Lightolier COIL CORD CLAMP-ON MONOPOINT Instructions Manual

Page 1
v
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
INSTRUCTION SHEET NO. ThisfixtureisintendedforinstallationinaccordancewiththeNationalElectricalCodeandlocalregulations. Toassure
full compliance with local codes and regulations, checkwith your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructionsfor maintenance reference.
A1294
Page 1 of2
INSTRUCTIONS FOR ATTACHING COIL CORD CLAMP-ON MONOPOINT
FORUSE WITH LIGHTOLIER TRACK FIXTURES ONLY
ATTACHING COILEDCORDCLAMP-ON MONOPOINT
TIGHTENING KNOB
TO PIPE
ORPIPESTRUCTURE
This CLAMP is designed to mount on round pipe, pipe structures,
PIPE OUTSlOE
or round supports. Secure the CLAMP to structure by tightening
DIAMETER 5/8” TO 2“
the TIGHTENING KNOB and the body allowed to face downward
RECOMMENCED
CLAMP
to minimize
force required to support I_ytespots (Fig. 1). A (3) prong 120V, 60 Hz, grounded receptacle is required to energize the unit,
MONOPOINT
AllACHING LYTESPOTWITH “T’ ADAPTORTO COIL
AOAPTOR
CORDCLAMP
FIG. 1
1.Position LEVER as shown in Fig. 2,
2. Align BEAD on MONOPOINT ADAPTOR with GROOVE in “T”
adaptor, see Fig. 2 (If BEAD is NOT aligned, a potential hazard may result). Rotate LEVER 90 degrees to secure Lytespot.
3. To remove !_ytespot: Hold fixture and rotate LEVER 90 degrees
(Fig. 3).
CAUTION- INJURY TO PERSONS AND DAMAGE TO
THE LAMP AND/OR MOUNTING SURFACE MAY RESULT IF THE LAMP IS PULLED FROM THE SURFACE. TO
co
REDUCE THE LIKELIHOOD OF SUCH INJURY OR DAMAGE, MOUNT ONLY ON A SURFACE THAT IS MECHANICALLY SOUND.
GAS
FIG.
2
GROUNO
,,
u
FIG. 4
FIG. 3
1-I
C3H TC> L IE R“
E~~~~f~;,N~~
‘T” ADAPTOR(lDIA. SHAIT) JSEDWITHCAT.NO.S6435&
BOXADAPTOR
7599
z
E
NOTE:
Not designed to work with
COIL CORD CLAMP-ON MONOPOINT
Page 2
INSTRUCTIONSHEETNO.
1S:6196
INSTRUCTIONS FOR AITACHING COIL CORD CLAMP-ON
MONOPOINT
(Cent’d)
FORUSEWITH LIGHTOLIERTRACKFIXTURESONLY
A1294
Page 2 of 2
INSTRUCTIONS FOR ATTACHING LYTESPOT WITH SQUAT ADAPTOR TO COIL CORD CLAMP 1, Insertthe SQUATADAPTERinto the MONOPOINTADAPTOR.The LOCKING LEVER must be on the same side as the BEAD located on the
MONOPOINT ADAPTOR (See Fig. 5). Rotate the SQUAT ADAPTOR 90 degrees clockwise until LOCKING LEVER locks into place (See Fig. 5, 6 & 7).
2. To remove, depress LOCKING LEVER and rotate SQUAT ADAPTOR 90 degrees counterclockwise.
I CAUTION- SUPPORT THE MONOPOINT ADAPTOR WHENEVER MANIPULATING THE FIXTURE. I
MONOPOINT
ADAPTOR
LOCKING
SQUAT
LEVER
ADAPTOR
L
*
1
BEAD
&
*
FIG.5
FIG.6
FIG.7
INSTRUCTIONS FOR AllACHING LOW VOLTAGE TO COIL CORD CLAMP
1.Insert the LOW VOLTAGE ADAPTOR into the MONOPOINT ADAPTOR. The LOCKING LEVER must be on the same side as
on the MONOPOINT ADAPTOR (See Fig. 8). Rotate the LOW VOLTAGE ADAPTOR 90 degrees clockwise to secure fixture electrical connection (See Fig. 8,9 & 10).
2, To remove, rotate LOW VOLTAGE ADAPTOR 90 degrees counterclockwise.
I CAUTION- SUPPORT THE MONOPOINT ADAPTOR WHENEVER MANIPULATING THE FIXTURE. I
w
MONOPOINT
RFAD —
ADAPTOR
“-”--::AGE
LOCKING ~ LEVER
/
ADAPTOR
FIG.8
FIG.9
%
FIG. 10
the BEAD located and make
Loading...