Lightolier CFH2GPF217, CFH2GPF317 User Manual

Mounting Methods Dimensions
Features
• Direct/indirect lamp shield appearance with soft contoured interior.
• Perforated mesh lamp shield with white acrylic overlay.
• Contoured body and ends.
• Air return models meet UL 1598, Paragraph 9.2.2.5 requirements.
• 61.7% efficient (2 lamp T8).
• 55.9% efficient (3 lamp T8).
• Only 5" deep.
• Tension bars secure ends to body.
Same fixture fits both G and T ceiling.
• Fits flush to face of slot grid (T) ceiling.
• Static models have injection molded light stop at basket ends.
• Air return standard (meets UL requirements).
• Perforated lamp shield hinges from either side.
• Can be continuous row mounted.
• Built-in earthquake clips.
• Construction to meet NYC Code or Chicago Plenum requirements is available.
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
11/05
Coffaire II Recessed Fluorescent CFH2GPF217 or 317
Page 1 of 2 Direct/Indirect – 2' x 2' with Perforated Basket
Air Return/Static, 2 Lamp or 3 Lamp, T8
24" (610mm)
5"
(127mm)
2-1/2"
(64mm)
2" x 2-1/2" Access Plate with (2) 7/8" dia. K.O.
24" (610mm)
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section 5/Folio M15-34
lamp shield hinges either side
exposed t-grid ceiling
exposed slot t-grid ceiling
Acoustical material by others
Exposed T-bar by others
1-1/2" max.
Acoustical material by others
15/16"
24"
1-7/8" max.
Exposed T-bar by others
9/16"
24"
built-in earthquake clips
light stop-static models only
Coffaire II Recessed Fluorescent CFH2GPF217 or 317
Page 2 of 2 Direct/Indirect – 2' x 2' with Perforated Basket
Air Return/Static, 2 Lamp or 3 Lamp, T8
Job Information Type:
Ordering Information
Explanation of Catalog Number. Example: CFH2GPF217120SO
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X2 and CF2FK SPACER. Electrical Wiring Options: Consult factory. Chicago Plenum: SUFFIX: C.
Specifications
Performance: In an installation of 2 lamp 40W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .64. To reduce glare the average brightness at 65° shall not exceed 1815 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 73.2%.
Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic
overlay. Finish: Chassis exterior – baked white polyester enamel. Cavity – baked flat white polyester enamel. Reflector – baked flat white polyester enamel, mini-
Specifications (continued)
mum 86% reflectance. Phosphate undercoating. Lamp Shield – baked flat white acrylic enamel. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
Options:
Add appropriate suffix to catalog
no., ie: (GLR)
Coffaire II:
Direct/
Indirect:
Recessed
with Perforated
Mesh Shield
Body Style:
H = Air Return S = Static
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
P
Perforated
Lamp
Shield
17
Lamp:
(By Others)
17=T8
(Nominal 24")
F
Flat
White
Reflector
Lamp
Quantity
2=2 Lamp 3=3 Lamp
Ballast Type:
<20THD <10THD
1 or 2 Lamp Elec. T8 SO * H
I *
1-3 Lamp Elec. T8 O3 * H3 * LOL Dimming T8 PS*
*Instant Start Standard Other dimming options. Consult factory.
NOTE: For T8 UNV, you must use H
I
,H3, Ballast Code.
Model No. CFH2GPF217120SO
LER = FP - 50.2 IW - 30.08 BF - 0.93 Comparative yearly lighting energy cost per
1000 lumens = $4.78
Report Number: G2004248 Catalog Number: CFH2GPF217120SO Lamps: F017/41K Luminaire: Coffaire 2'x2' with perforated
basket Ballast: Triad C240SI120 Report is based on 1350 Lumens per lamp.
Efficiency: 61.7% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 55 65 Plane: 0-Deg 90-Deg Luminous Length: 22.920 22.920
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1443. 1668. 1856. 55 1301. 1656. 1928. 65 1089. 1605. 1815. 75 889. 1037. 1219. 85 508. 541. 575.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01676462605857585655 02615652534947514846 03564944464239454138 04514338413733403633 05473933373229353128 06433529332825322825 07403226302522292522 08372923272320272319 09352621252118252018
10 32 24 19 23 19 16 23 19 16
ZONE LUMENS % LAMP % FIXT
00-030 446 16.5 26.8 00-040 736 27.3 44.2 00-060 1327 49.1 79.7 00-090 1665 61.7 100.0
90-180 0000 0.0 000.0
00-180 1665 61.7 100.0
ZONAL LUMEN SUMMARY
Model No. CFH2GPF317120O3
LER = FP - 48.7 IW - 46.5 BF - 1.00 Comparative yearly lighting energy cost per
1000 lumens = $0.00
Report Number: G2004249 Catalog Number: CFH2GPF317120O3 Lamps: F017/41K Luminaire: Coffaire with perforated
basket Ballast: Triad B332I120 Report is based on 1350 Lumens per lamp.
Efficiency: 55.9% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 55 65 Plane: 0-Deg 90-Deg Luminous Length: 22.920 22.920
0.0 45.0 90.0 FLUX
0 800 800 800
5 794 796 798 76
15 754 766 780 217
25 684 712 741 329
35 591 638 682 399
45 476 544 600 417
55 346 431 493 380
65 208 300 338 283
75 103 133 147 137
85 19 22 23 27
90 000
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1985. 2269. 2503. 55 1779. 2216. 2535. 65 1452. 2094. 2359. 75 1174. 1516. 1675. 85 643. 745. 778.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01615856555351535150 02565147484542464442 03514540423936413835 04464035373330363330 05433530342926322923 06393227302623292623 07362924272320272320 08342622252118242118 09322420231916231916
10 30 22 18 21 17 15 21 17 15
ZONE LUMENS % LAMP % FIXT
00-030 621 15.3 27.4 00-040 1020 25.2 45.1 00-060 1817 44.9 80.3 00-090 2264 55.9 100.0
90-180 0000 00.0 000.0
00-180 2264 55.9 100.0
ZONAL LUMEN SUMMARY
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section 5/Folio M15-34
Voltage:
120, 277 or
UNV=120-277
0.0 45.0 90.0 FLUX
0 572 572 572
5 569 570 570 54
15 541 550 560 155
25 492 515 537 237
35 426 465 500 290
45 346 400 445 307
55 253 322 375 283
65 156 230 260 215
75 78 91 107 104
85 15 16 17 20
90 000
CF
Standard Coffaire II
CY
For NYC Code – I.B.E.W. Manufactured
C3
For NYC Code –Local 3 Manufactured
Loading...