Features
• Direct/indirect lamp shield appearance with soft contoured interior.
• Perforated mesh lamp shield with white acrylic overlay.
• Contoured body and ends.
• Air supply and return.
• Air return slots located above lamp shield.
• Air return models meet UL 1598, Paragraph 9.2.2.5 requirements.
• 63.8% efficient (2 lamp T8).
• 60.2% efficient (3 lamp T8).
• Only 5" deep.
• Tension screws secure ends to body.
• Perforated lamp shield hinges from either side.
• Can be continuous row mounted.
• Built-in earthquake clips.
• Ballast accessible from room side.
• Optional supply air slot cover.
• Meets NYC Code.
• Construction to meet Chicago Plenum requirements is available.
Mounting Methods Dimensions
Air Supply and Return, 2 Lamp or 3 Lamp T8
24"
exposed t-grid ceiling
lamp shield hinges either side
Exposed T-bar by others
1-1/2" max.
15/16"
Acoustical material by others
built-in earthquake clips
5"
(127mm)
24" (610mm)
2-1/2"
(64mm)
2" x 2-1/2" Access Plate with 7/8" dia. K.O.
48" (1219mm)
Job Information Type:
Job Name:
Cat. No.:
05/07
Lamp(s):
Volts/Ballast:
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company
Section 5/Folio M15-56
Coffaire II Recessed Fluorescent CFA2GPF232 or 332
Page 2 of 2 Direct/Indirect – 2' x 4' with Perforated Basket
Air Supply and Return, 2 Lamp or 3 Lamp T8
Model No. CFA2GPF232120SO
LER = FP - 54.7 IW - 58.0 BF - 0.87 Comparative yearly lighting energy cost per
1000 lumens = $4.39
Report Number: G2004255 Catalog Number: CFA2GPF232120SO Lamps: F32/T8 TL841 Luminaire: Coffaire II with perforated
basket Ballast: Triad B232IUNV-HP, 58 watts Report is based on 2850 Lumens per lamp.
Efficiency: 63.8% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.920 22.920
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 69 66 63 62 60 58 59 58 56 02 63 57 53 54 50 47 52 49 46 03 57 50 45 47 43 39 45 42 39 04 52 44 38 42 37 33 40 36 33 05 48 39 33 37 32 29 36 32 28 06 44 35 29 33 29 25 32 28 25 07 41 32 26 30 25 22 29 25 22 08 38 29 23 28 23 19 27 23 19 09 35 27 21 25 21 18 25 20 17
10 33 25 19 24 19 16 23 19 16
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1512. 1734. 1897. 55 1394. 1771. 1994. 65 1217. 1800. 2093. 75 0974. 1715. 1353. 85 0612. 0711. 0777.
0
CANDELA DISTRIBUTION
0.0 45.0 90.0 FLUX
0 1179 1179 1179
5 1172 1174 1176 112
15 1120 1135 1151 321
25 1028 1067 1105 492
35 899 972 1031 606
45 742 851 931 651
55 555 705 794 618
65 357 528 614 504
75 175 308 243 281
85 37 43 47 52
90 000
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 925 16.2 25.4 00-040 1531 26.9 42.1 00-060 2800 49.1 77.0 00-090 3636 63.8 100.0
90-180 0000 0.0 000.0
00-180 3636 63.8 100.0
0
Model No. CFA2GPF332120O3
LER = FP - 50.7 IW - 85 BF - 0.88 Comparative yearly lighting energy cost per
1000 lumens = $4.73
Report Number: G2004256 Catalog Number: CFA2GPF332120O3 Lamps: F32T8 TL841 Luminaire: Coffaire II with perforated
basket Ballast: SYL QT3X32T8 120, 89.0 watts Report is based on 2850 Lumens per lamp.
Efficiency: 60.2% CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.920 22.920
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 66 63 60 59 57 55 56 55 53 02 59 54 50 51 48 45 49 46 44 03 54 48 43 45 41 38 43 40 37 04 49 42 37 40 35 32 38 35 31 05 45 37 32 36 31 27 34 30 27 06 42 34 28 32 27 24 31 27 24 07 39 30 25 29 24 21 28 24 21 08 36 28 23 27 22 19 26 22 19 09 34 25 20 24 20 17 24 20 17
10 32 23 19 23 18 15 22 18 15
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2192. 2472. 2669. 55 2012. 2469. 2720. 65 1718. 2427. 2758. 75 1358. 2193. 1865. 85 843. 959. 1041.
0
CANDELA DISTRIBUTION
0 1733 1733 1733
5 1722 1725 1729 164
15 1645 1668 1693 472
25 1507 1563 1613 720
35 1316 1412 1483 879
45 1076 1213 1310 930
55 801 983 1083 863
65 504 712 809 682
75 244 394 335 369
85 51 58 63 72
90 000
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
00-030 1356 15.9 26.3 00-040 2235 26.1 43.4 00-060 4027 47.1 78.2 00-090 5150 60.2 100.0
90-180 0000 00.0 000.0
00-180 5150 60.2 100.0
0
0.0 45.0 90.0 FLUX
Ordering Information
Explanation of Catalog Number. Example: CFA2GPF232120SO
Coffaire II:
Direct/
Indirect:
Recessed
with Perforated
Mesh Shield
CF
CN
A
Body Style:
A = Air Supply
and Return
Standard Coffaire II
For NYC Code – Local 3 Manufactured
2
Fixture
Width
G
Ceiling Type:
Standard Grid
P
Perforated
Lamp
Shield
Options/Accessories
Optional supply air slot cover: Order Catalog Number: CACS-4. Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X4. Electrical Wiring Options: Consult factory. Chicago Plenum: SUFFIX: C. Dust Shield: See Folio Number: OA50-20
Specifications
Performance: In an installation of 2 lamp 32W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .66. To reduce glare the average brightness at 65° shall not exceed 2093 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.6%.
Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white
acrylic overlay.
F
Flat
White
Reflector
Lamp
Quantity
2=2 Lamp 3=3 Lamp
32
Lamp:
(By Others)
32=T8
(Nominal 48")
Voltage:
120, 277 or
UNV=120-277
Ballast Type:
1 or 2 Lamp Elec. T8 SO* H 1-3 Lamp Elec. T8 O3* H3*
LOL Dimming T8 PS* *Instant Start Standard Other dimming options. Consult factory.
NOTE:
For T8 UNV, you must use H Ballast Code.
<20THD <10THD
I
, H3
Specifications (continued)
Finish: Chassis exterior – soft white post painted polyester powder. Cavity –
soft white post painted polyester powder. Reflector – soft white post painted polyester powder, minimum 88% reflectance. Rust preventive undercoating.
Lamp Shield –white. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company
Section 5/Folio M15-56
Options:
Add appropriate suffix to catalog
no., ie: (GLR)
I*
Loading...