Lightolier COL, EOL User Manual

Page 1 of 2 Type 4 Distribution, Integral 35-Watt Emergency Xenarc Lamp
The COL Series is designed to provide normal and outdoor egress lighting in a single fixture.
17”
(43.2cm)
9.25”
(23.5cm)
7.25”
(18.4cm)
How to Specify 100w HPS or 100w MH luminaire with/without 35w Xenarc® lamp:
COL
SERIES
COL = Forward Throw Cutoff Luminaire
AC LAMP TYPE
1H = 100-Watt, High-Pressure Sodium Lamp 1M = 100-Watt, Metal Halide Lamp
EMERGENCY FUNCTION
Blank = AC Fixture, No Emergency Lamp EM = 35-Watt, Instant Strike Xenarc® Lamp
1
BZ
HOUSING COLOR
BZ = Dark Bronze
2
How to Specify 100w HPS or 100w MH luminaire with 35w Xenarc® lamp and remote C3250LWDLTD emergency module:
EOL
SERIES
EOL = Forward Throw Cutoff Luminaire
AC LAMP, 35W AND C3 MODULE
HRW(B)= 100-watt High Pressure Sodium lamp & White (Black) C3 EM Module MRW(B)= 100-watt Metal Halide lamp & White (Black) C3 EM Module 3
3
BZ
HOUSING COLOR
BZ = Dark Bronze
2
How to Specify 100w HPS or 100w MH luminaire with 35w Xenarc® lamp and remote E4250LWTD emergency module:
EOL
SERIES
EOL = Forward Throw Cutoff Luminaire
AC LAMP, 35W AND E4 MODULE
HSW(B) = 100-watt High Pressure Sodium lamp & White (Black) E4 EM Module MSW(B)= 100-watt Metal Halide lamp & White (Black) E4 EM Module 4
4
BZ
HOUSING COLOR
BZ = Dark Bronze
NOTES:
1) Requires a remote emergency power source of 12 VDC and at least 35-watts and TD to cover re-strike period.
2
2) Custom Colors available, consult factory.
3) See C3 sheet for product specifications
4) See E4 sheet for product specifications.
Features
1. Illumination: Normal illumination is provided by one 100-watt, high-
pressure sodium lamp or one 100-watt, metal halide lamp, combined with a polished specular aluminum reflector with Type 4 distribution. Normally on illumination may be switched or photocell controlled. Emergency illumination is accomplished with a 35-watt, instant strike Xenarc® lamp, powered from a remote emergency battery unit (sold separately).
2. Housing: All housing components are of premium die-cast aluminum
construction with a durable dark bronze powder coat finish. Stainless steel torx head T25 tamperproof hardware included.
3. Electronics: AC Only - HX/HPF core/coil HID ballast, spring loaded
4KV pulse rated HID socket, medium base.
Emergency Operation - 35-watt, instant strike Xenarc lamp (requires
a remote emergency power source of 12 VDC, 35-watts minimum)
4. Operating Temperature Range - Wet location: -40°F (-40°C) to
104°F (40°C)
5. Recommended Emergency Battery Units (sold separately) -
Indoor/Outdoor** Recessed Ceiling Mount - C3250LWDLTD
Indoor Surface Mount - E4250LWTD
* The COL Series emergency lamp requires a remote 12 VDC power source. ** The C3250LWDLTD may be used outdoors in locations where the product is not directly exposed to the elements.
Lightolier is a Philips group brand
6. Electrical Specifications: 120/208/240/277 VAC, 60 HZ, multi-tap input wiring; 130-watts power consumption
7. Warranty: Five-year warranty (excludes lamps.)
Code Compliance
Wet location listed
ETL listed to UL 924 standards ETL listed to UL 1598 standards ETL listed to CSA C22.2 No 141-02 standards ETL listed to CSA C22.2 No 250.0-04 standards
Job Information Type:
Job Name:
Cat. No.:
Lamp(s): Notes:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • C0608
Page 2 of 2 Type 4 Distribution, Integral 35-Watt Emergency Xenarc Lamp
Illumination
I.E.S. format photometric data files are available for use with most lighting layout application software.
Photometric Data*
Metal Halide in AC Mode, 15’ AFF
Metal Halide in Emergency Mode, 15’ AFF
Average initial footcandles at floor = 1.03
Maximum initial footcandles at floor = 2.4 Minimum initial footcandles at floor = 0.1 Maximum to minimum ratio = 24.00
Average initial footcandles at floor = 1.41 Minimum initial footcandles at floor = 0.2 Maximum initial footcandles at floor = 4.9 Maximum to minimum ratio = 24.50
HPS in AC Mode, 15’ AFF
HPS in Emergency Mode, 15’ AFF
Average initial footcandles at floor = 1.06
Maximum initial footcandles at floor = 2.4 Minimum initial footcandles at floor = 0.1 Maximum to minimum ratio = 24.00
Average initial footcandles at floor = 1.55 Minimum initial footcandles at floor = 0.2 Maximum initial footcandles at floor = 5.9 Maximum to minimum ratio = 29.50
*The optics layout is intended to be used as reference only. Standard reflectances used were 0/50/20. Lightolier is not responsible for site specific conditions that may alter the results.
Xenarc® is a registered trademark of Osram Sylvania
Lightolier is a Philips group brand
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • C0608