts 120 VAC, and 1300 watts 277 VAC. A maximum
of 10 sensors can be used on a single Power Pack. There is no limitation to the
number of Power Packs that can be "daisy-chained" to a single ECS circuit.
Emergency battery packs can be used in conjunction with ECS for emergency
egress lighting since all listed packs operate for a minimum of 90 minutes.
EM Packs can be used as momentary lighting for emergency circuit for power
transitions, and smaller packs are recommended for this purpose.
Dimming ballasts can be used in conjunction with ECS. However, the control
system will only perform ON or OFF operations and will not affect the level of dimming set by the dimming ballasts.
Factory installed ballast disconnect allows the ballast to be disconnected from and
reconnected to incoming power under load without turning the entire circuit off.
Serial Row Linking (SRL) provides multiple continuous row communication.
For every run that SRL is required, order the appropriate SRL end set from page 2
of this Specification Sheet. Consult Energos Application Guide for more detailed
definitions and examples.
Mountings
Cable suspension distances are on 48" (121.92cm) and 96" (243.84cm) centers,
and consist of a 4 1/2" (11.43cm) diameter canopy finished white enamel. A 1/16"
(0.16cm) diameter stainless steel aircraft cable accomplishes suspension and is
adjustable from 12" (30.48cm) to 36" (91.44cm). Power feeds are 18 gauge silver
braided cord with clear jacket.
1. End Cap Sensor Mounting2. Mid-mounted 8' (243.84cm)
Sensor Mounting
2. Order a minimum of one master per run. Please see Application Guide for
master requirements on runs that exceed 16' (487.68cm).
3. Order the required remaining Master and Slave modules to complete the run.
4. Order Power Feed End Set.
5. Order one CABLE ASSEMBLY per MODULE minus one per run.
6. Order additional Single Cable & Cord Sets for every Master Module in run.
ECS End Sets
Single Sensor
End Set EC1SE36W
Single Sensor SRL
End Set EC1SR36W
Dual Sensor
End Set EC1DE36W
Dual Sensor SRL
End Set EC1DR36W
Single Cable &
Power Cord EGCC36
16' Run: 8' (243.84cm) Master Module, 8' (243.84cm) Slave Module, standard
Energos End Set, and Intermediate Cable Assembly.
16' Run: 8' (243.84cm) Master Module, 8' (243.84cm) Slave Module, Single
Sensor End Set, and Intermediate Cable Assembly.
16' Run: 8' (243.84cm) Master Module, 8' (243.84cm) Slave Module, Single
Sensor End Set, and Intermediate Cable Assembly.
Notes:
1. See page 1 of Specification Sheet or consult Application Guide for the definition of Serial
Row Linking (SRL).
2. Consult the matching EG specification sheet for Luminaire related specifications (i.e.
Housing materials, shielding, mounting dimensions, and photometry).
Standard End
Set EG1EC36W
SRL Standard
End Set EC1ER36W
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
*25°C Rating
All data is per 1 lamp on a two lamp system at 277 VAC.
Data is based on Osram Sylvania specifications.
When ordering no lamps provided by Lightolier, use lamp code “Z”.
Do not alter lumen values or ballast factor light losses when completing
calculations using Energos IES files. Files have already been adjusted. The lumen
value for the lamp (within a Lighting Design program) will be the IES Ouput value
shown on this table.
The lamp life table demonstrates the effects of shortened cycle-times with both
program start and instant start ballasts. The graph shows that instant ballasts
are susceptible to shortened lamp life if short cycle periods of less than 3 hours
are used. For cycle periods of greater than 3 hours program start ballast are not
required.
Lamp Life Table using program start and instant start ballasts.