Lightolier EC1-3 User Manual

Lighting Systems EC1-3
Coverage Diameter
Sensor Height AFF
Energos Occupancy Sensor
Coverage Zone Chart
16' 0" 14' 5"
12' 10"
11' 3"
7' 0"
8' 0"
9' 0"
10' 0"
Page 1 of 3 Energos Control System 3-Light T8 per 4' (121.92cm) (Nominal) Louver
Feature Specifications – Energos Control System (For standard Energos fixtures consult appropriate EG spec sheets)
Feature Specifications
Electrical
Dedicated low voltage (24 VDC) circuit controls the Energos Control Systems. The line voltage circuits control all the standard ballast functions including A/B switch­ing, Dimming and Emergency Battery Pack operations.
Occupancy Sensors:
• Time delay is factory pre-set to 30 minutes.
• Time delay can be field adjusted from 30 minutes to a minimum of 30 seconds.
• Daylight hold-off is factory pre-set to 120 ft-candles (1291.67m-candles).
• Daylight hold-off is field adjustable from 120 ft-candles (1291.67m-candles) down to 10 ft-candles (107.64m-candles).
• Sensors are designed for a detection area (sensitivity diameter) of 16' (487.68cm) when suspended 10' (304.80cm) AFF. Lowering the sensor produces
a smaller area of detection. See chart and diagram for additional information.
ECS occupancy sensors are available in two variations:
• Mounted in the end cap.
• The middle of an 8" (243.84cm) module.
The ECS system control-center is the Power Pack. The Power Pack, contained in each Master Module, interrupts the circuits when parameters dictate. The Power Pack can control up to 600 watts 120 VAC, and 1300 watts 277 VAC. A maximum of 10 sensors can be used on a single Power Pack. There is no limitation to the number of Power Packs that can be "daisy-chained" to a single ECS circuit.
Emergency battery packs can be used in conjunction with ECS for emergency egress lighting since all listed packs operate for a minimum of 90 minutes. EM Packs can be used as momentary lighting for emergency circuit for power transitions, and smaller packs are recommended for this purpose.
Dimming ballasts can be used in conjunction with ECS. However, the control system will only perform ON or OFF operations and will not affect the level of dim­ming set by the dimming ballasts.
Factory installed ballast disconnect allows the ballast to be disconnected from and reconnected to incoming power under load without turning the entire circuit off.
Serial Row Linking (SRL) provides multiple continuous row communication. For every run that SRL is required, order the appropriate SRL end set from page 2 of this Specification Sheet. Consult Energos Application Guide for more detailed definitions and examples.
Mountings
Cable suspension distances are on 48" (121.92cm) and 96" (243.84cm) centers, and consist of a 4 1/2" (11.43cm) diameter canopy finished white enamel. A 1/16" (0.16cm) diameter stainless steel aircraft cable accomplishes suspension and is adjustable from 12" (30.48cm) to 36" (91.44cm). Power feeds are 18 gauge silver braided cord with clear jacket.
1. End Cap Sensor Mounting 2. Mid-mounted 8' (243.84cm) Sensor Mounting
Height of Sensor Broadcast Diameter Task Diameter
10' 0" (304.80cm) 16' 0" (487.68cm) 8' 0" (243.84cm)
9' 0" (274.32cm) 14' 5" (427.99cm) 7' 3" (214.12cm) 8' 0" (243.84cm) 12' 10" (391.16cm) 6' 5" (184.15cm) 7' 0" (213.36cm) 11' 3" (336.04cm) 5' 7" (154.18cm)
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group •
C0808
Lighting Systems EC1-3
Page 2 of 3 Energos Control System 3-Light T8 per 4' (121.92cm) (Nominal) Louver
Control Ordering Information
Family Series Lamping &
Distribution
EC 1
3 = 3 lamp,
open top
6 = 3 lamp,
slotted top reflector
See Chart on Page 3
Lamp
See Chart on Page 3
ShieldingBallast
P
P = Parabolic
Louver
4 = 4' (121.92cm) 8 = 8' (243.84cm)
VoltageLength
6 = 120 Vac Master 7 = 277 Vac Master 8 = 120 Vac Slave 9 = 277 Vac Slave
Finish
A = Aluminum W= White
Options (Blank)
4 = 4 through wires 5 = 5 through wires 6 = 6 through wires D = Dual Switch T = Tandem Switch E = Emergency
Ordering Instructions
End Cap ECS Systems
1. Order Master 4' (121.92cm) or 8' (243.84cm) ECS Module.
2. Order Power Feed End Set.
ECS Sensor Sample Runs
4' Run: 4' (121.92cm) Master Module with Single Sensor End Set.
8' Run: 8' (243.84cm) Master Module and standard Energos End Set.
8' Run: 8' (243.84cm) Master Module and Dual Sensor End Set.
12' Run: 8' (243.84cm) Master Module, 4' (121.92cm) Slave Module, Dual
Sensor End Set, and Intermediate Cable Assembly.
Continuous Row Mounted ECS Systems:
1. Determine run length
2. Order a minimum of one master per run. Please see Application Guide for master requirements on runs that exceed 16' (487.68cm).
3. Order the required remaining Master and Slave modules to complete the run.
4. Order Power Feed End Set.
5. Order one CABLE ASSEMBLY per MODULE minus one per run.
6. Order additional Single Cable & Cord Sets for every Master Module in run.
ECS End Sets
Single Sensor
End Set EC1SE36W
Single Sensor SRL
End Set EC1SR36W
Dual Sensor End Set EC1DE36W
Dual Sensor SRL End Set EC1DR36W
Single Cable & Power Cord EGCC36
16' Run: 8' (243.84cm) Master Module, 8' (243.84cm) Slave Module, standard Energos End Set, and Intermediate Cable Assembly.
16' Run: 8' (243.84cm) Master Module, 8' (243.84cm) Slave Module, Single Sensor End Set, and Intermediate Cable Assembly.
16' Run: 8' (243.84cm) Master Module, 8' (243.84cm) Slave Module, Single Sensor End Set, and Intermediate Cable Assembly.
Notes:
1. See page 1 of Specification Sheet or consult Application Guide for the definition of Serial Row Linking (SRL).
2. Consult the matching EG specification sheet for Luminaire related specifications (i.e. Housing materials, shielding, mounting dimensions, and photometry).
Standard End Set EG1EC36W
SRL Standard
End Set EC1ER36W
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group •
C0808
Lighting Systems EC1-3
Page 3 of 3 Energos Control System 3-Light T8 per 4' (121.92cm) (Nominal) Louver
Ballast Ordering Information
Design Lamp Type Ballast Factor Start Type THD %
D T8 0.71 Program <10 E T8 0.88 Program <10 H Dim T8 1.00/.05 Program <10
Lamp and Ballast System Data
Design
*25°C Rating All data is per 1 lamp on a two lamp system at 277 VAC. Data is based on Osram Sylvania specifications. When ordering no lamps provided by Lightolier, use lamp code “Z”.
Lamp Type
(T8 or T5)
DA T8 0.71 <10 28 2725 3000 2199 20.0 96.74 24000 Program DB T8 0.71 <10 28 2725 3500 2199 20.0 96.74 24000 Program DC T8 0.71 <10 28 2725 4100 2199 20.0 96.74 24000 Program DD T8 0.71 <10 30 2850 3000 2299 21.5 94.12 24000 Program DE T8 0.71 <10 30 2850 3500 2299 21.5 94.12 24000 Program DF T8 0.71 <10 30 2850 4100 2299 21.5 94.12 24000 Program DG T8 0.71 <10 32 3000 3000 2420 23.0 92.61 24000 Program DH T8 0.71 <10 32 3000 3500 2420 23.0 92.61 24000 Program
DI T8 0.71 <10 32 3000 4100 2420 23.0 92.61 24000 Program
DJ T8 0.71 <10 32 3100 3000 2501 23.0 95.70 30000 Program DK T8 0.71 <10 32 3100 3500 2501 23.0 95.70 30000 Program DL T8 0.71 <10 32 3150 4100 2541 23.0 97.24 30000 Program
EA T8 0.88 <10 28 2725 3000 2725 25.5 94.04 24000 Program EB T8 0.88 <10 28 2725 3500 2725 25.5 94.04 24000 Program EC T8 0.88 <10 28 2725 4100 2725 25.5 94.04 24000 Program ED T8 0.88 <10 30 2850 3000 2850 27.5 91.20 24000 Program EE T8 0.88 <10 30 2850 3500 2850 27.5 91.20 24000 Program
EF T8 0.88 <10 30 2850 4100 2850 27.5 91.20 24000 Program EG T8 0.88 <10 32 3000 3000 3000 29.0 91.03 24000 Program EH T8 0.88 <10 32 3000 3500 3000 29.0 91.03 24000 Program
EI T8 0.88 <10 32 3000 4100 3000 29.0 91.03 24000 Program EJ T8 0.88 <10 32 3100 3000 3100 29.0 94.07 24000 Program EK T8 0.88 <10 32 3100 3500 3100 29.0 94.07 24000 Program EL T8 0.88 <10 32 3150 4100 3150 29.0 95.59 24000 Program HG T8 DIM 1.0 / 0.5 <10 32 2850 3000 2850 / 143 34 / 8 83.80 NA Program HH T8 DIM 1.0 / 0.5 <10 32 2850 3500 2850 / 143 34 / 8 83.80 NA Program
HI T8 DIM 1.0 / 0.5 <10 32 2850 4100 2850 / 143 34 / 8 83.80 NA Program
Ballast
Factor (BF)
Ballast
THD (%)
Lamp Rated
Wattage
Lamp
Rated
Output
Design Lamp Type Wattage
A T8 28 2725 3000 B T8 28 2725 3500 C T8 28 2725 4100 D T8 30 2850 3000 E T8 30 2850 3500 F T8 30 2850 4100 G T8 32 3000 3000 H T8 32 3000 3500
I T8 32 3000 4100
J T8 32 3100 3000 K T8 32 3100 3500 L T8 32 3150 4100
Lamp Color
(Kelvin)
IES Output
(lumens)
Lamp Ordering Information
Rated Output
(Lumens)
System
Input
Watts
System
Efficacy
(lum/watt)
System
Lamp Life
(Hours)
Color (K)
Start Type
Do not alter lumen values or ballast factor light losses when completing calculations using Energos IES files. Files have already been adjusted. The lumen value for the lamp (within a Lighting Design program) will be the IES Ouput value shown on this table.
The lamp life table demonstrates the effects of shortened cycle-times with both program start and instant start ballasts. The graph shows that instant ballasts are susceptible to shortened lamp life if short cycle periods of less than 3 hours are used. For cycle periods of greater than 3 hours program start ballast are not required.
Lamp Life Table using program start and instant start ballasts.
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group •
C0808