Lightolier Dorm Lyte User Manual

Wall Mounted Fluorescent Dorm Lyte
Page 1 of 2 6" Width, 48" Nominal Length
1 or 2 Lamp T5 or T8
• For dorms, nursing homes, assisted living, health care facilities, or other over bed or wall mounted applications.
• Up and downlight, 1 or 2 lamp.
• Separate lamp compartments for controlled uplight and downlight.
Unique co-extension. White opaque center. Frosted white front sections for subtle glow. Linear prisms to spread up/downlight.
• Only 3-7/8" deep, meets American With Disabilities Act for wall mounted fixtures.
• Concealed pull-action spring-loaded latches to retain lens.
• 20 gauge cold rolled steel post painted baked white enamel end caps.
• Nominal 4' length.
• Four-way pull switch, (120 volt only) optional.
• Optional low voltage electronic sequential switch for push button control of up/down lighting. UL 544 listed. Includes phone jack type receptacle.
Features Dimensions
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 4A/Folio I60-10
4/06
6" (152mm)
3-7/8 (95mm)
Up/Downlight
Uplight or Downlight
4"
(102mm)
6"
(152mm)
24"
(610mm)
47-15/16
(1218mm)
6" (152mm)
3-7/8 (95mm)
0.0 45.0 90.0 FLUX
0 465 465 465
5 479 455 455 44 15 531 425 420 126 25 581 375 368 190 35 615 311 301 237 45 630 241 228 261 55 623 168 153 254 65 589 108 95 235 75 548 55 48 203 85 504 14 10 172 90 496 12 0 95 514 32 13 184
105 558 77 55 223 115 598 132 107 257 125 623 195 170 278 135 630 261 237 278 145 615 326 304 252 155 581 384 365 201 165 531 425 412 128 175 470 446 442 43 180 448 448 448
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 4A/Folio I60-10
Job Information Type:
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF. Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture. SUFFIX: R. One per Ballast, SUFFIX: B. Electronic (Low Voltage) Sequential Switch: Switch factory mounted for Up and
Down Light operation from pillow switch. Includes phone jack type receptacle. SUFFIX: SW. Momentary Button Cordset: Traditional "Winged" Pendant design ESD protection to 15,000 volts. Heavy duty 7' cable with phone plug and security clip. Consult factory: Part number 7800W-7 CSP. (Button Cordset can only be used with SW Sequential Switch option)
4-Way Pull Switch: SUFFIX: 4P. Electrical Wiring Options: Consult factory.
Specifications
Materials: Chassis parts are die-formed code rolled steel. End Caps–20
gauge cold rolled steel. Refractor–1/8" thick DR acrylic, unique co-extrusion, white opaque center, linear prisms to spread up/down light.
Finish: exterior white baked acrylic enamel. End Caps and Cover–Post painted baked white enamel, 86% reflectance.
Phospate undercoating.
Wall Mounted Fluorescent Dorm Lyte
Page 2 of 2 6" Width, 48" Nominal Length
1 or 2 Lamp T5 or T8
Model No. DL4X232120SO
LER = FP - 58.6 IW - 53.1 BF - 0.88 Comparative yearly lighting energy cost per
1000 lumens = $4.10
Report Number: G2006054 Lamp: F32T8 Luminaire: Up/down Wall Mounted with
Two Color Co-extruded Lens
Ballast: B232
IUNVHP-B
Report is based on 2950 Lumens per lamp. Efficiency: 60.4% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg 180-Deg. Spacing Criteria: 1.9 1.1 1.1 Shielding Angles: 55 65 Luminous Length: 48.000 2.400 Height of Side 6.000 6.000
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 10652. 1310. 3855. 55 12396. 862. 3044. 65 014783. 540. 2384. 75 019419. 277. 1701. 85 032024. 73. 635.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01585452424038343332 02524743363331292725 03474136312825262321 04433631282421232018 05393227252118201715 06362823221816181513 07332621201614161412 08312318181512151210 09292116171311141199
10 27 19 15 15 12 10 13 10 88
ZONE LUMENS % LAMP % FIXT
00-030 359 6.1 10.1 00-040 596 10.1 16.7 00-060 1112 18.8 31.2 00-090 1723 29.2 48.3
90-120 664 11.3 18.6 90-130 942 16.0 26.4 90-150 1472 25.0 41.3 90-180 1843 31.2 51.7
00-180 3566 60.4 100.0
ZONAL LUMEN SUMMARY
Ordering Information
Explanation of Catalog Number. Example: DL4X232120SO
DL
Options:
Add appropriate suffix to catalog
no., ie: (GLR)
Dorm Lytel:
Wall Mounted
Fluorescent
Lamp
Quantity:
1=1 Lamp 2=2 Lamp
Ballast Type:
<20THD <10THD
1 or 2 Lamp 32W Elec. T8 SO * H
I *
1 or 2 Lamp 28W Elec. T5 –P
I
1 or 2 Lamp 28W Elec. T5 PG †† 1 or 2 Lamp 54W Elec. T5 PG ††
(Nominal 48")
LOL T8 Dimming PS* *Instant Start Standard
†Instant Start (120 or 277) ††Program Rapid Start (UNV only)
NOTE: For T8 UNV, you must use H
I Ballast Code.
Voltage:
120, 277 or UNV
UNV=120-277
Lamp Type: 32=32W T8 28=28W T5 54=54W T5
4
Fixture Length:
4=48"
X = Up/Down Light R = Independent
Up or Down Light . (2 lamp only)
Room Size: 12' x 10' x 8' Ceiling. Reflectance: 80-50-20 .80LLF Reading Area: 35-40fc
15 35 52 35 15
15 25 31 35 15
12 14 16 14 12
9 101010 9
88887
77777
1'
3'
5'
7'
9'
11'
1' 3' 5' 7' 9'
3'
5'
3'6"
Reading
Plane
35 to 40 fc reading plane (60° from horizontal)
reading position
Specifications (continued)
Electrical: Thermally protected class “P” ballast CBM approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
Loading...