Lightolier CFA2GPF217, CFA2GPF317 User Manual

Coffaire II Recessed Fluorescent CFA2GPF217 or 317
Page 1 of 2 Direct/Indirect – 2' x 2' with Perforated Basket
Features
• Direct/indirect lamp shield appearance with soft contoured interior.
• Perforated mesh lamp shield with white acrylic overlay.
• Contoured body and ends.
• Air supply and return.
• Air return slots located above lamp shield.
• Air return models meet UL 1598, Paragraph 9.2.2.5 requirements.
• Spacing to mounting ratio 1.4 (2 lamp).
• Spacing to mounting ratio 1.3 (3 lamp).
• Only 5" deep.
• Tension screws secure ends to body.
• Perforated lamp shield hinges from either side.
• Can be continuous row mounted.
• Built-in earthquake clips.
• Ballast accessible from room side.
• Optional supply air slot cover.
• Meets NYC Code.
• Construction to meet Chicago Plenum requirements is available.
Mounting Methods Dimensions
Air Supply and Return, 2 Lamp or 3 Lamp, T8
24"
exposed t-grid ceiling
lamp shield hinges either side
Exposed T-bar by others
1-1/2" max.
15/16"
Acoustical material by others
built-in earthquake clips
5"
(127mm)
24" (610mm)
2-1/2"
(64mm)
2" x 2-1/2" Access Plate with 7/8" dia. K.O.
24" (610mm)
Job Information Type:
Job Name:
Cat. No.:
05/07
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company
Section 5/Folio M15-36
Coffaire II Recessed Fluorescent CFA2GPF217 or 317
Page 2 of 2 Direct/Indirect – 2' x 2' with Perforated Basket
Air Supply and Return, 2 Lamp or 3 Lamp, T8
Model No. CFA2GPF217120SO
LER = FP - 50.2 IW - 30.08 BF - 0.93 Comparative yearly lighting energy cost per
1000 lumens = $4.78
Report Number: G2004248 Catalog Number: CFA2GPF217120SO Lamps: F017/41K Luminaire: Coffaire 2'x2' with perforated
basket Ballast: Triad C240SI120 Report is based on 1350 Lumens per lamp.
Efficiency: 61.7% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 55 65 Plane: 0-Deg 90-Deg Luminous Length: 22.920 22.920
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 67 64 62 60 58 57 58 56 55 02 61 56 52 53 49 47 51 48 46 03 56 49 44 46 42 39 45 41 38 04 51 43 38 41 37 33 40 36 33 05 47 39 33 37 32 29 35 31 28 06 43 35 29 33 28 25 32 28 25 07 40 32 26 30 25 22 29 25 22 08 37 29 23 27 23 20 27 23 19 09 35 26 21 25 21 18 25 20 18
10 32 24 19 23 19 16 23 19 16
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1443. 1668. 1856. 55 1301. 1656. 1928. 65 1089. 1605. 1815. 75 889. 1037. 1219. 85 508. 541. 575.
0
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 572 572 572
5 569 570 570 54
15 541 550 560 155
25 492 515 537 237
35 426 465 500 290
45 346 400 445 307
55 253 322 375 283
65 156 230 260 215
75 78 91 107 104
85 15 16 17 20
90 000
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 446 16.5 26.8 00-040 736 27.3 44.2 00-060 1327 49.1 79.7 00-090 1665 61.7 100.0
90-180 0000 0.0 000.0
00-180 1665 61.7 100.0
0
Model No. CFA2GPF317120O3
LER = FP - 48.7 IW - 46.5 BF - 1.00 Comparative yearly lighting energy cost per
1000 lumens = $0.00
Report Number: G2004249 Catalog Number: CFA2GPF317120O3 Lamps: F017/41K Luminaire: Coffaire with perforated
basket Ballast: Triad B332I120 Report is based on 1350 Lumens per lamp.
Efficiency: 55.9% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 55 65 Plane: 0-Deg 90-Deg Luminous Length: 22.920 22.920
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 61 58 56 55 53 51 53 51 50 02 56 51 47 48 45 42 46 44 42 03 51 45 40 42 39 36 41 38 35 04 46 40 35 37 33 30 36 33 30 05 43 35 30 34 29 26 32 29 23 06 39 32 27 30 26 23 29 26 23 07 36 29 24 27 23 20 27 23 20 08 34 26 22 25 21 18 24 21 18 09 32 24 20 23 19 16 23 19 16
10 30 22 18 21 17 15 21 17 15
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1985. 2269. 2503. 55 1779. 2216. 2535. 65 1452. 2094. 2359. 75 1174. 1516. 1675. 85 643. 745. 778.
0
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 800 800 800
5 794 796 798 76
15 754 766 780 217
25 684 712 741 329
35 591 638 682 399
45 476 544 600 417
55 346 431 493 380
65 208 300 338 283
75 103 133 147 137
85 19 22 23 27
90 000
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 621 15.3 27.4 00-040 1020 25.2 45.1 00-060 1817 44.9 80.3 00-090 2264 55.9 100.0
90-180 0000 00.0 000.0
00-180 2264 55.9 100.0
0
Ordering Information
Explanation of Catalog Number. Example: CFA2GPF217120SO
Coffaire II:
Direct/
Indirect:
Recessed
with Perforated
Mesh Shield
CF
CN
A
Body Style:
A = Air Supply
and Return
Standard Coffaire II
For NYC Code –Local 3 Manufactured
2
Fixture
Width
G
Ceiling Type:
Standard Grid
P
Perforated
Lamp
Shield
Options/Accessories
Optional supply air slot cover: Order Catalog Number: CACS-2 Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. Chicago Plenum: SUFFIX: C. Dust Shield: See Folio Number: OA50-20
Specifications
Performance: In an installation of 2 lamp 40W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .64. To reduce glare the average brightness at 65° shall not exceed 1815 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 73.2%.
Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white
acrylic overlay.
F
Flat
White
Reflector
Lamp
Quantity
2=2 Lamp 3=3 Lamp
17
Lamp:
(By Others)
17=T8
(Nominal 24")
Voltage:
120, 277 or
UNV=120-277
Ballast Type:
1 or 2 Lamp Elec. T8 SO * H 1-3 Lamp Elec. T8 O3 * H3 * LOL Dimming T8 PS*
*Instant Start Standard Other dimming options. Consult factory.
NOTE: For T8 UNV, you must use H
<20THD <10THD
I
,H3, Ballast Code.
Specifications (continued)
Finish: Chassis exterior – soft white post painted polyester powder. Cavity –
soft white post painted polyester powder. Reflector – soft white post painted polyester powder, minimum 88% reflectance. Rust preventive undercoating.
Lamp Shield –white. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company
Section 5/Folio M15-36
Options:
Add appropriate suffix to catalog
no., ie: (GLR)