Lightolier CFH1GPF User Manual

Features
• Direct/indirect lamp shield appearance with soft contoured interior.
• Perforated mesh lamp shield with white acrylic overlay.
• 52.1% efficient (2 lamp T8).
• 55.7% efficient (2 lamp T5).
• Only 5-1/2" deep.
Same fixture fits both G and T ceiling types.
• Air return standard (meets UL requirements).
• Lamp shield hinges from either side.
• Can be continuous row mounted.
• Wiring access plate standard.
• 2 earthquake clips standard.
• Housing is 20 gauge steel, meets NYC Code requirements.
• Construction to meet Chicago Plenum requirements is available.
Mounting Methods Dimensions
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
9/05
Coffaire Recessed Fluorescent CFH1GPF
Page 1 of 2 Direct/Indirect – 1' x 4' with New Perforated Basket
Air Return/Static, 1 Lamp or 2 Lamp T8 or T5
7/8" Dia. K.O.
2-1/4"
(57mm)
1-1/2" x 1-1/2"
Access Plate
With 7/8" dia. K.O.
2-1/4"
(57mm)
48" (1219mm)
5-1/2"
(140mm)
12" (305mm)
Features
air return flow
lamp shield hinges either side
exposed t-grid ceiling
exposed slot t-grid ceiling
Acoustical material by others
Exposed T-bar by others
1-1/2" max.
Acoustical material by others
15/16"
24"
1-7/8" max.
Exposed T-bar by others
9/16"
24"
hold-down clips
Patent number 6,746,325
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section 5/Folio M15-20
Ordering Information
Explanation of Catalog Number. Example: CFH1GPF232120SOGLR
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK91X4 and CF4FK SPACER. Electrical Wiring Options: Consult factory.
Specifications
Performance: In an installation of 2 lamp 32W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .55. To reduce glare the average brightness at 65° shall not exceed 2454 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 70.4%.
Materials: Chassis parts are die-formed 20 gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic
overlay. Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Reflector – baked flat white acrylic enamel, minimum 86% reflectance. Phosphate undercoating. Lamp Shield – baked flat white acrylic enamel.
Specifications (continued)
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
CF
Options:
Add appropriate suffix to catalog
no., ie: (GLR)
Coffaire:
Direct/
Indirect:
Recessed
with Perforated
Mesh Shield
Body Style:
H = Air Return S = Static
1
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
P
Perforated
Lamp
Shield
Lamp:
(By Others)
32 =T8 28 =T5 54 = T5HO
(Nominal 48")
F
White
Reflector
Lamp
Quantity
1 = 1 Lamp 2 = 2 Lamp
Ballast Type:
<20THD <10THD
1 & 2 Lamp Elec. T8 SO* H
I *
1-2 Lamp 28W Elec. T5 –P
I
1-2 Lamp 28W Elec. T5 PG †† 1-2 Lamp 54W Elec. T5 PG ††
Linear T5 Instant Start WA
less than 10THD,
57.5 Input Watts,
0.93 Ballast Factor
LOL Dimming T8 PS
*Instant Start Standard†Instant Start (120V or 277V only)
††Program Rapid Start (UNV only) Other dimming options. Consult factory.
NOTE: For T8 UNV, you must use H
I
Ballast Code.
CN
For Local 3
Manufacturing
For Local 3 Manufacturing, substitute for . Example: CNH1GPF232120SOGLR.
.
CN CF
0.0 45.0 90.0 FLUX
0 1157 1157 1157
5 1147 1148 1153 109
15 1096 1095 1100 309
25 1004 998 995 460
35 877 858 854 539
45 720 692 696 540
55 535 514 511 464
65 343 330 341 333
75 172 168 165 175
85 27 33 34 39
90 000
Coffaire Recessed Fluorescent CFH1GPF
Page 2 of 2 Direct/Indirect – 1' x 4' with New Perforated Basket
Air Return/Static, 1 Lamp or 2 Lamp T8 or T5
Model No. CFH1GPF232120SO
LER = FP - 38.0 IW - 67.7 BF - 0.87 Comparative yearly lighting energy cost per
1000 lumens = $6.32
Report Number: G2004063 Catalog Number: CFH1GPF232120SO Lamps: F32/T8 TL841 Luminaire: CFH 1' x 4' with perforated
basket Ballast: Triad B332I120 Report is based on 2850 Lumens per lamp.
Efficiency: 52.1% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.920 10.920
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 3079. 2959. 2977. 55 2821. 2710. 2694. 65 2454. 2361. 2440. 75 2010. 1963. 1928. 85 0937. 1145. 1180.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01575552515048494847 02524844454240434139 03474238403634383633 04443733353229343129 05403429322825312725 06373026292522282522 07342723262220262219 08322521242018232017 09302319221816221816
10 28 21 17 21 17 14 20 17 14
ZONE LUMENS % LAMP % FIXT
00-030 0879 15.4 29.6 00-040 1418 24.9 47.8 00-060 2421 42.5 81.6 00-090 2968 52.1 100.0
90-180 0000 0.0 000.0
00-180 2968 52.1 100.0
ZONAL LUMEN SUMMARY
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section 5/Folio M15-20
Voltage:
120, 277 or
UNV=120-277
0.0 45.0 90.0 FLUX
0 1076 1076 1076
5 1065 1069 1075 102
15 1018 1025 1031 289
25 935 939 944 433
35 820 819 834 516
45 677 680 699 528
55 510 523 513 460
65 333 335 346 336
75 173 178 179 185
85 31 44 46 49
90 000
Model No. CFH1GPF228120WA
LER = FP - 47.5 IW - 57 BF - 0.93 Comparative yearly lighting energy cost per
1000 lumens = $5.05
Report Number: G2005196 Catalog Number: CFH1GPF228120WA Lamps: FP28/835/PM ECO Luminaire: CFH 1' x 4' with perforated
basket Ballast: WA Energy Saver System Report is based on 2600 Lumens per lamp.
Efficiency: 55.7% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.920 10.920
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2895. 2908. 2989. 55 2689. 2757. 2705. 65 2383. 2397. 2476. 75 2021. 2080. 2091. 85 01076. 1527. 1596.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01615856545351525150 02555147484542464441 03504540423936413835 04464035373430363330 05433530343026332926 06393227302623292623 07362924282421272320 08342522252118252118 09322420231917231916
10 30 22 18 22 18 15 21 17 15
ZONE LUMENS % LAMP % FIXT
00-030 0824 15.9 28.4 00-040 1340 25.8 46.2 00-060 2328 44.8 80.3 00-090 2898 55.7 100.0
90-180 0000 0.0 000.0
00-180 2898 55.7 100.0
ZONAL LUMEN SUMMARY