Lightolier CXS 2x2 User Manual

Meets requirements for Federal Standard
209E Class 10,000 & 100,000 Clean Room tested by Independent Lab.
UL and ULc Listed for wet or damp locations for covered ceiling use.
Fits 15/16" to 1" wide face grid ceiling sys­tems or flanged for drywall type ceilings. Contractor responsible for sealing fixture to ceiling.
Full perimeter gasketing (closed cell Neoprene) between door frame and lens, between housing and door frame.
Ends sealed to body.
.125 pattern 12 lens installed smooth side
down.
Door frame is post painted, baked acrylic enamel.
Hemmed over side rails for maximum safety.
Spring loaded rooster head latches.
18 gauge steel hinges.
Flat and regressed aluminum doors available.
CXS SERIES 2x2
CLEANGUARD CLASS 10,000 CLEAN ROOM
RECESSED FLUORESCENT 2 OR 3 LAMP, T8, 1-5/8" U LAMP, OR TT5
MOUNTING METHODS DIMENSIONS
exposed T-grid ceiling.
G
(with flat aluminum frame)
24"
drywall kit (see options)
Type “G”
FIxture
Ceiling Opening
24-5/16" x 24-5/16"
1/4" max.
1-1/2" max.
15/16" or 1"
Support
(by others)
Drywall Kit
(See Options)
Drywall
(by others)
15/16"
plaster ceiling/flanged.
F
Plaster
Opening
24-1/8"
24-11/16"
gasketing detail
Fixture
Lens
1-1/8" min. 3-3/4" max.
13/16"
Gasketing (Close Cell Neoprene)
Door Frame
5"
(127mm)
FIXTURE TYPE VOLTS
5" (127mm)
24" (610mm)
23-7/8"
(606mm)
15-11/16"
(398mm)
2"x2-1/2" access plate with two K.O.s (7/8" dia.)
JOB INFORMATION:
SECTION 6/Folio N40-10
CXS SERIES 2x2
CLEANGUARD CLASS 10,000 CLEAN ROOM
RECESSED FLUORESCENT
PHOTOMETRY MODEL NO. CXS2GFSVI26U120SO
CXS2GFSVI26U120SO
LER = FL - 56.0 IW - 53.7 BF - 0.87 Comparative yearly lighting energy cost per 1000 lumens = $4.24
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20 RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1696663 626058 595856 2635854 545148 525047 3575146 484441 464340 4534540 433835 413834 5484135 383430 373330 6453731 353027 343026 7423328 322724 312723 8393025 292421 282421
room cavity ratio
9362823 272219 262219
10 34 26 21 25 20 17 24 20 17
ORDERING INFORMATION
Explanation of Catalog Number. Example: CXS2GFSVI26U120SOGLR
CX
CLEANGUARD
WET
LOCATION
Class 10,000
or
100,000
Clean Room
OPTIONS/ACCESSORIES PLASTER FRAME: Catalog Number PF24.
CONTINUOUS ROW INSTALLATION: For F
type fixtures, half width flanges are required between fixtures. Order Catalog Number: S2FCTRIM (each joint).
S 2 VI
STATIC
FIXTURE
WIDTH
CEILING TYPE: G= Grid (lay-in T bar) F=Flanged (overlap) Z spline
and plaster frame
LENS FRAME: FS= Flat steel frame RA=Regressed
aluminum frame
FA=Flat aluminum
frame
LENS/SHIELDING TYPE:
VI=(virgin acrylic) .125
standard. For options
consult factory. Smooth side of
lens towards room.
FUSING: Internal fast-blow fusing.
SUFFIX: GLR. Internal slow-blow fusing.
SUFFIX: GMF. ELECTRICAL/WIRING OPTIONS: Consult factory.
SPECIFICATIONS:
MATERIALS: Chassis parts are die-formed code gauge cold rolled steel.
Housing with side rails hemmed over and housing ends turned-in for safe handling. FINISH: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. LENSES: VI (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the panel edge, .125" nominal thickness (similar to pattern 12). ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and ULc Listed.
LAMP
QUANTITY:
2=2 Lamp 3=3 Lamp
LAMP/
FIXTURE LENGTH: 2U=T8, 1-5/8" U Lamp 17=T8, 2' Lamp 6U=6" U Lamp (T8) FT=Twin Tube T5
(Nominal 24")
Other dimming options. Consult factory.
VOLTAGE:
120 or 277
BALLAST TYPE:
1-1 & 1-2 Lamp Elec. T8 SO* H 1-3 Lamp Elec. T8 O3* H3*
1-1 & 1-2 Lamp Elec. TT5 SB*
(40 Watt)
1-3 Lamp Elec. TT5 X3* I3* LOL T8 Dimming PS* - LOL TT5 Dimming PB* -
*Instant Start Standard
OPTIONS:
Add appropriate suffix
to catalog no., ie: (GLR)
20THD <10THD
<
I*
IB*
We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
TECHNICAL INFORMATION • (978) 657-7600 631 AIRPORT ROAD, FALL RIVER, MA 02720 • (508) 679-8131 C.F.I. DIVISION OF CANLYTE, INC.
A Genlyte Thomas Company
525 EDUCATION ROAD, CORNWALL, ONTARIO CANADA K6H 6C7 • (613) 938-6221
PRINTED IN USA 3/02