Lightolier DPA2G32LS432 User Manual

Deepcel Plus DPA2G32LS432
Page 1 of 2 2' x 4' Recessed Fluorescent, 3", 32 Cell, Parabolic Louver
Static or Air Supply/Return, 4 Lamp, T8 or T5
• 5" deep body.
• 64.1% efficient.
• Clean contoured interior.
• Eyeleted heat removal vents in fixture ends.
• One piece housing has ribbed construction for added strength.
• Hemmed over side rails for safe handling.
• Fixture ends turned-in for safe handling.
• Built-in earthquake clips (patent no. 5,072,344).
• Pre-anodized aluminum parabolic louver.
• Vertical grain louver eliminates reflected lamp images on cross baffle.
• Spring loaded latches.
• 18 gauge steel hinges.
• Louver frame with integral positive light stop.
• Louver has protective film dust guard.
• Construction to meet NYC Code or Chicago Plenum requirements is available.
Mounting Methods Dimensions
exposed T-grid ceiling.
G
24"
concealed Z-spline ceiling.
F
24-11/16"
drywall kit.
Type “G” Fixture
1/4" max.
1-1/2" max.
15/16" or 1"
1-1/8" min. 3-3/4" max.
Support (by others)
Drywall Kit (See Options)
Drywall (by others)
exposed slot T-grid ceiling.
T
24"
plaster ceiling/flanged.
F
Opening
Plaster 24-1/8"
24-11/16"
1-7/8" max.
9/16"
1-1/8" min. 3-3/4" max.
13/16"
3" Nominal
24" (610mm)
6" (152mm) Air supply slots
2" x 2-1/2" access plate with two K.O.s (7/8" dia.)
39-1/4" (997mm)
47-31/32" (1218mm)
Job Information Type:
Job Name:
Cat. No.:
5"
(127mm)
(DPA only)
Order Catalog Number: FK92X4.
08/07
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company
Section 2/Folio G51-50 Rev. A
Deepcel Plus DPA2G32LS432
Page 2 of 2 2' x 4' Recessed Fluorescent, 3", 32 Cell Parabolic Louver
Static or Air/Return, 4 Lamp, T8 or T5
Photometry Model No. DPA2G32LS432120O4
SEMI-SPECULAR 32 CELL LOUVER
THIS REPORTIS BASEDON PUBLISHEDINDUSTRY PROCEDURES• FIELDPERFORMANCE MAYVARY FROMLABORATORY PERFORMANCE.
LER = FP - 56.7 IW - 110.9 BF - 0.86 Comparative yearly lighting energy cost per 1000 lumens = $4.23
coefficients of utilization — zonal cavity method
RF 20 20 20 RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1 71 69 67 65 63 62 63 61 60 2 66 62 58 59 56 54 57 54 52 3 61 56 51 53 49 47 51 48 46 4 57 50 45 48 44 41 46 43 40 5 52 45 40 43 39 36 42 38 36 6 49 41 36 39 35 32 38 35 32 7 45 37 32 36 32 29 35 31 28
room cavity ratio
8 42 34 29 33 29 26 32 28 26 9 40 32 27 31 26 23 30 26 23
10 37 29 24 28 24 21 28 24 21
visual comfort probability (VCP) average 100 fc; reflectances 80/50/20
room size ceiling height ceiling height WL8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 82 76 71 76 81 76 73 79
20 30 84 79 74 71 83 78 74 71 20 40 85 81 77 73 85 80 77 73 20 60 87 82 79 76 86 82 79 75
30 20 85 80 73 75 85 80 74 77 30 30 87 82 75 71 86 82 75 70 30 40 88 83 78 73 87 83 78 72 30 60 89 85 80 75 88 85 80 74 30 80 89 86 82 77 89 86 81 76
40 20 86 82 77 76 86 82 78 78 40 30 88 84 78 72 87 84 78 72 40 40 89 85 81 74 88 85 80 73 40 60 89 86 82 76 89 86 82 75 40 80 90 87 83 78 90 87 83 77 40 100 91 88 85 79 90 88 84 79
60 30 88 84 80 74 88 84 80 74 60 40 89 86 82 76 89 86 82 75 60 60 90 87 83 78 90 87 83 77 60 80 91 88 84 79 90 88 84 79 60 100 91 88 85 81 91 89 85 80
100 40 89 86 83 78 89 86 83 77 100 60 90 87 84 80 90 87 84 79 100 80 91 88 86 81 91 88 85 80 100 100 91 89 87 83 91 89 86 82
luminaries lengthwise
luminaries crosswise
Ordering Information
Explanation of Catalog Number. Example: DPA2G32LS432120O4CP
2
Cells:
of 6
of 6
of 8
Louver Finish:
L = Low
iridescence Semi-specular (standard)
P = Low
iridescence Specular
W =White Baked
Enamel
is ribbed for
Louver is
Deepcel Plus
Parabolic:
Pre-anodized
aluminum
louver
DP
DY
ND
Options/Accessories
Plaster Frame: Catalog Number: PF24. Continuous Row Installation: For F type fixtures, half width flanges are required between fixtures. Order Catalog Number: 2FC TRIM CSP (each joint). Radio Interference Filter: SUFFIX: B. Electrical Wiring Options: Consult factory. Air Closure Strip: Drywall Kit: Order Catalog Number: FK92X4. (Request Folio OA30-10 Rev. A). Chicago Plenum: SUFFIX: CP.
Specifications
Performance: In an installation of 4 lamp 32W luminaires in a room cavity ratio of 1,
reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .69. To prevent glare the VCP shall be not less than 83 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 1138 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 63.9%. Air Handling (DPA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing rigidity with side rails hemmed over and housing ends turned-in for safe handling. pre-anodized aluminum (Coilzak
Body Style:
A=Air Supply S=Static
Standard Deepcel
For NYC Code – I.B.E.W. Manufactured
For NYC Code – Local 3 Manufactured
SUFFIX: ACS4 (factory installed).
Fixture
Width
5½" Deep Body
To order one RIF per fixture; SUFFIX: R. To order one RIF per ballast;
®
or equal.
Ceiling Type:
G= Grid
(lay-in T bar)
F= Flanged (over
lap) Z spline and plaster frame
T= Slot grid or
two-directional concealed T (see options)
Number of
12=2 rows
18=3 rows
32=4 rows
S
Single "V"
Reflector
Specifications (continued)
Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester
enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi­specular anodized vertical grain aliminum reflector sheet is standard. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is with­in 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W. UL and ULc Listed.
4
Lamp
Quantity
Lamp Type/
Fixture Length:
32=32W T8 28=28W T5 54=54W T5
(Nominal 48")
Options:
Voltage:
120, 277 or
UNV=120-277
Ballast Type:
2-2 Lamp Elec. T8 SO * H 1-4 Lamp Elec. T8 O4 * H4 * 2-2 Lamp 28W Elec. T5 – P 2-2 Lamp 28W Elec. T5 – PG †† 1-4 Lamp 54W Elec. T5 – PV ††
LOL T8 Dimming PS Other dimming options. Consult factory.
*Instant Start Standard†Instant Start (120, 277 or UNV)
††Program Rapid Start (UNV only) NOTE:
For T8 UNV, you must use HI, H4 Ballast Code.
Add appropriate
suffix to catalog no.,
ie: (CP)
<20THD <10THD
I *
I
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company
Section 2/Folio G51-50 Rev. A