Architectural Decorative Vetro Downlight D01
Page 1 of 3 Compact Fluorescent
3
1
C
A
B
Complete Fixture consists of Decorative Element, Trim-Kit + Frame-In Kit. Each sold seperately.
3 Piece Ordering System, Example: D4A01 + 8011CL + 4118VU
2
Decorative Element
Trim- Kit Frame-In Kit Lamping Dimensions
Catalog No.
D4A01
D6A01
D7A01
8011CL 4118VU Family
D4132VU Family
8021CL; 8031CL; 8091DCL
8052CL
8051CL
8022CL; 8037CL; 8097DCL
8056CL; 8096DCL
8056CL; 8096DCL
8056CL
S6132BU Family
6213HU Family
6218HU Family
S7142BU Family
7218HU Family
S7226HU Family
7126HU Family
Features
1. Decorative Element: Solid high temp, UV resistant composite with open
aperture. Interior diameter is frosted. Polished ex terior.
2. Aluminum Insert: Satin Aluminum ring is mechanically inser ted in
composite to create drama and intrigue in the element.
3. Die Cast Construction Ring: Exterior edge of construction ring is visible,
satin aluminum finish matches diameter of decorative element for a
flangeless appearance.
4. Fastener cover: Stamped aluminum cover ring provided on top of decorative
element to cover construction ring fasteners.
5. Mounting Frame Fasteners: Four #8-32 screws and 4 knurled die-cast
thumb screws secure construction ring to frame in kit.
6. Reflector: FLANGELESS TRIM REQUIRED. Specified separately. Use
Specular Clear (CL) finish for best performance and aesthetics
7. Frame-In Kit: Specified separately. See Trim Specification Sheet for
additional details.
B C
(1) 18W Triple Tube
(1) 26W or 32W Triple Tube
(1) 26W or 32W Triple Tube
(2) 13W Quad
(2) 18W Quad
(1) 26W, 32W or 42W Triple Tube
(2) 18W Quad Tube
(2) 26W Quad Tube
(1) 26W Quad Tube
A
3 3/4" 6" 1 3/4"
4 5/8" 7 1/2" 1 7/8"
5 1/2" 9" 2"
Mechanical
Decorative elements securely fastened to four mounting frame studs.
Labels
cULus (Damp Location)
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier is a Philips group brand
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • B1108
Architectural Decorative Vetro Downlight D01
Page 2 of 3 Compact Fluorescent
8021CL-D6AO1
Calculi te 6" Reces sed Vetro Dow nlight, Cat .# 8021CL/D6 A01
125
250
375
500
0°
Lumina nce Summar y - CD. / SQ. M.
An gle Mea n CD/SQ M
45 13825
55 4359
65 446 0
75 5694
85 13872
90°
60°
30°
32W G.E. B iax T/E Triple Tube (Low er Position).
Lumen R ating = 2200 L ms. Univers al Ballast #C2 642UNVBES
Candl epower Sum mary
Angle Mean C P LM S. A ngle Mean CP LMS.
0 459 90 20
5 44 8 44 95 17 15
10 4 89 100 3
15 526 146 105 2 2
20 524 110 2
25 487 22 3 115 2 2
30 426 120 2
35 356 2 22 125 2 2
40 274 130 2
45 178 13 8 135 2 1
50 8 5 140 2
55 45 48 145 2 1
60 3 9 150 2
65 34 34 155 2 1
70 31 160 2
75 27 29 165 2 1
80 24 170 2
85 22 24 175 2 0
90 20 180 2
Tested A ccording to I ES Procedu res. Test Dista nce Excee ds Five
Times t he Greates t Luminous Op ening of Luminai re.
Ceiling 8 0% 70% 50% 30% 10%
Wall 70 50 30 10 7 0 50 30 10 5 0 30 10 50 30 10 50 30 10 0
RCR Zona l Cavity Me thod - Effe ctive Floo r Reflecta nce = 20%
0 .5 0 .50 .50 .50 .49 .49 .4 9 .49 .46 .4 6 .46 .44 .4 4 .44 .42 .4 2 .42 .41
1 .4 7 .46 .44 .43 .46 .45 .4 3 .42 .42 .4 2 .41 .41 .4 0 .39 .39 .3 8 .38 .37
2 .4 4 .42 .40 .38 .43 .41 .3 9 .37 .39 .3 8 .36 .38 .3 6 .35 .36 .3 5 .34 .34
3 .41 .38 . 36 .34 .40 . 37 .35 .33 . 36 .34 .33 . 35 .33 .32 . 34 .33 .31 . 31
4 .3 9 .35 .33 .30 .38 .35 .3 2 .30 .34 . 31 .30 .33 . 31 .29 .32 .3 0 .29 .28
5 . 37 .33 .30 .28 .36 .32 .2 9 .27 .31 .2 9 .27 .30 .2 8 .27 .29 .2 8 .26 .26
6 .3 5 .30 .27 .25 .34 .30 .2 7 .25 .29 .2 6 .25 .28 .2 6 .24 .27 .2 6 .24 .23
7 . 32 .28 .25 .23 .32 .27 . 25 .23 .27 . 24 .22 .26 . 24 .22 .25 .2 3 .22 .21
Room C avity Rati o
8 .3 0 .26 .23 .21 .30 .25 .2 3 .21 .25 .2 2 .20 .24 .2 2 .20 .24 .2 2 .20 .19
9 . 28 .24 .21 .19 .28 .23 . 21 .19 .23 .2 0 .19 .22 .2 0 .18 .22 .2 0 .18 .18
10 .27 .22 .19 .17 . 26 .22 .19 .17 .21 .19 .17 .21 .18 .17 .20 .18 .17 .16
Deter mined In Acc ordance Wi th Current I ES Published Pr ocedures
Zonal L umens and P ercenta ges
Zone Lumen s % L amp %Lu minaire
0-3 0 413 18.77 44. 29
0-4 0 634 2 8.84 68. 05
0-6 0 820 37.32 88. 03
0-9 0 907 41.26 97.3 5
40- 90 273 12.42 29. 30
60- 90 86 3.95 9.31
90-180 24 1.12 2. 65
0-180 9 32 42. 39 10 0.00
** Efc iency = 42.4% **
Coef ficient s of Utiliz ation
Luminai re Input Wat ts = 33.0
Cert ied test re port# 34 94FR
Compu ted by LSI pr ogram **TEST-L ITE**
SC = 1.0
Prep ared For:
Light olier
Fall River, MA
8031CL-D6AO1
100
250
375
500
0°
Calculi te 6" Dia. Rece ssed Horiz ontal Vetro D ownlight,
90°
32W Syl vania Dulux T/E Triple Tub e. Lumen Ratin g = 2400 LMS.
Angle Along 22.5 45 67.5 Across LMS
0 408 408 408 408 408
60°
5 410 418 423 422 420 40
10 43 2 445 452 440 436
15 44 5 446 439 429 431 123
20 4 34 427 416 409 413
25 419 3 93 393 417 416 187
30 3 84 388 381 391 388
35 3 26 351 383 396 393 224
40 25 2 266 299 322 323
45 19 3 182 174 172 171 150
50 15 0 141 127 111 111
55 87 79 73 72 73 72
60 41 42 43 44 4 4
30°
65 36 37 37 38 38 3 8
70 32 33 3 3 34 3 4
75 28 28 29 30 30 31
80 25 26 27 27 26
85 23 24 24 25 24 26
90 20 21 21 21 21
Tested A ccording to I ES Procedu res. Test Dista nce Excee ds Five
Times t he Greates t Luminous Op ening of Luminai re.
Cat.# 8 031CL/D6A 01
Unive rsal Ballast # C2642UNVB ES(#1)
Candl epower Su mmary
Coef ficient s of Utiliz ation
Ceiling 80% 70% 50% 30% 10%
Wall 70 50 3 0 10 70 50 3 0 10 50 30 10 50 30 10 50 30 10 0
RCR Zonal C avity Met hod - Effec tive Floor Re flectan ce = 20%
0 .4 4 .44 .44 .44 .43 .43 .4 3 .43 .41 . 41 .41 .40 .40 .4 0 .38 .38 . 38 .37
1 .41 .40 . 39 .37 .40 . 39 .38 .37 .37 .37 .36 .36 .35 .35 .35 .34 .3 4 .33
2 .3 9 .36 .34 .33 .38 .36 .3 4 .32 .34 .3 3 .32 .33 .3 2 .31 .32 . 31 .30 .30
3 .3 6 .33 .31 .29 .35 .32 .3 0 .29 .31 .3 0 .28 .31 .2 9 .28 .30 .2 8 .27 .27
4 .3 4 .30 .28 .26 .33 .30 .2 8 .26 .29 .2 7 .25 .28 .2 6 .25 .27 .2 6 .25 .24
5 . 32 .28 .25 .23 .31 .27 . 25 .23 .27 . 24 .23 .26 . 24 .23 .25 . 24 .22 .22
6 .3 0 .26 .23 .21 .29 .25 .2 3 .21 .25 .2 2 .21 .24 .2 2 .20 .23 .2 2 .20 .20
7 . 27 .23 .21 .19 .27 .23 .2 0 .19 .22 .2 0 .18 .22 .2 0 .18 .22 .2 0 .18 .18
Room C avity Rati o
8 . 26 .21 .19 .17 .25 .21 .19 .17 .21 .18 .17 .20 .18 .17 .20 .18 .16 .16
9 . 24 .20 .17 .15 .23 .19 .17 .15 .19 .17 .15 .19 .16 .15 .18 .16 .15 .14
10 .22 .18 .15 .14 .2 2 .18 .15 .13 .17 .15 .13 .17 .15 .13 .17 .15 .13 .13
Deter mined In Acc ordance Wi th Current I ES Published Pr ocedures
Zonal L umens and P ercenta ges
Zone Lumen s % L amp %Luminaire
0-3 0 350 14.60 39.31
0-4 0 574 23.92 64.42
0-6 0 796 33.19 89.37
0-9 0 891 37.14 100 .00
40- 90 317 13.22 35.58
60- 90 94 3.95 10.63
90-180 0 .00 .0 0
0-180 891 37.14 100.0 0
** Efc iency = 37.1% **
Luminai re Input Wat ts = 36.0
Cert ied test re port no. 35 33FR
Compu ted by LSI pr ogram **TEST-L ITE**
SC(Al ong) = 1.3, SC(Ac ross) = 1.5
Prep ared For:
Light olier
Fall River, MA
Lightolier is a Philips group brand
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • B1108