Lightolier DPA2G16LS2FT, DPA2G16LS2U User Manual

MOUNTING METHODS DIMENSIONS
G
exposed T-grid ceiling.
T
exposed slot T-grid ceiling.
F
concealed Z-spline ceiling.
F
T
direct concealed two directional T-grid ceiling. (see options for
splay trim)
drywall kit. (See options)
1/4" max.
15/16" or 1"
24"
24-11/16"
1/4" max.
3/8"
24"
Type “G” Fixture
15/16"
Ceiling Opening 24-5/16" x 24-5/16"
Support (by others)
Drywall Kit (See Options)
Drywall (by others)
13/16"
Plaster
Opening
24-1/8"
24-11/16"
1-1/8" min. 3-3/4" max.
9/16"
24"
1-1/2" max.
1-7/8" max.
1-7/8" max.
1-1/8" min. 3-3/4" max.
23-7/8"
(606mm)
15-11/16"
(398mm)
5"
(127mm)
Air supply slots (DPA only)
2"x 2-1/2" access plate with two K.O.s (7/8" dia.)
C
L
5"
(127mm)
24" (610mm)
2-11/16"
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 2/Folio G51-38
FEATURES
• 5" deep body.
• 69.4% efficient (2 lamp TT5).
• Clean contoured interior.
• Eyeleted heat removal vents in fixture ends.
• One piece housing.
• Black exterior for cooler ballast operating temperature.
• Hemmed over side rails for safe handling.
• Fixture ends turned-in for safe handling.
• Built-in earthquake clips (patent no. 5,072,344).
• Pre-anodized aluminum parabolic louver.
• Vertical grain louver eliminates reflected lamp images on cross baffle.
• Spring-loaded rooster head latches.
• 18 gauge steel hinges.
• Louver frame with integral positive light stop.
• Louver has protective film dust guard.
• Construction to meet Chicago Plenum requirements is available.
DEEPCEL plus
DPA2G16LS2FT OR 2U
Page 1 of 2 2'x2' RECESSED FLUORESCENT, 3" DEEP, 16 CELL PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, 2 LAMP TWIN TUBE T5 OR 1 5/8"U LAMP T8
PHOTOMETRY
MODEL NO. DPA2G16LS2FT
coefficients of utilization — zonal cavity method
RF 20 20 20 RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1777572 706867 686665 2716763 636057 615856 3665955 565349 555149 4615348 514643 494542 5564842 464137 444037 6524337 413633 403632 7483933 373229 363229 8443530 342926 332926 9413227 312623 312623
10 39 30 25 29 24 21 28 24 21
visual comfort probability (VCP) average 100 fc; reflectances 80/50/20
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 75 66 58 63 71 63 55 50
20 30 77 70 62 60 74 67 60 52 20 40 79 72 66 63 77 70 64 56 20 60 81 74 69 66 79 72 67 60
30 20 79 72 61 61 77 69 59 52 30 30 81 74 65 59 79 72 63 54 30 40 82 76 69 62 81 74 67 57 30 60 83 78 71 65 82 76 70 61 30 80 84 79 73 67 83 78 72 64
40 20 81 75 66 63 79 72 64 55 40 30 83 77 69 61 81 75 68 57 40 40 84 79 72 64 83 77 71 60 40 60 85 80 74 67 84 79 73 63 40 80 86 81 76 69 85 80 75 66 40 100 87 82 78 71 86 81 77 68
60 30 84 78 72 65 82 77 70 61 60 40 85 80 74 67 84 79 73 64 60 60 86 81 76 69 85 80 75 66 60 80 86 83 77 71 86 81 77 69 60 100 87 84 79 73 86 82 78 71
100 40 85 80 75 69 84 78 74 66 100 60 86 82 77 72 85 80 76 69 100 80 87 83 79 74 86 82 78 71 100 100 88 84 81 75 87 83 80 73
room cavity ratio
luminaries lengthwise
luminaries crosswise
ORDERING INFORMATION
Explanation of Catalog Number. Example: DPA2G16LS2FT120SBRF
OPTIONS & ACCESSORIES
PLASTER FRAME: Catalog Number: PF22. CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are required between fixtures. Order Catalog Number: S2FCTRIM (each joint). SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ22 S2 SPLAY TRIM. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS: Consult factory. AIR CLOSURE STRIP. SUFFIX: ACS2. (factory installed). DRYWALL KIT: Order Catalog Number: FK92X2. Request Folio OA30-10. CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
PERFORMANCE: In an installation of 2 lamp 40W luminaires in a room cavity
ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .75. To prevent glare the VCP shall not be less than 85 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 1031 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 70.3%. AIR HANDLING (DPA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends.
SPECIFICATIONS (continued)
MATERIALS: Chassis parts are die-formed code gauge cold rolled steel.
Housing is ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal). FINISH: Chassis exterior–black baked polyester enamel. Cavity– white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi-specular anodized vertical grain aluminum reflector sheet is standard. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W. UL and ULc Listed.
DP
DEEPCEL PLUS 3” PARABOLIC:
Pre-anodized
aluminum louver
BODY STYLE: A=Air Supply S=Static
2
FIXTURE
WIDTH
CEILING TYPE:
G= Grid
(lay-in T bar)
F=Flanged
(overlap)
Z spline and plaster frame
T=Slot grid or
two-directional concealed
T
(see options)
16
NUMBER OF
CELLS:
16=4 rows of
4
LOUVER FINISH*:
L= Low
Iridescence Semi-specular (standard)
P= Low
Iridescence Specular
W=White Baked
Enamel
G= Champagne
Gold
S
SINGLE “V” REFLECTOR
2
LAMP
QUANTITY
LAMP TYPE/
FIXTURE LENGTH:
FT=Twin Tube T5
2U=1-5/8"U Lamp T8
(Nominal 48")
VOLTAGE:
120 or 277
OPTIONS:
Add appropriate suffix to catalog
no, ie: (RF)
BALLAST TYPE:
<20THD <10THD
1-2 Lamp Elec. TT5 SB
* IB*
(40 Watt)
1-2 Lamp Elec. T8 SO* HI*
(31 Watt)
LOL T8 Dimming PS LOL TT5 Dimming PB
*Instant Start Standard
Other dimming options. Consult factory.
Luminaire Efficacy Rating LER-54.7 Watts-68.8 BF-0.86
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 SECTION 2/Folio G51-38
Job Information Type:
DEEPCEL plus
DPA2G16LS2FT OR 2U
Page 2 of 2 2'x2' RECESSED FLUORESCENT, 3" DEEP, 16 CELL PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, 2 LAMP TWIN TUBE T5 OR 1 5/8"U LAMP T8