Coffaire II Recessed Fluorescent CFA2GPF2FT or 3FT
Page 1 of 2 Direct/Indirect – 2' x 2' with Perforated Basket
Features
• Direct/indirect lamp shield appearance with soft contoured interior.
• Perforated mesh lamp shield with white acrylic overlay.
• Contoured body and ends.
• Air supply and return.
• Air return slots located above lamp shield.
• Air return models meet UL 1598, Paragraph 9.2.2.5 requirements.
• 68.1% efficient (2 lamp TT5).
• 55.2% efficient (3 lamp TT5).
• Spacing to mounting ratio 1.4 (2 lamp).
• Spacing to mounting ratio 1.3 (3 lamp).
• Only 5" deep.
• Tension screws secure ends to body.
• Perforated lamp shield hinges from either side.
• Can be continuous row mounted.
• Built-in earthquake clips.
• Ballast accessible from room side.
• Optional supply air slot cover.
• Meets NYC Code.
• Construction to meet Chicago Plenum requirements is available.
Mounting Methods Dimensions
Air Supply and Return, 2 Lamp or 3 Lamp, Twin Tube T5
24"
exposed t-grid ceiling
lamp shield hinges either side
Exposed T-bar
by others
1-1/2"
max.
15/16"
Acoustical
material
by others
built-in earthquake clips
5"
(127mm)
24" (610mm)
2-1/2"
(64mm)
2" x 2-1/2" Access Plate
with 7/8" dia. K.O.
24" (610mm)
Job Information Type:
Job Name:
Cat. No.:
05/07
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 a Genlyte company
Section 5/Folio M15-26
Coffaire II Recessed Fluorescent CFA2GP2FT or 3FT
Page 2 of 2 Direct/Indirect – 2' x 2' with Perforated Basket
Air Supply and Return, 2 Lamp or 3 Lamp, Twin Tube T5
Model No. CFA2GPF2FT120SB
LER = FP - 56.2 IW - 65.5 BF - 0.86
Comparative yearly lighting energy cost per
1000 lumens = $4.27
Report Number: G2004033
Catalog Number: CFA2GPF2FT120SB
Lamps: F40 30BX/SPX35
Luminaire: Coffaire II with perforated
basket
Ballast: Triad C240SI120
Report is based on 3150 Lumens per lamp.
Efficiency: 68.1%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.4
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 22.920 22.920
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 74 71 68 66 64 62 64 62 60
02 67 62 57 58 54 51 56 53 50
03 61 54 48 51 46 43 49 45 42
04 56 48 41 45 40 36 43 39 36
05 51 42 36 40 35 31 39 34 31
06 47 38 32 36 31 27 35 30 27
07 44 34 28 33 28 24 32 27 24
08 41 31 25 30 25 21 29 24 21
09 38 29 23 28 23 19 27 22 19
10 36 26 21 25 21 17 25 20 17
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 3742. 4271. 4713.
55 3440. 4340. 4880.
65 2952. 4236. 4641.
75 2279. 3362. 3419.
85 1252. 1794. 1895.
0
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 1423 1423 1423
5 1416 1416 1417 135
15 1354 1369 1385 387
25 1242 1283 1331 593
35 1089 1168 1251 732
45 897 1024 1130 786
55 669 844 949 738
65 423 607 665 569
75 200 295 300 290
85 37 53 56 61
90 000
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 1115 17.7 26.0
00-040 1847 29.3 43.1
00-060 3370 53.5 78.6
00-090 4289 68.1 100.0
90-180 0000 0.0 000.0
00-180 4289 68.1 100.0
0
Model No. CFA2GPF3FT120X3
LER = FP - 41.2 IW - 111.1 BF - 0.88
Comparative yearly lighting energy cost per
1000 lumens = $5.85
Report Number: G2004247
Catalog Number: CFA2GPF3FT120X3
Lamps: F40/TT5
Luminaire: Coffaire II with perforated
basket
Ballast: UT340120
Report is based on 3150 Lumens per lamp.
Efficiency: 55.2%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.3
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 22.920 22.920
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 60 58 55 54 52 51 52 51 49
02 55 50 47 47 45 42 46 43 41
03 50 44 40 42 38 35 40 37 35
04 46 39 34 37 33 30 36 32 30
05 42 35 30 33 29 26 32 29 26
06 39 32 27 30 26 23 29 25 23
07 36 29 24 27 23 20 26 23 20
08 34 26 21 25 21 18 24 21 18
09 31 24 19 23 19 16 22 19 16
10 29 22 18 21 17 15 21 17 15
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 4588. 5247. 5781.
55 4093. 5117. 5785.
65 3308. 4788. 5255.
75 2484. 3407. 3715.
85 1354. 1658. 1692.
0
CANDELA DISTRIBUTION
0 1878 1878 1878
5 1848 1861 1878 177
15 1746 1789 1826 506
25 1582 1658 1726 766
35 1364 1479 1582 927
45 1100 1258 1386 966
55 796 995 1125 874
65 474 686 753 641
75 218 299 326 304
85 40 49 50 59
90 000
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 1449 15.3 27.8
00-040 2376 25.1 45.5
00-060 42316 44.6 80.8
00-090 5219 55.2 100.0
90-180 0000 00.0 000.0
00-180 5219 55.2 100.0
0
0.0 45.0 90.0 FLUX
Ordering Information
Explanation of Catalog Number. Example: CFA2GPF2FT120SB
Coffaire II:
Direct/
Indirect:
Recessed
with Perforated
Mesh Shield
CF
CN
A
Body Style:
A = Air Supply
and Return
Standard Coffaire II
For NYC Code – Local 3 Manufactured
2
Fixture
Width
G
Ceiling Type:
Standard Grid
P
Perforated
Lamp
Shield
Options/Accessories
Optional supply air slot cover: Order Catalog Number: CACS-2
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF.
Drywall Kit: Order Catalog Number: FK92X2.
Electrical Wiring Options: Consult factory.
Chicago Plenum: SUFFIX C.
Dust Shield: See Folio Number: OA50-20
Specifications
Performance: In an installation of 2 lamp 40W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .71. To reduce glare the average brightness at 65° shall not exceed
4641 candelas per square meter. To control veiling reflections, luminaire output
in the 30°-90° zone shall not be less than 74.0%.
Materials: Chassis parts are die-formed code gauge steel.
Lamp Shield: 22 gauge steel perforated mesh lamp shield with white
acrylic overlay.
F
Flat
White
Reflector
Lamp
Quantity
2=2 Lamp
3=3 Lamp
FT
Lamp:
(By Others)
Voltage:
120, 277 or
UNV=120-277
1-2 Lamp Elec. TT5
(40 Watt)
1-2 Lamp Elec. TT5 PR **
(40 Watt)
1-3 Lamp Elec. TT5
(40 Watt)
LOL Dimming TT5 PB* –
*Instant Start Standard
**Program Start
Other dimming options. Consult factory.
NOTE: For TT5 UNV, you must use
Ballast Type:
Add appropriate suffix
to catalog no., ie: (GLR)
<20THD <10THD
IB *
I3 *
IB,I
3 or PR Ballast Code.
Specifications (continued)
Finish: Chassis exterior – soft white post painted polyester powder. Cavity –
soft white post painted polyester powder. Reflector – soft white post painted
polyester powder, minimum 88% reflectance. Rust preventive undercoating.
Lamp Shield –white.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp
locations.
Labels: I.B.E.W./UL and ULc Listed.
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 a Genlyte company
Section 5/Folio M15-26
Options: