Lightolier E7059 User Manual

Ceiling Cutout: 6 9/16" Dia.
Reflector Trims Frame-In Kit Lamp
E7059CLW Specular Clear finish with white flange E610 A19, 100W max. E7059CLP Specular Clear finish with polished flange A21, 150W max. E7059CL Specular Clear finish with molded trim ring (flangeless) E7059 Add suffix for other finishes (see options)
6-1/2" Flush
7-1/4" Overlap
12
34
5
6
7
1-1/8" max. Ceiling Thickness
3"
1" min.­2-1/8" max. (Ceiling Runner)
4-1/2"
13-1/4"
10-1/4"
Molded
Trim Ring
Flush Trim
(Molded trim
ring removed)
Overlap Self-Flange
Matte White
or polished
Top View
Calculite
®
Incandescent Open Downlight E7059
Page 1 of 2 6" Aperture A19 / A21 Horizontal Lamp
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902
Features
1. Socket Cup: Heat dissipating die-formed aluminum contains medium base
porcelain socket with nickel plated screw shell wired with No 18 SF1 leads to J-Box. Installs on reflector with positive position locking springs to assure proper optical alignment of lamp to reflector — attached without tools. Can be adjusted without tools to accommodate two different lamp sizes.
2. Mounting Brackets: Adjust vertically from inside of fixture. Durable 16 ga. steel construction. Use with 3/4" or 1 3/4" lathing channels, or1/2" (11/16" O.D.) EMT pipe (by others) or Lightolier accessory mounting bars.
3. Retaining Springs: Precision tooled springs secure reflector to mounting frame for quick tool-less installation.
4. Reflector: 16 ga. Specular Alzak
®
aluminum, 50° visual cut-off to lamp and lamp image. Available with white or polished flange, or with removable white molded trim ring (field paintable).
5. Junction Box: 14 ga. steel, 4" x 3 1/2" x 2" box allows inspection from below.
6. Thermal Protector: Meets NEC and UL requirements. Insulation must be kept 3" away from fixture sides and wiring compartments and must not be placed above fixture in a manner which will entrap heat.
7. Mounting Frame: Die-cast aluminum suitable for dry or plaster ceilings. Provides flangeless trim in plaster ceiling.
Other Reflector Finish Options
Comfort Clear Diffuse CCD Specular Gold GD
For additional finishes consult factory (GD not available with polished flange)
Flange Options
White W Polished Flange P Flangeless Leave Blank (molded trim ring)
Options & Accessories
18" Mounting Bars 1950 (set of 2) 27" Mounting Bars 1951 (set of 2) T-Bar Anchor Clips 1956 (set of 4, for 1950 & 1951 bars) Existing Ceiling Clips 7998 (set of 2) Sloped Ceiling Adapters 7920 (see SCA specification sheet) Step Down Transformer 7997 (see 7997 specification sheet) Chicago Air Plenum LC (add suffix to Frame-in Kit)
Electrical
UL listed for maximum of 8 No. 12, 75°C through branch circuit supply conduc­tors, or 60°C conductors for end of run.
Labels
UL Listed for damp locations, I.B.E.W.
Alzak®is a registered trademark of ALCOA.
80% Ceiling; 50% Walls; 20% Floor
Room Surface Reflectances:
150 Watt A-21 2880 Lumens Per Lamp
RCR = 10 (Rm. Width - Mtg. Ht. above work plane)
RCR = 5 (Rm. Width - 2Mtg. Ht. above work plane)
RCR = 1 (Rm. Width - 10 x Mtg. Ht. above work plane)
Area Per Fixture In Square Feet
Initial Footcandles
13 141211
8
975 6 10
20015010050
60
50
40
30
20
20
15
90
60
3030
90°
Plane
0°
Plane
180° Plane
Coefficients of Utilization
% Effective Ceiling Cavity Reflectance
80 70 50 30 10 0
Room Cavity Ratio
20% Floor Cavity Reflectance
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
.80 .78 .76 .78 .77 .75 .75 .74 .73 .73 .72 .71 .70 .69 .69 .68 .75 .73 .70 .74 .72 .70 .72 .70 .68 .69 .68 .67 .68 .66 .65 .64 .71 .68 .65 .70 .67 .65 .68 .66 .64 .66 .64 .63 .65 .63 .62 .61 .67 .63 .61 .66 .63 .61 .65 .62 .60 .63 .61 .59 .62 .60 .58 .58 .63 .59 .57 .62 .59 .56 .61 .58 .56 .60 .57 .55 .59 .57 .55 .54 .60 .56 .53 .59 .56 .53 .58 .55 .53 .57 .54 .52 .56 .54 .52 .51 .56 .52 .50 .56 .52 .49 .55 .52 .49 .54 .51 .49 .53 .51 .49 .48 .53 .49 .46 .52 .49 .46 .52 .48 .46 .51 .48 .46 .50 .48 .46 .45 .49 .46 .43 .49 .45 .43 .48 .45 .43 .48 .45 .43 .47 .44 .42 .41 .47 .43 .40 .46 .43 .40 .46 .42 .40 .45 .42 .40 .45 .42 .40 .39
1 2 3 4 5 6 7 8 9
10
% Wall Reflectance
ZONAL
DEG. 0 45 90 135 180 FLUX 0 1238 1238 1238 1238 1238 5 1297 1304 1282 1246 1218 121 15 1828 1690 1620 1455 1318 448 25 1859 1971 1834 1617 1362 814 35 940 954 938 831 751 560 45 165 157 140 105 83 102 55 4 4 4 3 3 3 65 1 1 1 1 1 1 75 1 1 1 1 1 1 85 0 0 0 0 0 0 90 0 0 0 0 0
ZONE LUMENS LAMP FIXT
0-30 1383 48.0 67.5 0-40 1943 67.5 94.8 0-60 2048 71.1 99.9 0-90 2050 71.2 100.0 90-180 0 0.0 0.0 0-180 2050 71.2 100.0
Zonal Summary
Candlepower Summary
ITL, Inc. test report No. 22532 Date: 10-26-77
Spacing Ratio = 1.3
Use quick calculator chart to determine spacing of luminaires for desired level of illumina­tion. Conversion Factor: 100W A19 (Clear): F.C. X 0.60; (Gold): F.C. x 0.55 150W A21 (Gold): F.C. x 0.90.
Calculite
®
Incandescent Open Downlight E7059
Page 2 of 2 6" Aperture A19 / A21 Horizontal Lamp
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) • A0902
Job Information Type:
Loading...